Testomat 2000 – Precise water hardness measurement
Precise online water hardness monitoring for maximum process reliability
The Testomat 2000 from Heyl is an automatic measuring device for water analysis that continuously measures water hardness. The device is reliable, easy to use and provides accurate measurement results for monitoring and controlling water softening systems, reverse osmosis systems or cooling circuits. Our customers are convinced of the exceptional durability of the Testomat device series and appreciate this quality feature of Heyl.
Why the Testomat 2000 from Heyl is so impressive
- Automatic measurement of actual water hardness values in real time
- Precise and efficient process control
- Measurement of a wide range of hardness and non-hardness parameters, e.g. carbonate hardness, m-value and p-values, sulphite, iron or phosphate
- Reliable results thanks to proven titration method
- Monitoring of two measuring points
- Easy operation and low maintenance
- Compatible with various control and monitoring systems
- Durable design for continuous industrial use
Impressive features of the Testomat 2000:
Monitoring two measuring points allows problems to be detected simultaneously and provides data from two critical points, simplifying process monitoring. Measured values can be transmitted to a control or monitoring system via a 4-20 mA signal. These can be transmitted continuously and in real time. Two adjustable limit values with potential-free contacts for warning signals or automatic switching. This triggers an alarm immediately if a limit value is exceeded.
Wide range of applications for the Testomat 2000
- Cooling and boiler water systems: Limescale deposits are prevented and the system is protected from damage.
- Chemical industry: Stable process conditions are guaranteed and deposits are prevented.
- Drinking water treatment: Compliance with quality standards is ensured and also enables precise control of the treatment process.
- Food and beverage industry: Cleaning and hygiene processes are optimised and consistent product quality is ensured.
- Pharmaceutical applications: The highest purity requirements are met and damage to the system is prevented.
Buy the Testomat 2000 online – your advantages in the shop
Large selection of accessories: Find the right original accessories and reagents for precise water hardness measurement.
3% online discount: Get a 3% discount on the Heyl product portfolio in our shop.
Device registration: Register your newly purchased device quickly and easily in your customer profile – this allows you to keep track of locations and warranty periods at all times.
Warranty extension: Extend the warranty for your new device from 24 to 36 months and secure automatic delivery of indicators or reagents.
Secure payment & fast shipping: Benefit from secure payment methods and reliable, fast shipping for your order.
Personal advice & technical support via our online service hotline: Our experienced team of experts will help you choose the right Testomat 2000 and provide you with expert advice. Thanks to our comprehensive network of service partners, you receive maintenance and support from a single source – reliably, quickly and directly on site.
- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
The Testomat® LAB TH devices determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water, here in a package for monitoring two measuring points. In view of the fact that the Testomat® LAB TH total water hardness analysers were developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you both Testomat® LAB TH analysis devices in combination with the NeoTecMaster®, which was specially developed by our company, as a complete solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by both Testomat® LAB TH to display the measured values, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with two Testomat® LAB TH Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portuguese Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Performance profil Testomat® LAB TH: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger: - Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start Optional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB TH devices NeoTecMaster instrument cover Frequently asked questions What is this package with two devices particularly suitable for? For simultaneous monitoring of two measuring points. Can I monitor both measuring points centrally? Yes, all values are displayed together in a clear manner. What does using two devices at the same time bring me? More control over various areas or processes. How are the measurement data from the two devices displayed? Together on a central display with history. Can I evaluate the two measuring points independently of each other? Yes, each measuring point is recorded and displayed separately. Is the system suitable for larger plants? Yes, especially with multiple water flows or processes. Can I also respond automatically with the system? Yes, controls can be implemented via relays. How does the system help me in daily operations? It provides a better overview and reduces manual effort.
230 V Process Water Analyzer for the Chinese Market – Testomat 2000 CN Reliable Water Quality Monitoring with Integrated SD Logger The Testomat 2000 CN with SD card data logger and 230 V power supply is a water analysis device for continuous monitoring of water quality. It measures key parameters such as water hardness, carbonate hardness, p-value, and minus m-value. With its Chinese-language menu, the device is specifically designed for use in the Chinese market. The integrated SD card stores measurement data and error messages directly. The standard TH2005 reagents comply with local market requirements for soft water. Integrated relays allow cooperation with external titration valves, while SD card data storage ensures clear documentation and convenient evaluation of measurement results. Market-specific reagents and a robust technical design ensure high reliability during continuous operation. Where can the Testomat 2000 CN be used? The Testomat 2000 CN is suitable for monitoring water quality in various applications: Boiler water Softened water Condensate circuit water Pharmaceutical water Tap water Groundwater The Chinese-language menu makes this device specifically suitable for use in Chinese-speaking regions. Features and Capabilities of the Testomat 2000 CN The device continuously monitors relevant water parameters and delivers real-time measurement results. The 230 V power supply allows easy integration into existing systems. Additionally, relay outputs and optional interfaces enable flexible connection to higher-level control and monitoring systems. Frequently asked questions What water values can the Testomat 2000 CN measure? Measurement parameters: water hardness, carbonate hardness, p-value, minus m-value What makes the integrated SD card so practical? It stores measured values and messages directly in the device. For which market was this model developed? The device was developed specifically for the Chinese-speaking market. How is the device powered? Through a 230-volt connection. Can I connect the device to other systems? Yes, relay outputs and optional interfaces ensure flexible connection to higher-level control and monitoring systems. In which areas is the device used? The device continuously monitors relevant water parameters and provides real-time measurement results. Application areas: water treatment plants, water mixing plants, drinking water plants, softening plants, decarbonization plants, desalination plants, boiler houses, cooling towers, etc. Is the device suitable for continuous use / BOB function? Yes, it is designed for reliable continuous operation. The device is designed for unattended operation (BOB function).
