Skip to main content Skip to search Skip to main navigation

Silicate measurement for industrial water treatment and medical technology

Silicate measurement is a decisive factor for industrial water treatment and for sensitive applications in the medical environment. By reliably monitoring the silicon dioxide (SiO₂) content in water, you can prevent scale formation, corrosion, process disruptions and unnecessary downtime. This protects your systems and reduces operating costs in the long term.



Why silicate measurement?

  • Prevent hard, glassy deposits in boilers and turbines
  • Protect against corrosion and high repair costs
  • Ensure stable processes in RO and EDI systems
  • Compliance with relevant standards in the medical sector (DGSV, AKI)
  • Early fault diagnosis through continuous online monitoring

Buy silicate measuring devices and increase operational safety: Testomat® 808 SIO2

Typical areas of application

  1. Silicate measurement in boiler and boiler systems

    • Advantage: Protection of heat exchangers, turbines and steam generators. This is because silica/SiO₂ can form hard, sometimes glass-like deposits at high temperatures, which cause heat loss, corrosion and mechanical stress.
    • Benefits: Fewer deposits, lower maintenance costs, longer service life, corrosion prevention, avoidance of expensive downtimes thanks to suitable cleaning and downtime strategies.

Buy silicate measuring devices for boiler systems now: Testomat® 808 SIO2

  1. Power plant water treatment

    • Advantage: Online silicate monitoring in the feed water circuit.
    • Benefit: Minimized risk of scale, maximum operational reliability thanks to immediate detection of changes.

To the selection of online silicate analyzers: Testomat® 808 SIO2

  1. Before and after reverse osmosis (RO) and EDI modules

    • Benefit: Protection against fouling, clogging and membrane damage.
    • Benefit: Stable processes, protection of your systems during longer system downtimes.

Discover silicate measurement for RO/EDI systems: Testomat® 808 SIO2

  1. Industrial processes

    • Advantage: Continuous measurement enables optimum process control.
    • Benefit: Cost reduction through early detection of mixed bed exhaustion.

View process monitoring solutions now: Testomat® 808 SIO2

  1. Medical environment (AEMP, outpatient care centers or similar with sterile processing)

    • Advantage: Compliance with the limit values according to DGSV and AKI (<0.4 mg/l SiO₂).
    • Benefit: Avoidance of deposits and damage to expensive medical technology.

Buy silicate measuring devices for the medical sector: Testomat® 808 SIO2

Your benefits with our silicate measuring devices

  • High measuring accuracy for maximum process reliability
  • Robust technology for industrial and medical applications
  • Durable systems with simple integration
  • Technical advice and spare parts service from experts


Why silicate measurement from Heyl is the right choice for your application

The silicate measuring device Testomat® 808 SiO₂ from Heyl stands for precision, reliability and practical solutions in industrial water treatment and the medical sector. Thanks to state-of-the-art measurement technology, you receive exact limit value measurements in real time at all times - a basic requirement for safe process control.

With Heyl, you are opting for:

  • Highest measuring accuracy to prevent deposits and corrosion damage
  • Robust, durable systems, developed for demanding industrial and medical applications
  • Continuous online monitoring that detects risks early and reduces costs
  • Competent advice & support from technical experts

Whether in power plants, food production, RO/EDI systems or medical technology - Heyl offers the right solution for your requirements.

With professional silicate measurement from Heyl, you can safeguard your production processes, meet standards in the medical sector and avoid high follow-up costs due to downtime or corrosion.

Rely on Heyl silicate measurement - for maximum operational reliability, efficiency and investment protection.

Skip product gallery

Our Heyl silicate measuring devices

Testomat® 808 SIO2
Product number: 100660
Operating pressure: 1 - 4 bar | Performance/execution: 230 V/50-60 HZ
The Testomat® 808 SiO₂ from Heyl is a device developed for measuring and monitoring deionized water in medical facilities. The central importance of silicate monitoring Silicate measurement using the Testomat® 808 SiO₂ is an essential aspect of compliance with a defined limit value. Precise silicate monitoring is particularly important in process water treatment in clinics in order to prevent deposits on equipment and medical devices (MD) and to ensure the effectiveness of water treatment systems. The limit value can be set in resolution steps of 0.1 mg/l free in the working range of 0.3–1.2 mg/l. Continuous monitoring of the silicate content and compliance with the limit values allows problems to be detected at an early stage and appropriate measures to be taken to protect the equipment and treated medical devices. The Testomat® 808 SiO₂ scores with: Low reagent consumption (up to 750 analyses with one reagent set), Ease of maintenance, Very good integration into PLC/PLC through transmission of measured values and error messages using fixed mA values Performance profile: The S7 function switch can be used to set 10 limit values from 0.3 to 1.2 ppm SIO2 Analysis triggering: o Automatic interval operation (with S8, the interval pause can be set from 0 to 480 minutes) o External control (start/stop input) o Manual analysis trigger (manual start) Long operating times thanks to 500 ml indicator supply RS232 interface for optional firmware updates and data output to a computer Weekend operation monitoring through 72 hours of unattended operation (BOB) Output of status and error messages via a current interface It is an efficient and practical solution with an excellent price-performance ratio, especially for critical processes such as in the semiconductor industry and deionized water treatment in clinics, hospitals, and outpatient centers. #BBD0E0 »

