Contains: 2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 100 ml bottle1 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
Annual Service Set Professional for Testomat® 808 Professional maintenance package for the annual care of your Testomat® 808 device The Annual Service Set Professional is designed for the regular and professional maintenance of your Testomat® 808. It includes all relevant wear parts that are recommended to be replaced annually. The set contains: 2 x Sight glasses 30 x 3 3 x Flat gasket 24 x 2 1 x Insert for screw cap and suction tube for 500 ml bottle 1 x Cleaning brush set Professional maintenance package for the annual care of the Testomat® 808 The Annual Service Set Professional for the Testomat® 808 has been specially assembled for the recommended annual maintenance of the device. It contains all relevant wear parts that should be replaced during the yearly service to ensure a permanently reliable measurement function. By planned replacement of these components, measurement deviations, malfunctions, and unplanned downtime can be avoided. The service set thus supports a stable and safe operation of the Testomat® 808 over the long term. Benefits of the Annual Service Set Professional for the Testomat® 808 The Annual Service Set enables structured and efficient maintenance, as all required spare parts are included in one package. Wear parts such as sight glasses, gaskets, and the insert for screw cap and suction tube can be replaced without additional spare part procurement. The included cleaning brush set allows thorough cleaning of the measurement chamber and helps maintain consistently high measurement accuracy. Overall, the service set supports economical, preventive maintenance and extends the service life of the Testomat® 808 device.
The cleaning brush sets are equipped with a sun head so that you can clean the measuring chamber faster and more thoroughly. In addition, the brushes absorb the dirt better thanks to their dense bristles.[#dspacer#][#dspacer#]Consist:1x #895218 cleaning brush Ø 6mm1x #895219 cleaning brush Ø 16mm 1x #895220 cleaning brush Ø 20mm
Repair and Service Kit for Testomat® 808 from Heyl Complete Set for Maintenance, Repair, and On-Site Spare Part Supply The Testomat® 808 repair and service kit contains all essential wear and spare parts for efficient maintenance of your Testomat® 808 device. Ideal for service teams performing repairs directly at the customer site or in the facility. The kit includes all components necessary for repairs and maintenance. The kit contains: 8x O-Ring 3.68 x 1.78 8x O-Ring 1.78 x 1.78 8x O-Ring 4.5 x 1.5 8x Flat Gasket 24 x 2 1x Pump Head 4x 500ml Container with Screw Cap 1x 100ml Container with Screw Cap 1x Cleaning Brush Set 4x Elbow Screw Connectors 6x Fuse, T 0.1 A 6x Fuse, T 0.2 A 6x Fuse, T 1.0 A 6x Fuse, T 4 A 6x Sight Glass 30x3 2x Pipe, L = 53 mm 2x Pipe, L = 140 mm 1x Optical Board 1x SUB-D Null Modem Cable 1x USB-Serial Adapter 2x Dosing Needle 4x Hose Adapter 2x Magnetic Stirring Core 8x Screws M3x12 4x Screws M3x40 1x LED Holder 1x Solenoid Valve 1x Documentation/Software Complete Solution for On-Site Maintenance, Repair, and Service The Testomat® 808 repair and service kit was specifically designed for fast and professional device maintenance. It includes all relevant spare and wear parts needed for routine maintenance, repairs, or unplanned service calls. Thanks to its comprehensive contents, the kit is ideal for service teams, maintenance staff, and operators performing repairs directly at the customer site or facility. This minimizes downtime and ensures the Testomat® 808 remains fully operational at all times. Advantages of the Repair and Service Kit for Testomat® 808 The service kit enables efficient and structured maintenance because all necessary spare parts are bundled in a single set. In addition to gaskets, fuses, and hoses, the kit also includes key components such as the pump head, solenoid valve, optical board, and other essential accessories for the Testomat 808. This allows for rapid troubleshooting and repair without the need for additional spare parts, significantly reducing service times and supporting economical operation. Regular maintenance with original parts ensures high measurement accuracy and long-term operational reliability of the Testomat® 808.