Online Monitoring of Total Chlorine and Water Hardness with the T 2000 THCL Testomat 2000 THCL – Online analyzer by Heyl with photometric chlorine measurement and automatic titration The Testomat 2000 THCL is part of the T 2000 device family from Heyl, designed for simultaneous online monitoring of total chlorine content and water hardness. Using the photometric DPD method, it reliably measures total chlorine in the range of 0–2.5 mg/l (ppm), while fully automatic titration determines water hardness from 0.25 to 2.50 °dH. The device combines photometric total chlorine measurement with fully automatic water hardness titration in a 230 V system. Integrated limit relays allow direct implementation of alarm and control functions, while optional interfaces enable extended external data recording via SD card data loggers or analog current interfaces (e.g., 0/4–20 mA). Features of the Testomat 2000 THCL It measures total chlorine using the proven DPD method and simultaneously determines water hardness via automatic titration. Two independently programmable limit contacts allow direct monitoring and control of external processes, while an optional interface card stores data for long-term documentation or process monitoring. Applications of the Testomat 2000 THCL Monitoring of reverse osmosis systems Protection of reverse osmosis membranes from scaling due to hardness and damage from excessive chlorine Monitoring of softening and chlorination units in drinking water systems Performance Profile of the Testomat 2000 THCL Two independently programmable limit contacts for monitoring and control; analysis results can be recorded via optional interface card (current interface SK910) for a point or strip chart recorder (0/4–20 mA) or SD-Card data logger Testomat 2000® Menu-guided operation and programming via plain text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 failed analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests Indicator consumption calculator Reagent consumption calculator Frequently asked questions What does the Testomat 2000 THCL® measure? It simultaneously monitors the total chlorine content and the water hardness in the water. How is the chlorine level measured? The chlorine level is determined photometrically using the proven DPD method. How does the device measure the water hardness? The water hardness is automatically determined by an integrated titration. Why is simultaneous measurement of chlorine and hardness useful? This allows important water parameters to be monitored at the same time and systems to be better protected. Where is the Testomat 2000 THCL® used? For example, in medical technology (dialysis), for protection against corrosion, for protection of reverse osmosis membranes, for monitoring of softening and chlorine gas systems in drinking water or swimming pool areas. Can I also save the measurement data externally? Yes, analysis result recording with optional plug-in card (SK910 current interface) for point or line recorder (0/4–20 mA) or SD-card data logger Testomat 2000®.
Testomat 2000 – Online Analysis Device for Water Hardness and Other Parameters Continuous water quality monitoring with automatic titration and flexible parameter selection The Testomat 2000 is a versatile analysis device for the continuous determination of key water quality parameters such as water hardness, carbonate hardness, p-value, and minus m-value. The process photometer operates fully automatically with a precise piston dosing pump and plain-text menu display, allowing measurement, analysis, and control without manual intervention. Individually selectable indicators enable different parameters and measurement ranges, while internal limit contacts ensure reliable monitoring and alarm functions. Depending on the selected indicator, the device measures residual hardness, total hardness, carbonate hardness, p-value, or minus m-value fully automatically via precise titration. Two independently programmable limit contacts support automatic control and alarm functions, while external control options such as range-dependent measurement triggering or versions with SD card data logger are available for documentation and process analysis. What functions does the Testomat 2000 from Heyl offer? It combines modern measurement principles with practical control and evaluation functions. By selecting different indicator types, it can be used in a wide variety of applications. Two freely programmable limit values with adjustable hysteresis support monitoring tasks, and optional interfaces expand the device for complete data recording or integration with control systems. Applications for the Testomat 2000 Hardness Monitoring water quality in water treatment, blending, and drinking water systems Monitoring and quality control of softening systems with or without blending Monitoring and quality assurance of decarbonization systems Prevention of acid intrusion in decarbonization systems Boiler monitoring of steam boilers Performance Profile of the Testomat 2000 Simple, menu-guided operation and programming via plain-text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, or p-value selectable via indicator choice Free choice of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator volumes: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests Frequently asked questions What parameters can the Testomat 2000® measure? Measurement parameters: water hardness, carbonate hardness, p-value and minus m-value How flexible is the device with different requirements? Very flexible due to the free choice of hardness units in °dH, °f, ppm CaCO3 or mmol/l. Does the device also take over control tasks? Yes, it can monitor processes and react automatically. Do I have to start measurements manually? No, the device works automatically or as needed. Is the device suitable for complex systems? Yes, it can be integrated into various systems in a versatile way. How does the device support process safety? Through continuous monitoring and automatic alarms. Does the device need to be constantly supervised? No, the Testomat 2000® is designed for unattended operation (BOB function).
