Performance/execution

Product number: 110200
GTIN: 4068823005721
Measurement parameters: Carbonate hardness
Measuring range: 89,5 – 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)
Application: Alkalinity of open cooling circuits
Menu navigation: German, English, French
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.

Leasing Example

196,03 € non-binding
Monthly Rate (60 Rates)
Prices excl. VAT

Further rate options by choosing the payment method Leasing

Product information "Titromat® KH"
The Titromat® KH is used for the automatic determination and monitoring of the carbonate hardness at high hardness measuring ranges.

The Titromat®-Geräte KH, M1, M2 und TH are based on the technology, the performance profile and technical basic data of the Testomat 2000®.
Application:
  • alkalinity of open cooling circuits

Dimensions

Weight

Weight 11 kg

Other attributes

Country of origin DE
Customs tariff number 90278990
Technical specifications
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa 
Weight: approx. 9,5 kg
Menu Language: German, English, French
Measuring range:Carbonate hardness: 89,5 – 2685 ppm (Resolution: 89,5 ppm) | 35,8 - 1074 ppm (Resolution: 35,8 ppm) 

We recommend our reagents, as well as the following accessories

Titromat® TC 2060 Reagent A 500 ml
Product number: 155176
The 500 ml-bottle of original Titromat® TC 2060 Reagent A can be used immediately in the Titromat® KH without cumbersome filling and refilling. resolution: 2 °dH Measuring range: Carbonate hardness: 89,5 - 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)

€390.56*
Titromat® TC 2060 Reagent B 500 ml
Product number: 155177
The 500 ml-bottle of original Titromat® TC 2060 Reagent B can be used immediately in the Titromat® KH without cumbersome filling and refilling.   resolution: 2 °dH   Measuring range:   Carbonate hardness: 89,5 - 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)  

€390.56*
Titromat TC 2150 reagent A, 500 ml
Product number: 155178
The 500 ml bottles of the original Titromat TC2150 Reagent A can be used immediately without cumbersome decanting into the Titromat KH.

€408.77*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€160.17*
outlet hopper cpl. T2000/ECO
Product number: 40315

€110.19*
Current Interface SK 910
Product number: 270305
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments.   Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation   Usable in following devices: Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3,  Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2  