In this adapter set are all parts included, that you need to install a Testomat® 808. Connection set consisting of: plastic hose 6/4 x 1.5 m length reduction 10 t0 6 mm shutoff 3/8" to 6 mm
Contents: 1 x Screwdriver Torx TX10X80-3K 1 x screwdriver VDE-SZ-0,4X2,5X80 1 x water pump pliers 250MM 1 x flat round nose pliers 200MM
Candle filter housing complete for Testomat® 808 / Testomat 2000® / Testomat ECO® candle filter with filter insert for filtering sample water before analysis max. pressure: 4 bar / 58 psi at 40°C (104°F), max. 10 bar / 145 psi at 20°C (68°F) max. temperature: 40°C / 104°F filter fineness: 100μm 1/4" inlet/outlet 1/8" drain with plug
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen. Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"
Umrüstsatz für den Wasserzulauf zum Anschluss eines Gewebeschlauches, geeignet für Testomat 2000®-, Testomat ECO®- und Titromat®-Geräte. Inhalt: Schnellverschlussstecker 1/4" Schnellverschlusskupplung 1/4" auf Schlauch di=6 mm Verriegelung auf der Schlauchseite
Cooler consists of Titanium steel 1.4571 for automatic sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 546 x 128 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler made of titanium stainless steel 1.4571 for the automatic extraction of water samples up to 200°C hot water. Technical data:Max. hot water pressure: 40 barMax. Cold water pressure: 8 barMax. Max. hot water temperature: 0-200°C Connections:Cooling water (inlet and outlet): ½ ”Hot water (inlet and outlet): 8 mm Dimensions:546 x 128 mm Weight:2.3 kg Length of the cooling coil:5.1 metri Material:Titanium stainless steel AISI316Ti4, EN 1.4571(Wall bracket: AISI316L, EN 1.4404) Performance (example for analyzers):< 40°C with cooling water at a temperature of <25°C at a water flow of the sample water of approx. 23 L/h Classification of the liquids: Class 2 - non-hazardous liquids Classification of the coolant Dir 2014/68 UE PED: Class A
Cooler consists of Titanium steel 1.4571 for automatic sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 598 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for manual sampling to 120°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: ½ Cold water outlet (canal): ½ Hot water (in- and outlet): 8 mm Dimensions: 598 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Cooler consists of Titanium steel 1.4571 for for manual sampling to 80°C hot water. Max.water pressure/hot water: 16 bar Max.water pressure/cold water: 8 bar Connections: Cold water inlet: 8 mm Cold water outlet: ½ Hot water (in- and outlet): 8 mm Dimensions: 413 x 335 mm You can find a detailed description of the cooler in the technical data sheet for download on this page.
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation Usable in following devices: Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3, Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2
Recommended for Testomat® LAB instruments which are exposed to sunlight.
MEPUClip® pressure booster pump – buy online Reliable water supply for Testomat and Titromat devices The MEPUClip® pressure booster pump was specially developed for use in Testomat and Titromat devices and reliably ensures automatic filling of the measuring chamber system – even when the line pressure is too low or when suction is from open water systems. Whether in the laboratory, in water treatment or in industrial applications: with its robust design, durable technology and simple mounting on the top-hat rail, the MEPUClip® pump offers an efficient and safe solution for stable measuring processes. If you want to buy a low-maintenance and ready-to-use pressure booster pump, the MEPUClip® is the ideal choice. Areas of application for the MEPUClip® pressure booster pump This pressure booster pump is used wherever Testomat or Titromat devices require a stable water supply: Automatic filling of the measuring chamber system Use in environments with fluctuating or very low pipe pressure Measuring water intake from an open system The pump was designed for the Testomat 2000 and Titromat series and ensures precise and permanently reliable delivery of the measuring water. Advantages of the MEPUClip® pressure booster pump Ready for immediate use: factory-prepared – just connect and start Self-priming up to < 3 mWS Low maintenance for worry-free continuous operation Easy installation by snapping onto the top-hat rail Constant delivery rate of 0.6 l/min Robust construction for long operating times Optimised for Testomat and Titromat devices from Heyl Supports stable measuring conditions, even if the pressure in the water supply line is too low Important information for operation To ensure that the pump operates reliably, the following points should be taken into account: Keep the suction line as short as possible Extend flushing times if necessary Always check connections for leaks Keep hose lines clean Maintenance information The MEPUClip® is generally low-maintenance. Nevertheless, it is advisable to check the following regularly: Tightness of hose connections, screw connections, etc. Contamination in the hose lines This ensures that the delivery rate remains stable and the measurement quality is guaranteed throughout the entire operating time. Installation – quick and easy Installation is quick and easy: simply snap the MEPUClip® pressure booster pump onto the top-hat rail in the device – done. Why MEPUClip® – order online here? If you want to buy a powerful, durable and ready-to-use pressure booster pump that is perfectly matched to Testomat and Titromat devices, the MEPUClip® offers maximum reliability and precise delivery quality. Ideal for environments where the water supply pressure is too low or the sample water has to be drawn from an open system. Order the original spare part from Heyl directly from our online shop and benefit from fast availability, secure spare parts supply and reliable product quality. Get a 3% online shop discount on all Heyl items.
Data logger, developed for Testomat 2000® and ®Titromat with network connection for remote enquiry and maintenance. Technical DataThe network logger plug-in card for Testomat 2000® is a miniature computer with network connection, webserver, FTP server and integrated flash memory8 MB flash memory for 400000 measured values and notifications (over a period of 5 years)? Generation of one measuring and onealarm file per monthFiles are stored in CSV format and can be edited with a spreadsheet softwareDisplay the current measured values and the last alarm on a web browserGraphic display of the monthly measuring values on a web browserNotification of new measured values, alarms/notifications and limit values being exceeded via emailFile download by browser or FTPForwarding of all notifications and measured values to any TCP/IP port for linking systems with SPS and other network-enabled devicesPassword protection for all settings, FTP and web accessAuto-MDI-X
Plug-in card for connecting Testomat 2000® to a protocol printer via the serial interface RS232, suitable for Testomat 2000® and Titromat® instruments. Technical Data for connecting a log printer or protocol converter (field bus, Ethernet, etc.)