Testomat 2000 Antox for Online Water Analysis with Reductant Dosing Precise Water Hardness and Parameter Monitoring The Testomat 2000 Antox is a specialized version of the Testomat 2000 with an additional pump for dosing a reductant. It was specifically designed to eliminate measurement interference caused by oxidizing substances. The additional pump doses the reductant directly into the measurement chamber before the analysis begins, ensuring that the subsequent measurement is conducted under stable conditions. The precise piston dosing pump guarantees high measurement accuracy. The extra reductant dosing pump removes measurement errors caused by oxidizing substances in the sample water chamber. The water analysis is then automatically carried out using the standard procedure, allowing reliable measurement of residual hardness, total hardness, carbonate hardness, p-value, and minus m-value. Adjustable analysis triggering in interval or dynamic mode, external control options, and freely programmable limit contacts ensure flexible integration. What functions does the Testomat 2000 Antox offer? The selection of different indicators allows measurement of various parameters, and the precise piston dosing pump ensures reproducible results. Analysis can be triggered automatically in timed intervals or dynamically. External water meter signals can be used for analysis triggering. Additionally, there are two independently programmable limit contacts for automatic control and alarm functions. Where can the Testomat 2000 Antox be used? Oxidizing agents – especially chlorine – are present in water in many technical, municipal, and industrial applications. Other application areas include: Cooling water circuits Process water treatment Food and beverage industry Chemical industry Performance profile of the Testomat 2000 Antox Easy menu-guided operation and programming via plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator Choice of hardness units in °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaust-dependent interval operation) Flow-dependent via water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for service request Frequently asked questions How does the Testomat 2000® Antox differ from the normal Testomat 2000®? He has an additional pump that doses a reducing agent to eliminate interference from oxidizing agents. How does the hardness measurement work with the Antox model? After the addition of the reducing agent, the hardness measurement proceeds normally and reliably. Do I need special solutions or accessories? Yes, the appropriate Antox solution is needed for the measurement. Is the device easy to use? Yes, the operation is intuitive, and the results are quickly and reliably readable. How long does a measurement take? The addition of the reducing agent and the water hardness measurement together take only a few minutes. How do I store the device and the Antox solution correctly? Store dry, clean and at room temperature, keep the solution well sealed.
Online Bromine Analyzer for Process Monitoring Continuous Br2 analysis with automatic reagent dosing and limit monitoring The Testomat 2000 Br2 is an online analysis device for continuous monitoring of bromine (Br2) levels. After a short reaction time of approximately one minute, it delivers precise results in the range of 0–5.6 mg/L (ppm). The device features two independently programmable limit contacts for monitoring and controlling external processes. Analyses can be triggered automatically at intervals or via external signals, while internal error documentation and a programmable maintenance interval ensure reliability. The Testomat 2000 Br2 is suitable for monitoring disinfectant dosing and quality assurance of water in technical systems. After automatic addition of reagents, the measurement result is displayed on a plain-text screen, and two limit contacts can be used for switching or alarm functions. External controls or water meter signals can influence the analysis triggering. Functions of the Testomat Two independently programmable limit contacts allow monitoring of critical bromine concentrations and integration into automated control processes. Additionally, the device can monitor two measurement points using external solenoid valves. Typical Applications Swimming pools and indoor pools Process water in industry Water treatment plants Food and beverage industry Why is bromine measurement important? Bromine is used as a disinfectant and is only effective within a narrow concentration range. Too low bromine levels lead to insufficient disinfection, while too high levels can cause material damage, irritation, and unnecessary chemical consumption. Continuous bromine monitoring ensures safe dosing, protects equipment, and guarantees consistent water quality in swimming pools, process water, and industrial water applications. Performance Profile of the Testomat 2000 Br2 Analysis via automatic dosing of 2 reagents Measurement result display after approx. 1 minute reaction time 2 independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What do I need the Testomat 2000® Br2 for? It reliably measures the bromine content in water, so that the dosage is correct. How quickly will I see results? The bromine value is displayed after about 1 minute. Can I set limit values? Yes, two limit values can be individually programmed, e.g. for alarm or control. Do I need a lot of time to operate it? No, the menu is clear and easy to understand. How exactly does the device measure? Very accurate, thanks to the precise dosing pump and fine measurement range resolution. Can I monitor multiple measuring points? Yes, monitoring two measuring points is possible. What reagents do I need to use? The specially adapted Testomat 2000® Brom Reagent Set (Article number: 156295).
Testomat 2000 CAL – Analysis Device with Calibration Function Reliable measurement of key water parameters with a water analysis device from Heyl The Testomat 2000 CAL is an online analysis device for the continuous monitoring of important water parameters such as total hardness, carbonate hardness, p-value, and minus m-value. With its integrated calibration function, the device ensures consistently precise measurement results. Freely definable limit values, switching outputs, and diagnostic functions support reliable process monitoring. Measurements can be triggered based on time or quantity, allowing the Testomat 2000 CAL to adapt flexibly to different plant concepts. Technical Features of the Testomat 2000 CAL The integrated calibration function increases measurement reliability and reduces manual intervention. Freely programmable switching outputs can reliably trigger warnings, dosing processes, or external control systems. The piston dosing pump ensures precise reagent dosing and consistent measurement results while requiring minimal maintenance. Where can the Testomat be used? Monitoring water quality in water treatment, blending, and drinking water systems Monitoring and quality assurance of softening systems with or without blending Monitoring and quality assurance of decarbonization systems Prevention of acid intrusion in decarbonization and desalination systems Performance Profile of the Testomat 2000 CAL Simple, menu-guided operation and programming via plain-text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator choice Free selection of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy due to precise piston dosing pump Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator volumes: 100 ml and 500 ml bottles Programmable maintenance interval for maintenance requests Frequently asked questions What makes the calibration function on the Testomat 2000® CAL special? It ensures precise and reliable measurement results on a permanent basis. What are the benefits of automatic calibration for me? Less manual effort and higher measurement reliability. Can I flexibly integrate the device into my system? Yes, through various tax and trigger options. How does the device support my everyday processes? It monitors values and controls processes automatically. How reliable is the measurement in continuous operation? Very stable due to precise dosing technology. For which applications is the device particularly suitable? For water treatment and quality monitoring in plants. Monitoring water quality, where calibration of the measuring device is important, e.g. pharmaceutical industry, etc.