€3,969.90*
Testomat® 808 SIO2 Reagent set, reagents A 100 ml & B 100 ml
Product number: 140808
100 ml-bottles of original Testomat® 808 SIO2 Reagent Set A+B for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling. Measuring range: Silica SiO2: 0.3 - 1.2 ppm  

€92.80*
Testomat® 808 SIO2 Reagent A - 500 ml
Product number: 141808
500 ml-bottle of original Testomat® 808 SIO2 Reagent A for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling.   Measuring range: Silica SiO2: 0.3 - 1.2 ppm  

€173.20*
Testomat® 808 SIO2 Reagent B - 500ml
Product number: 141809
500 ml-bottle of original Testomat® 808 SIO2 Reagent B for monitoring the level of SiO2 in the water. The bottles of original Testomat® 808 SIO2 Reagent can be used immediately in the instrument without cumbersome filling and refilling.   Measuring range: Silica SiO2: 0.3 - 1.2 ppm  

€164.00*
Annual service set professional Testomat® 808 SiO2
Product number: 890611
Contains:  2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 100 ml bottle1 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set

€176.20*
Service set Professional for 2-year maintenance Testomat® 808 SiO2
Product number: 890612
Service set contains:2 x sight glasses 30 x 33 x flat gasket 24 x 21 x insert for screw cap & suction tube 100 ml bottle1 x insert for screw cap & suction tube 500 ml bottle1 x double pump head conversion kit1 x gear motor2 x Hose connector1 x Cleaning brush set Important: After replacement, the pump must be recalibrated in Testomat® 808 SiO2.The adjustment is available from firmware version T808_83-003. Carry out a firmware update for older versions before performing the adjustment! (Serial number less than 253.061)For this calibration, it is important that you use water with a silicate content of 0 ppm, otherwise the zero point calibration will be incorrect and lead to false measurement results.To ensure this, please use the silicate filter cartridge specially developed for this process for the T808 SiO2, article 270344.(For additional information and instructions on the equipment you need for the software update, please refer to the operating instructions. The instructions "Replacing the pump head on Testomat® 808 SiO2" are also available)

€1,148.20*
Repair- and service case Testomat® 808 SiO2
Product number: 270343
Contents: 1 x 37570 Solenoid valve complete Testomat® 808 2 x 37580 Insert with screw cap and suction tube 100ml bottle 1 x 37859 double pump head Testomat® 808     1 x 31972 SUB-D null modem cable, 9-pin, 2 x socket, 3m     4 x 37579 Insert with screw cap and suction tube 500ml bottle     2 x 40050 Magnetic stirring core 4 x 37538 Tube adapter Testomat® 808     4 x 40157 Angle screw-in connector, G1/8"-6     2 x 37543 Pipe, PE, D=6 d=4 L=53mm     2 x 37544 Pipe, PE, D=6 d=4 L=140mm     6 x 40170 Viewing window 30x3     6 x 31595 Fuse solder-in, TR5, T0,1A     6 x 31592 Fuse solder-in, TR5, T1,0A     6 x 31584 Fuse, solder-in, TR5, T0.2A 6 x 31585 fuse, T0,315A     8 x 33797 O-ring 3,68 x 1,78     8 x 31666 Fuse G-, 5x20mm, T4A     8 x 33777 Flat gasket 24x2 EPDM 70     4 x 33253 Screw M3x40, A2, DIN 965     8 x 33246 pan-head screw M3x12 DIN 7985H A2     8 x 11264 O-ring 4.5 x 1.5     8 x 11245 O-ring 1,78x1,78     1 x 32286 Adapter USB > Serial -length 1.1 meter     1 x 32287 Cleaning brush set     1 x 37498 USB stick with software tool for T808 and maintenance manual     2 x 37621 Dosing needle Testomat® 808 completeTranslated with www.DeepL.com/Translator (free version)

€2,016.80*