Contents: 1 x 37570 Solenoid valve complete Testomat® 808 2 x 37580 Insert with screw cap and suction tube 100ml bottle 1 x 37859 double pump head Testomat® 808 1 x 31972 SUB-D null modem cable, 9-pin, 2 x socket, 3m 4 x 37579 Insert with screw cap and suction tube 500ml bottle 2 x 40050 Magnetic stirring core 4 x 37538 Tube adapter Testomat® 808 4 x 40157 Angle screw-in connector, G1/8"-6 2 x 37543 Pipe, PE, D=6 d=4 L=53mm 2 x 37544 Pipe, PE, D=6 d=4 L=140mm 6 x 40170 Viewing window 30x3 6 x 31595 Fuse solder-in, TR5, T0,1A 6 x 31592 Fuse solder-in, TR5, T1,0A 6 x 31584 Fuse, solder-in, TR5, T0.2A 6 x 31585 fuse, T0,315A 8 x 33797 O-ring 3,68 x 1,78 8 x 31666 Fuse G-, 5x20mm, T4A 8 x 33777 Flat gasket 24x2 EPDM 70 4 x 33253 Screw M3x40, A2, DIN 965 8 x 33246 pan-head screw M3x12 DIN 7985H A2 8 x 11264 O-ring 4.5 x 1.5 8 x 11245 O-ring 1,78x1,78 1 x 32286 Adapter USB > Serial -length 1.1 meter 1 x 32287 Cleaning brush set 1 x 37498 USB stick with software tool for T808 and maintenance manual 2 x 37621 Dosing needle Testomat® 808 completeTranslated with www.DeepL.com/Translator (free version)
Service Set Professional for 2-Year Maintenance of Testomat® 808 The Service Set Professional ensures maintenance of your Testomat® 808 for 2 years. All relevant wear and replacement parts are included in this set. Complete Maintenance Set for Testomat® 808 The Service Set Professional ensures that your Testomat® 808 operates reliably and accurately over a period of two years. The set includes all relevant wear and replacement parts needed for regular maintenance, enabling professional and scheduled care of the device. Scope and Benefits of the 2-Year Maintenance Package The maintenance set is specifically tailored to the requirements of the Testomat® 808 and includes both mechanical and functional replacement parts. Timely replacement of sight glasses, gaskets, pump and drive components increases measurement reliability and reduces unplanned downtime. Additional cleaning tools support proper care of the device throughout the maintenance period. Comprehensive Maintenance Package for Professional Care Over Two Years for the Testomat® 808 by Heyl This set consists of: 2 x Sight glasses 30 x 3 3 x Flat gasket 24 x 2 1 x Insert for screw cap and suction tube 500 ml bottle 1 x Pump head Testomat® 808 1 x Gear motor 2 x Hose adapters 1 x Cleaning brush set
Service set contains:2 x sight glasses 30 x 33 x flat gasket 24 x 21 x insert for screw cap & suction tube 100 ml bottle1 x insert for screw cap & suction tube 500 ml bottle1 x double pump head conversion kit1 x gear motor2 x Hose connector1 x Cleaning brush set Important: After replacement, the pump must be recalibrated in Testomat® 808 SiO2.The adjustment is available from firmware version T808_83-003. Carry out a firmware update for older versions before performing the adjustment! (Serial number less than 253.061)For this calibration, it is important that you use water with a silicate content of 0 ppm, otherwise the zero point calibration will be incorrect and lead to false measurement results.To ensure this, please use the silicate filter cartridge specially developed for this process for the T808 SiO2, article 270344.(For additional information and instructions on the equipment you need for the software update, please refer to the operating instructions. The instructions "Replacing the pump head on Testomat® 808 SiO2" are also available)
Service Set for Testomat® 808 – Maintenance Spare Parts Complete Maintenance Kit for Regular Care The service set for the Testomat® 808 contains all the essential spare parts for maintaining your device. This set includes: 15 x Flat gasket 24 x 2 6 x Sight glass 30 x 3 6 x O-ring 3.68 x 1.78 6 x O-ring 4.5 x 1.5 6 x O-ring 1.78 x 1.78 1 x Pipe, PE, D=6 d=4 L=53mm 1 x Pipe, PE, D=6 d=4 L=140mm 1 x Cleaning brush set Complete Maintenance Kit for Regular Care of the Testomat® 808 Hardness The service set for the Testomat® 808 contains all essential spare and wear parts required for regular maintenance and care of the device. By regularly replacing gaskets, sight glasses, and pipes, measurement deviations and malfunctions can be prevented early. This kit is ideal for operators and service teams who want to ensure the long-term operational reliability, measurement accuracy, and lifespan of their Testomat® 808. Advantages of the Service Set for Testomat® 808 The service set enables fast and structured maintenance, as all necessary spare parts are available in one package. Wear parts such as O-rings, flat gaskets, and sight glasses can be replaced without additional spare part procurement, reducing downtime. Additionally, the included cleaning brush set ensures thorough care of the measurement chamber and contributes to consistently high measurement quality of the Testomat® 808. The service set supports cost-effective and preventive maintenance.
Dear customers, please note that the calibration of the Testomat® 808 SiO2 can only be carried out with silicate-free water. Therefore, please use the silicate filter cartridge specially developed for this purpose when replacing the double pump head (art. no. 40395) and the associated pump adjustment.The cartridge filled with the special resin is inserted into the sampling line of the unit before the inlet and removed again after the adjustment. The pump replacement instructions describe the use of the silicate filter, storage conditions and shelf life. After the first use, the filter can be used up to 10 times within one year for balancing. After one year, the filter must be disposed of.