Testomat 2000 CLF – Process Photometer for Free Chlorine Analysis Precise determination of free chlorine in water with the Testomat 2000 by Heyl The Testomat 2000 CLF is an automatic online process photometer for continuous monitoring of free chlorine content in water within a measuring range of 0–2.5 mg/l (ppm). In a wet-chemical measurement process, two reagents are automatically dosed, enabling photometric measurement of the chlorine value within a short reaction time. Two independently programmable limit contacts with adjustable hysteresis provide additional monitoring and control functions directly within the process. In addition to automatic interval measurements, external analysis triggering and quantity-dependent measurements via a contact water meter can be implemented. Technical Features of the Testomat 2000 for Free Chlorine Measurement The Testomat 2000 CLF features internal error documentation, optional interfaces for measurement value output (e.g. 4–20 mA or SD card data logger), and a programmable maintenance interval. By switching external solenoid valves, two measuring points can be monitored. Where can the Testomat be used? Monitoring of chlorination systems in drinking water or swimming pool applications Protection of reverse osmosis membranes Monitoring of chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLF Analysis using automatic dosing of two reagents Display of the analysis result after a reaction time of approximately 1 minute Two independently programmable limit contacts for monitoring and control tasks; recording of analysis results with optional plug-in card (current interface SK910) for point or line recorders (0/4–20 mA) or an SD card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) Adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What exactly does the Testomat 2000® CLF measure? It reliably measures the content of free chlorine in water. For which applications is the device suitable? For drinking water, swimming pools, and industrial water systems. For monitoring chlorine gas systems for drinking water/swimming pool water. For protecting reverse osmosis membranes. For monitoring chlorine-containing biocides and conditioning agents. How quickly do I receive a measurement result? The result is available after about a minute. Can I set limit values? Yes, limit values can be set individually. Is the operation complicated? No, the menu navigation is simple and easy to understand. Can I save or forward measurement values? Yes, possible via interfaces or data loggers. Can the device monitor multiple measuring points? Yes, monitoring two measuring points is possible.
Testomat 2000 CIO2 – Online Photometer for Chlorine Dioxide Monitoring Precise CIO2 measurement for water quality and process safety with Heyl technology The Testomat 2000 CIO2 is an online photometer for continuous monitoring of chlorine dioxide (CIO2) levels in water. It delivers reliable measurements up to approx. 4.7 mg/L within just a few minutes of reaction time. In a photometric process, two reagents are automatically dosed, and a precise concentration measurement is performed in a short reaction time. Results are available after approximately one minute. Two independently programmable limit contacts with adjustable hysteresis enable direct process monitoring and control, for example to trigger alarms or switch external devices. The piston dosing pump and internal diagnostic functions ensure high measurement accuracy. Technical Features of the Testomat 2000 CIO2 With a plain-text menu interface, programmable measurement intervals, and multiple freely adjustable limit contacts, the device provides a precise, stable, and versatile solution for continuous CIO2 (chlorine dioxide) monitoring. Additional functions such as external analysis triggering, quantity-dependent measurement, and internal diagnostics extend usability for complex process environments. Applications Drinking water supply Process water and industrial applications Swimming pools Food and beverage industry Performance Profile of the Testomat 2000 for Chlorine Dioxide Measurement Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 1 minute reaction time 2 independently programmable limit contacts for monitoring and control tasks; measurement recording with optional plug-in card (SK910 current interface) for a point or chart recorder (0/4–20 mA) or SD-card data logger Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval mode) Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions Why is chlorine dioxide measurement important at all? It helps to keep the water quality stable and safe. How does the device work in everyday life? It measures automatically and monitors the value permanently. Can I make settings on the device? Yes, settings can be made. Will man mir bei Abweichungen direkt Bescheid geben? Yes, the device can react automatically at limit values. Is the device suitable for continuous use? Yes, it is designed for continuous operation. Do I need a lot of maintenance or care? No, the operation is reliable and low-maintenance. Can I also use the device in complex systems? Yes, it is also suitable for demanding applications.
Testomat 2000 CLT – Online Photometer for Total Chlorine Monitoring Continuous analysis of total and free chlorine The Testomat 2000 CLT by Heyl continuously monitors total chlorine content in water. With automatic dosing of three reagents and menu-guided operation, it delivers precise measurements in the range of 0–2.5 mg/l. The device can be switched to free chlorine measurement when required, providing high flexibility. The wet-chemical measurement process of the Testomat 2000 CLT produces a color change in the sample, the intensity of which is measured photometrically to provide precise and reliable results. Two independently programmable limit contacts with adjustable hysteresis enable direct monitoring and control functions in the process. By switching external solenoid valves, two measuring points can be monitored. Technical Highlights of the Testomat 2000 Chlorine The Testomat 2000 CLT features intuitive operation and programming with freely selectable measurement intervals, external triggering options, or quantity-dependent measurement via contact water meter. Operation is performed via a plain-text display. High measurement accuracy is guaranteed by the precise piston dosing pump. Where can the Testomat 2000 CLT be used? Monitoring chlorination systems in drinking water Monitoring chlorination systems in swimming pool applications Protection of reverse osmosis membranes Monitoring chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLT Analysis using automatic dosing of 3 reagents Display of the analysis result after approximately 1 minute Two independently programmable limit contacts for monitoring and control tasks; result recording via optical plug-in card (current interface SK910) for point or line recorders (0/4–20 mA) or SD card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What exactly does the Testomat 2000® CLT measure? It reliably measures the total chlorine content in water. The device can be switched to free chlorine measurement if needed, which provides high flexibility. Can I also measure free chlorine? Yes, the device can be set to measure free chlorine. For which applications is the device suitable? For monitoring chlorination systems for drinking water/swimming pool water, for protecting reverse osmosis membranes, for monitoring chlorine-containing biocides and conditioning agents, etc. How quickly do I receive a measurement result? The result is available after about a minute. Can I set individual limit values? Yes, two limit values can be set flexibly. Is the operation easy to understand? Yes, the menu navigation is clear and easy to use.
