Spare Parts for TESTOMAT 808 / 808 SiO₂ – Reliability for Your Water Analysis Devices
For the long-lasting and trouble-free use of your water analysis devices from the TESTOMAT 808 and 808 SiO₂ series, HeylNeomeris offers a wide range of perfectly matched spare parts. Whether seals, service set filters, or electronic components – our spare parts are optimally tailored to the Testomat 808 models, ensuring reliable operation and easy maintenance.
Rely on high-quality original parts as well as compatible spare parts and service kits for 1- and 2-year maintenance, which ensure maximum operational reliability and precision for Heyl testers.
- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
In this adapter set are all parts included, that you need to install a Testomat® 808. Connection set consisting of: plastic hose 6/4 x 1.5 m length reduction 10 t0 6 mm shutoff 3/8" to 6 mm Frequently asked questions What do I need the connection set for? For quick connection of your Testomat® 808 to the water supply. What is included in the set? A hose, a reducer, and a shut-off valve. Do I need to buy additional accessories? No, everything for the connection is already included. Is the installation complicated? No, the components are easy to connect and quickly assembled. Can I also use the set for an exchange? Yes, ideal for replacing old or defective connectors. What advantage do I have in everyday life? A quick, secure connection without having to search for the right parts. Is the set ready to use immediately? Yes, it can be used directly after connecting.
Suitable for: Testomat 2000® Testomat ECO® Testomat® EVO TH Titromat® Testomat® 808
Contains: 2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 100 ml bottle1 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
Annual Service Set Professional for Testomat® 808 Professional maintenance package for the annual care of your Testomat® 808 device The Annual Service Set Professional is designed for the regular and professional maintenance of your Testomat® 808. It includes all relevant wear parts that are recommended to be replaced annually. The set contains: 2 x Sight glasses 30 x 3 3 x Flat gasket 24 x 2 1 x Insert for screw cap and suction tube for 500 ml bottle 1 x Cleaning brush set Professional maintenance package for the annual care of the Testomat® 808 The Annual Service Set Professional for the Testomat® 808 has been specially assembled for the recommended annual maintenance of the device. It contains all relevant wear parts that should be replaced during the yearly service to ensure a permanently reliable measurement function. By planned replacement of these components, measurement deviations, malfunctions, and unplanned downtime can be avoided. The service set thus supports a stable and safe operation of the Testomat® 808 over the long term. Benefits of the Annual Service Set Professional for the Testomat® 808 The Annual Service Set enables structured and efficient maintenance, as all required spare parts are included in one package. Wear parts such as sight glasses, gaskets, and the insert for screw cap and suction tube can be replaced without additional spare part procurement. The included cleaning brush set allows thorough cleaning of the measurement chamber and helps maintain consistently high measurement accuracy. Overall, the service set supports economical, preventive maintenance and extends the service life of the Testomat® 808 device. Frequently asked questions Are there any differences between service sets for the Testomat 808 and the Testomat 808 SiO2? Yes, as they do not automatically have the same spare parts. More detailed lists can also be found in the respective operating instructions under ‘Spare parts lists’. What are service sets for? They are designed to enable regular maintenance and minor repairs to be carried out independently. Regular servicing can significantly increase the service life of your Testomat. What does the service set or maintenance kit contain? The exact contents of the service sets and maintenance kits can be seen in the pictures or in the item descriptions listed in the shop. Can individual components also be ordered? Yes, that is possible. Please send us the item numbers or the exact item description by email: vertrieb@heylneomeris.de Can I also order a service set or maintenance kit and have the service carried out by a service partner? Yes, this is possible. Please let us know the exact location of the Testomat device so that we can find the service partner for your region. HeylNeomeris has a Germany-wide service partner network as well as service partners in Austria.
Bolt M 3x40, A2 DIN 965 for Testomat® measuring chamber. Spare part for our devices Testomat 2000® / ECO®, Titromat® und 808.