Testomat 2000 CLT Self Clean – Analyzer with Self-Cleaning for Total Chlorine Continuous Total Chlorine Analysis with Automatic Measuring Chamber Cleaning for Reliable Water Quality Control The Testomat 2000 CLT Self Clean is an analyzer for continuous monitoring of total chlorine in the range of 0.00 to 2.50 mg/l (ppm) in water, with an additional cleaning function for the measuring chamber. This ensures minimal maintenance effort. The device can also be switched to measure free chlorine in the same range (0.00 to 2.50 mg/l). By automatically dosing three reagents and using photometric measurement, the system delivers reliable results after a short reaction time. After a preset number of measurement cycles, the measuring chamber is automatically flushed and treated with a cleaning or disinfecting solution to prevent deposits or measurement interference. This improves long-term stability of the results and reduces maintenance requirements. Technical Highlights of the Testomat 2000 CLT Self Clean The device uses a photometric measurement method with automatic dosing of three reagents for precise determination of total chlorine. The plain-text display with menu-guided navigation allows easy configuration of measurement intervals, external triggers, quantity-dependent measurement modes, and threshold values. Two independently programmable limit values with hysteresis enable direct monitoring and control functions in the process. Applications of the Testomat 2000 CLT Self Clean Monitoring of chlorination systems in drinking water Monitoring of chlorination systems in swimming pools Protection of reverse osmosis membranes Monitoring of chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLT Self Clean Analysis via automatic dosing of 3 reagents Display of analysis results after a reaction time of approx. 1 minute Two independently programmable limit contacts for monitoring and control tasks; analysis recording with optional plug-in card (current interface SK910) for a point or strip chart recorder (0/4–20 mA) or SD-Card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy through precise piston dosing pump Analysis trigger: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 invalid analyses) and configurable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CrVI (High Measurement Range) – Analysis Device for Chromate and CrVI Extended analysis of chromate and CrVI for safe process monitoring The Testomat 2000 CrVI (High Measurement Range) is an analysis device for continuous monitoring of chromate and CrVI content in water with an extended measurement range (chromate up to 11.15 mg/L, CrVI up to 5.0 mg/L). Automated reagent addition and short reaction times provide fast and reliable results. The device allows continuous monitoring of chromate and CrVI. The photometric measurement method uses two automatically added reagents, ensuring reliable detection even at high concentrations. Measurement results are available within minutes. Two freely programmable limit values with hysteresis enable process alarms or control functions. Optionally, data can be recorded via 4–20 mA signal, recorder card, or SD-Card logger. Functional strengths of the T 2000 CrVI with extended measurement range from Heyl The device combines robust photometry with automatic reagent addition and provides precise measurement even at high concentrations. Easily programmable measurement intervals and short reaction times ensure efficient operation. Limit contacts allow direct process control or alarms, while optional interfaces enable seamless data logging. Typical applications of the online Testomat 2000 CrVI Monitoring chromate content in wastewater from electroplating facilities Monitoring wastewater in metalworking industries Performance profile of the T 2000 for chromate / CrVI measurement Analysis using automatic addition of 2 reagents Display of measurement result after approx. 2 minutes (measurement time without rinsing) Two independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What is the high measurement range of this device particularly suitable for? For applications with higher concentrations of chromate or Cr-VI. Does the device reliably detect heavy loads? Yes, it is designed specifically for higher values. How easy is it to operate during operation? Simply programmable measurement intervals and short reaction times ensure efficient operation. The device is easy to operate thanks to a menu-guided operation and programming via plain text display. Can I automatically trigger alarms or reactions? Yes, two freely adjustable limit values with hysteresis provide the possibility to trigger process alarms or control functions. How are the measurement values documented? Data can be documented optionally via 4–20 mA signal, recorder card or SD-card logger. Is the device also suitable for demanding industrial processes? Yes, it is designed for industrial applications. For example, to monitor the chromate content of wastewater in electroplating operations and to control wastewater in the metal processing industry. What distinguishes this model from the standard version? The significantly larger measuring range for higher concentrations.
Testomat 2000 CrVI (Standard) – Reliable Monitoring of Chromate and CrVI Reliable control of Chromate and Chromium VI in process water with the T 2000 from Heyl The Testomat 2000 CrVI (Standard) is an online analysis device for monitoring Chromate (CrO42-) concentrations from 0 to 2.0 mg/l or Chromium VI (CrVI) concentrations from 0 to 1.0 mg/l. It uses a photometric analysis method with automatic reagent addition and delivers results after a short reaction time directly for process control. The device operates with a photometric measurement principle, where two reagents are automatically dosed. After approximately two minutes of reaction time, the measurement results are available. Two independently programmable limit contacts allow direct integration into monitoring or control systems. Technical Features of the Testomat 2000 CrVI The photometric measurement principle combined with automated reagent addition distinguishes the Testomat 2000 CrVI. This allows reliable measurement of Chromate and CrVI. Measurement data can also be logged via optional interfaces. The clear-text menu simplifies configuration and operation. Typical Applications of the T 2000 CrVI Monitoring chromate content in wastewater from electroplating facilities Control of wastewater in the metalworking industry Why is Monitoring Chromate and Chromium VI Important? Chromium VI is highly toxic and subject to strict legal limits. Continuous monitoring of Chromate and CrVI allows early detection of limit exceedances, protects humans and the environment, and ensures compliance with environmental regulations in process and wastewater systems. Performance Profile of the Testomat 2000 CrVI Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 2 minutes of reaction time (excluding flushing time) 2 independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via clear-text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaustion-dependent interval operation) Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 faulty analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance request Frequently asked questions What is monitored with the Testomat 2000® CrVI? The chromate and chromium VI content in the water. Why is the measurement of chromium VI so important? Because chromium VI is harmful to health and has strict limits. How does a measurement work? The device automatically doses reagents and measures independently. How long does an analysis take? Display of the analysis result after a reaction time of approximately 2 or 3 minutes. Can I use the device to monitor wastewater? Yes, especially in metal processing and electroplating industries. Does the device help to comply with regulations? Yes, it supports the safe monitoring of limit values. Is the device suitable for continuous operation? Yes, it is designed for continuous monitoring.
Testomat 2000 DUO – Measurement of Key Water Parameters Heyl Testomat with two measurement points for analyzing various water parameters The Testomat 2000 DUO is an online analysis device that monitors two measurement points simultaneously, allowing parallel evaluation of different water parameters. Possible measured parameters include: Water hardness Carbonate hardness p-value (pH) Minus m-value The Testomat 2000 DUO expands the capabilities of traditional analysis devices by evaluating two measurement points at the same time. Automatic switching between measurement points reduces installation and operation effort, as no separate control unit is required. Measurement parameters are selected using easily replaceable indicators. Technical Strengths of the Testomat 2000 DUO The device uses automatic titration combined with a precise piston dosing pump, enabling exact measurements of different parameters at two measurement points. Various operating modes such as automatic intervals, external control, dynamic intervals, or volume-dependent measurements adapt the device to different plant configurations. Versatile Applications of the T 2000 DUO The Testomat 2000 DUO by Heyl is suitable for monitoring in water treatment, water blending, and drinking water systems. Please note that a Viton DosiClip is required for measuring carbonate hardness. This must be specified when ordering a DUO device. Performance Profile of the Testomat 2000 DUO Monitoring of 2 measurement points with different indicator types, e.g., water hardness with different measurement ranges or water and carbonate hardness Automatic measurement point switching Input to restrict to measurement point 1 available Menu-guided operation and programming with plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, p-value via indicator selection Choice of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause 0–99 minutes) External control Dynamic (exhaustion-dependent interval operation) Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 failed analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests Frequently asked questions What is special about the Testomat 2000® DUO? It monitors two measuring points at the same time and can analyze different water parameters in parallel. What water values can the device measure? For example, water hardness, carbonate hardness, p-value or the minus m-value. How does the device switch between measuring points? The Testomat switches automatically between the two measuring points. Do I have to install a separate device for each measuring point? No, a Testomat 2000® DUO can monitor two measuring points with just one device. How do I set which parameter is measured? The measurement parameter is set in the menu and determined by the appropriate indicator. Where is the Testomat 2000® DUO used? For example, in drinking water systems, water treatment or water mixing systems. Use in two circuits of different hardness. Measurement of input and output hardness. Can I set different measuring ranges? Yes, different measurement ranges can be selected depending on the indicator.
Testomat 2000 Fe – Real-Time Iron Measurement in Water Reliable iron monitoring for process water with the online analysis device T 2000 by Heyl The Testomat 2000 Fe is an online analysis device for the continuous determination of dissolved iron in water (iron-II + iron-III). It operates with automatic reagent dosing and photometric analysis, providing consistently stable and reliable measurement results. The Testomat 2000 Fe is used wherever iron concentration must be monitored to prevent deposits, discoloration, or disruptions in downstream processes. Through automatic analysis, the device regularly delivers current measurements, allowing early responses to rising iron concentrations. Limit exceedances can thus be detected immediately and used to trigger alarms or control actions. Technical Strengths of the Testomat 2000 Fe The Testomat 2000 Fe uses a photometric measurement method in which iron-II and iron-III are evaluated after automatic addition of defined reagents. The analysis is carried out using two reagents, and after a reaction time of approximately 7 minutes (pure measurement time without rinsing), the result is displayed. Measurements are performed independently at set intervals or via external triggers. Technical features include two independently configurable limit contacts and various signal outputs for further processing of measurement values. Internal diagnostic functions support safe operation and facilitate maintenance planning. Optional interfaces allow connection to process control systems or external data loggers. Applications for the Testomat 2000 Iron De-icing systems Monitoring of de-icing systems and well water Control of operational and drinking water streams Why Iron Measurement is Crucial in Water Treatment Dissolved iron is initially invisible in water but can lead to deposits, discoloration, and disruptions in downstream processes through oxidation. Even low concentrations cause fouling of filters, pipelines, and membranes. Continuous iron measurement enables early detection of limit exceedances, protects plant components, and ensures consistent water quality in process, operational, and drinking water applications. Performance Profile of the Testomat 2000 Fe Analysis using automatic dosing of two reagents Display of the measurement result after approximately 7 minutes (measurement time without rinsing) Two independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pauses adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What happens when there is too much iron in the water? It can cause deposits, discoloration and damage to equipment. How often does the device measure the iron level? Regularly automatically or controllable as needed. How long does a single measurement take? The result is available after about 7 minutes. Can I integrate the device into my system? Yes, it can be easily integrated into existing systems. Does the device help me avoid damage? Yes, it detects problems early and protects facilities. For which types of water is the device suitable? For process, service and drinking water. Monitoring of de-ironing systems and well water.