Insert with screw cap and suction tube Tube olive 2.4mm and a 100 ml bottle for Testomat® 808
Insert with screw cap and suction tube Tube olive 2.4mm for 500 ml bottle for Testomat® 808
Insert with screw cap and suction tube Tube olive 3.5mm for 500 ml bottle for Testomat® 808 SiO2, Testomat 2000® PO4,Testomat 2000® Polymer as well as Testomat® LAB CL.
Candle filter housing complete for Testomat® 808 / Testomat 2000® / Testomat ECO® candle filter with filter insert for filtering sample water before analysis max. pressure: 4 bar / 58 psi at 40°C (104°F), max. 10 bar / 145 psi at 20°C (68°F) max. temperature: 40°C / 104°F filter fineness: 100μm 1/4" inlet/outlet 1/8" drain with plug Frequently asked questions What do I need the candle filter for? It filters the sample water and protects the device from contamination. The candle filter is exclusively designed for filtering liquids. For which devices is the filter suitable? For Testomat® 808, Testomat 2000® and Testomat ECO®. Why is filtering water important? Clean water ensures more accurate measurement results and fewer disruptions. How finely does the candle filter filter? It retains particles up to a size of one hundred micrometers (100 µm). Do I need to change the filter regularly? Yes, the cartridge should be replaced if it becomes dirty. The filter insert should be changed at least once a year. Item number: 37584 Filter insert for candle filter Testomat 808. Is the installation complicated? No, the filter can be easily integrated into the pipeline. What advantage do I have in the operation? Less downtime and a longer lifespan for the device.
Conversion kit for converting the water connection from Testomat® BOB to Testomat® 808. Consisting of:1x Plug nipple G1/4" DN61x Pipe, PE, D=6 d=4 L=5m1x screw-in connector G1/4"-6
Dosing needle for measuring chamber TESTOMAT®808
ID=1.6mm complete2x screws M3x40, M3x501x shaft extension1x spacer plate1x double pump head with hoses1x hose extension1x 1.5 mm Allen keyImportant:After replacement, the pump must be recalibrated in Testomat® 808 SiO2. The adjustment is available from firmware version T808_83-003. Update the firmware of older versions before carrying out the adjustment! (serial numbers lower 253.061)It is important to use water with a silicate content of 0 ppm for this adjustment, otherwise the adjustment of the zero point is faulty and leads to incorrect measurement results. To ensure this, please use the silicate filter cartridge for the T808 SiO2, article 270344, specially developed for this process.(For additional information and notes on the equipment required for the software update, see the operating instructions as well as the "Replacing the pump head in Testomat808 SiO2" document)
Spare part for candle filter housing of Testomat® 808 Frequently asked questions What do I need the filter insert for? It filters the sample water and reliably retains dirt particles. Filter fineness 100 μm. For which device is the use suitable? For the candle filter in the Testomat® 808, our article number is 37583. Why should I change the filter insert? A dirty filter can affect the measurement and reduce the flow rate. How often does the insert need to be changed? Depending on the water pollution and usage.The maximum service life of the filter elements depends on the respective application. Generally, a change is recommended when the maximum permissible differential pressure of the filter element is reached. This is usually 1.5 bar. Otherwise, the filter element should be changed at least once a year. Is the exchange complicated? No, the filter insert can be quickly and easily replaced. What advantage do I have in the operation? Clean water ensures stable and accurate measurement results.
Spare part for measure chamber of Testomat® devices: Flat gasket 24×2 EPDM 70Two flat gaskets are required for replacement in the measuring chamber.
The fuse T1,0 A is a spare part for Testomat 2000® / ECO® and Titromat®.
The motor and pump head have to change after 120 operating hours.You reach this at a analysis interval of 30 minutes after aprox. 2 years.It means, the motor have a service life of under one year at a interval of 10 minutes.You can't change the pump head only, as the charcoal pencil is worn.
Holder for sight glass windows of the measuring chamber in Testomat ECO®, EVO TH and TITROMAT.
Testomat® 808 spare part: Hose adapter 2.4mm