Testomat 2000 PO4 – Precise Online Phosphate Analyzer Continuous monitoring of ortho-phosphate, reliable and automated The Testomat 2000 PO4 is an analysis device that continuously and reliably monitors ortho-phosphate levels in the range of 0 to 10.0 mg/L (ppm). The measurement is based on molybdenum blue photometry. A chemical reaction produces a characteristic steel-blue color change in the sample. Two reagents are automatically added, and after a short reaction time of approximately ten minutes, the Testomat provides a precise result. With menu-guided operation, plain-text display, and selectable units (ppm or mg/L), the device is ideal for continuous monitoring tasks. Features of the Testomat With automatic reagent supply, programmable measurement intervals, and two independent setpoints with hysteresis, the device delivers accurate results at all times. Its compact design allows flexible installation directly at the measurement point. Digital interfaces enable seamless integration into existing control and monitoring systems. Where can the device be used? Process water monitoring Production water treatment Treated wastewater (wastewater treatment plants, biogas plants) Online environmental analytics Performance profile of the T 2000 PO4 from Heyl Analysis using automatic addition of 2 reagents Display of measurement result after approx. 10 minutes (measurement time without rinsing) Menu-guided operation and programming via plain-text display Selectable units in ppm or mg/L Analysis triggering: Automatic interval mode (interval pause adjustable from 0–255 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Frequently asked questions What is measured with the Testomat 2000® PO4? The Testomat 2000 PO4 is an analyzer that reliably and continuously monitors the content of ortho-phosphate in the range of 0 to 10.0 mg/L (ppm). How does the measurement work in the device? The measurement is based on molybdenum blue photometry. This produces a chemical reaction that causes a characteristic steel-blue color change in the sample. Two reagents are automatically dosed and after a short reaction time of about ten minutes, the Testomat delivers a precise result. How long does an analysis take? The analysis result is available after a reaction time of approximately 10 minutes. For which areas is the device particularly suitable? Monitoring of process water, treatment of production water, treated wastewater (sewage treatment plants, biogas plants), online environmental analysis. How often does the device measure the value? The interval can be set individually as needed. Can the operation be performed without technical knowledge? Yes, the operation is simple and well understood through a display. What does automatic measurement bring me in everyday life? You save time and keep an eye on the water quality permanently.
Testomat 2000 – Online Analysis Device for Polyacrylates Reliable online analyzer for monitoring polymer concentrations in water treatment The Testomat 2000 Polymer is an online analysis device for monitoring polyacrylate content in the range of 0 to 50 mg/L (ppm), with a standard product-specific factor of 1.00. The Testomat 2000 Polymer is a professional online analyzer for automatic analysis of polyacrylate content in water. Photometric measurement is based on the addition of two reagents. After a reaction time of approx. 7 minutes, the result is displayed digitally and can be used for control or documentation. With menu-guided operation, unit selection (ppm or mg/L), and versatile triggering options, the analysis process is efficient and reliable. It is suitable for monitoring conditioning agents in cooling and heating circuits. Technical Features of the Testomat 2000 Polymer Automatic interval measurements, external control options, and programmable switching functions allow adaptation to various process requirements. Two independent switching points with hysteresis, adjustable maintenance intervals, and internal error documentation increase reliability in continuous operation. Performance Profile of the T 2000 Polymer Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 7 minutes reaction time (measurement time without rinsing) Menu-guided operation and programming via plain-text display Selectable units in ppm or mg/L Analysis triggering: Automatic interval mode (interval pause adjustable from 0–255 minutes) External triggering Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Why is monitoring polyacrylates in water treatment important? Monitoring polymers ensures optimal dosing of conditioning agents, prevents deposits and fouling, and reliably protects water treatment equipment from operational disruptions. Chemical dosing must be monitored with a Testomat because its effectiveness is highly concentration-dependent. Continuous online monitoring ensures dosing stays within the optimal range, prevents under- or overdosing, and protects equipment, processes, and water quality reliably. Frequently asked questions What does the Testomat 2000® Polymer measure in water? The device is used to determine the polyacrylate content (anionic polyacrylates). Why is polymer control important? It prevents over- or under-dosing of chemicals. How does the device support the correct dosage? Through continuous measurement and reliable results. When can I expect the results of the test? Display of the analysis result after a reaction time of approximately 7 minutes. Can I adapt the device to my process? Yes, settings and measurement intervals can be flexibly selected. Where is the device typically used? For monitoring conditioning agents in cooling and heating circuits.
Testomat 2000 Self clean – Analyzer with Automatic Cleaning Water Hardness Meter from Heyl with Automatic Measurement Chamber Cleaning for Consistently Stable Results The Testomat 2000 Self clean is a specialized version of the Testomat 2000 with an additional dosing pump for adding a cleaning solution after analysis. After a set number of analyses, the measurement chamber is automatically rinsed and a cleaning solution is dosed to remove deposits in the measurement chamber and drain hose. The chamber content is discharged after a short reaction time, and the system is rinsed several more times. This ensures long-term measurement accuracy and device performance. The device measures various water parameters such as residual and total hardness, carbonate hardness, p-value, and minus m-value, with selectable units in °dH, °f, ppm CaCO3, or mmol/l. Special features of the Testomat 2000 Self clean With freely selectable hardness units, automatic interval control, and various external triggering options, the device can flexibly adapt to different measurement tasks. Two programmable limit values with hysteresis enhance process control, while the intuitive menu reduces operating errors and simplifies commissioning. Applications for the Testomat 2000 Self clean Boiler feed water Water treatment Cooling towers Swimming pools Functions and performance features of the Testomat 2000 Self clean Easy menu-guided operation and programming via plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator Choice of hardness units in °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaust-dependent interval operation) Flow-dependent via water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for service request Frequently asked questions What is special about the Testomat 2000® Self Clean? He cleans his measuring chamber automatically with a special cleaning solution after the analyses. Why is automatic cleaning useful? It removes possible contaminants in the measuring chamber and ensures reliable measurement results. How does the self-cleaning function work exactly? The measuring chamber is rinsed, cleaning solution is dosed, left to act for approximately 30 seconds and then thoroughly rinsed. Do I have to start the cleaning myself? No, the cleaning is done automatically after the set number of analyses. What solutions do I need for operation? For cleaning, use the Self clean solution, and for measurement, use a suitable Testomat 2000 indicator. Does cleaning affect the measurement? No, after cleaning, the measuring chamber is rinsed and the device continues to measure normally. Is the Testomat 2000® Self Clean difficult to maintain? No, the maintenance effort is significantly reduced by the automatic cleaning.
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified. It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® functionalities of both devices: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® EVO TH: High-precision titration by means of piston metering pump LCD graphic display Multilingual menu with easy switching (internal programming is retained) External clear / acknowledge input Free programmable password Range monitoring (fall below limit value1 / exceed limit value 2) Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure) Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 100 and 500 ml bottles Analysis trigger: automatic interval operation (0-99 minutes) depending on quantity via contact water meter Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover Frequently asked questions What does this EVO TH and LAB CL system measure simultaneously? Water hardness and chlorine levels in a combined system. What advantages does the Testomat® EVO TH offer compared to other devices? It is certified and particularly suitable for boiler systems. Our Testomat® EVO TH is approved for boiler houses | Component identification number: TÜV. WÜH. 21-025 | VdTÜV leaflet water monitoring device 100 and UL-TÜV certified. How does the system support compliance with regulations? Through proven technology and reliable monitoring. Can I centrally control and monitor both devices? Yes, via the NeoTecMaster® with a shared display. How are measured values and status messages displayed? Clearly on the integrated screen. Is the system also suitable for demanding industrial processes? Yes, it is designed for complex systems. How flexible is the system for future expansions? It can be expanded modularly at any time. What makes this package particularly attractive for operators? It combines proven safety with modern control systems.
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB CL in combination with the NeoTecMaster® Multi Channel Controller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input, in this case the RS232 interface, is used by the Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. Two modules that fundamentally expand the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portuguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover Frequently asked questions What exactly does this system monitor in the water? The level of free chlorine or total chlorine. How does the NeoTecMaster® help me in my operations? It collects all the data and displays it centrally. Can I control dosages with the system? Yes, processes can be adjusted via the outputs. How quickly will I receive a measurement? A result is available after a short time. How is reagent consumption optimized? The quantities are precisely calibrated. Can I adapt the system to my equipment? Yes, this is possible through modular expansions. How does the system support me in monitoring? It clearly displays values, trends, and messages. Can I share the measured values with other systems? Yes, easily done via interfaces.
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water and the Testomat® LAB CL is a robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB TH and Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you both Testomat® LAB analysis devices in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® LAB TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch; Portuguese Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Performance profil Testomat® LAB TH: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger: - Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly. Analysis trigger: Automatic interval operation (interval pause adjustable from 0-255 minutes) External analysis input (start/stop) Manual start Optional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB devices NeoTecMaster instrument cover Frequently asked questions What values does this premium package monitor simultaneously? Water hardness and chlorine levels in a system. Why is the combination of two devices useful? It allows for more comprehensive control of water quality. How are both measurement values displayed? Central on a shared display with history. Can I evaluate both devices at the same time? Yes, all data is collected in the controller. How quickly does the chlorine device deliver results? Already after about a minute. Is the system suitable for complex monitoring? Yes, especially for several important water parameters. Can I use the system for automatic responses? Yes, it can react directly to measured values. What is the biggest advantage of this package? More overview and control over several water values at the same time.
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water. In view of the fact that the Testomat® LAB TH was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB TH in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster®, in this case the RS232 interface, is used by Testomat® LAB TH to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB TH functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Proven performance profil: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger: - Automatic interval operation (interval pause adjustable from 0-255 minutes) - External analysis input (start/stop) - Manual start Optional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB TH NeoTecMaster instrument cover Frequently asked questions What does the value-added package with NeoTecMaster® bring me in concrete terms? You get measurement and central control in one system. How many measurement values can the NeoTecMaster® process at the same time? Up to four measurement signals in parallel. Can I view the history of my measurements? Yes, directly on the integrated display. Can the system be expanded later? Yes, can be flexibly extended with additional modules. Can I also control processes with the system? Yes, for example, via relays for automatic reactions. How are measurement data stored and used? They are stored and can be evaluated later. Is the system suitable for complex systems? Yes, especially for networked and larger applications. What is the advantage over a single device? More control, better overview and extended control options.