Filter products
Testomat 2000® Antox-solution 2 x 100 ml bottle for Testomat 2000® Antox. Concentrations of oxidising agents, such as chlorine, chlorine dioxide or ozone, above TVO-approved (German drinking water ordinance) limit values have a detrimental effect on the dye contained in Testomat 2000® reagents. Exact determination of the water hardness is therefore no longer guaranteed, and the Testomat® instrument displays the error message measuring fault analysis (MST analysis). To execute the measurement correctly, a reducing agent must be added. Testomat 2000® Antox is a special version of Testomat 2000® with an additional pump for dosing a reducing agent. An oxidising agent fault is prevented prior to each analysis by adding a reducing agent to the filled measuring chamber. The further analysis of the water hardness measurement is then continued according to the standard procedure.
Cleaning reagent in 500ml-bottle for Testomat 2000® Self clean Testomat 2000® self clean is a special version of Testomat 2000® with an additional dosing pump for cleaning or disinfecting agents after an analysis. It can be used to remove possible pollution of the measuring chamber and the drain hose. After a preset number of analysis cycles, the measuring chamber is rinsed and the agent is added to the water in the measuring chamber. After a reaction time of 30 seconds, the content of the measuring chamber is dumped. The measuring chamber is subsequently rinsed twice.
500 ml bottle original Testomat® 808/BOB indicator 300 for measuring residual hardness. Limit value: 0,02°dH residual hardness 0.0356 °fH 0.356 ppm CaCO3 0.00356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB 300 indicator for measuring residual hardness. Limit value: 0,02°dH residual hardness 0.0356 °fH 0.356 ppm CaCO3 0.00356 °mmol/l
100 ml bottle original Testomat® 808/BOB indicator 300S for measuring residual hardness. Limit value: 0,05° dH residual hardness 0.089 °fH 0.89 ppm CaCO 0.0089 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB indicator 300S for measuring residual hardness. Limit value: 0,05° dH residual hardness 0.089 °fH 0.89 ppm CaCO3 0.0089 °mmol/l
Residual Hardness Measurement with Testomat 808 – Indicator Solution Type 301 for Stable Analysis Results Original liquid chemistry from Heyl for residual hardness monitoring in technical water analysis With a threshold of 0.1 °dH, this indicator solution provides a reliable and precise reading of residual hardness, ideal for processes requiring continuous water monitoring. The liquid formulation allows easy handling and a dependable chemical reaction directly in the measuring device. Heyl's original indicator solution is suitable for use with the Testomat 808 and F-BOB series. With a guaranteed minimum shelf life of 7 months after shipment from our warehouse, the solution remains accurate and ready for use throughout the entire period. Features of Indicator 302 At a defined residual hardness threshold of 0.1 °dH, the indicator solution reacts reliably, making it a stable choice for medium hardness ranges. The bottles can be used directly in the device. The indicator ensures consistent dosing and reliable results over many measurement cycles. Applications of the Indicator Solution Boiler feed water monitoring Process water Reverse osmosis systems and technical supply systems
Testomat 808 Indicator 301 – Precise Measurement Original indicator solution, reliable determination of residual hardness in water The Testomat 808 Indicator 301, 500 ml bottle from Heyl, is an original indicator for the exact measurement of residual hardness with a threshold of 0.1 °dH. Suitable for the Testomat 808 and Testomat F-BOB devices. The Indicator 301 is reliable for monitoring residual hardness. It allows safe process control with minimal maintenance effort. Highly Precise Residual Hardness Determination The Testomat 808 Indicator 301 from Heyl is a specially developed original indicator for highly precise determination of residual hardness in water treatment systems. It is precisely calibrated to the measurement methodology of the Testomat 808 and Testomat F-BOB and ensures reliable detection of residual hardness up to a threshold of 0.1 °dH. Using the original Heyl indicator guarantees consistent measurement quality, as reaction behavior, color change, and stability are optimized for the device parameters. Only by using the original Testomat 808 Indicator can proper device functionality be ensured and the corresponding device warranty maintained.
100 ml bottle original Testomat® 808/BOB indicator 302 for measuring residual hardness. Limit value: 0,2° dH residual hardness 0.356 °fH 3.56 ppm CaCO3 0.0356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
Testomat® 808 Indicator 302 500 ml Residual hardness threshold: 0.2 °dH for Testomat® 808 The Testomat 808 Indicator 302, 500 ml bottle, is designed for threshold monitoring of residual hardness at 0.2 °dH in water samples through color change. Indicator 302 enables precise measurement of residual hardness. It is optimized for the Testomat 808 and F-BOB to detect limescale deposits early. Precise Residual Hardness Monitoring at 0.2 °dH The Testomat® 808 Indicator 302 is a specially calibrated original indicator for reliable threshold monitoring of residual hardness in water samples at 0.2 °dH. The indicator solution is specifically designed for use with the Testomat® 808 and Testomat® F-BOB, enabling precise water hardness measurement through a clearly defined color change. Even the smallest deviations can be detected early, effectively preventing limescale deposits in downstream systems. Manufacturer Warranty and Original Indicators Full operational reliability and warranty claims for Testomat® devices can only be guaranteed when using original indicators. Using the original Indicator 302 ensures that measurement accuracy, device protection, and long-term reliability meet the manufacturer’s specifications.
Testomat 808 Indicator 303 – Precise Residual Hardness Measurement Original indicator solution for determining residual hardness The Testomat 808 Indicator 303, 500 ml bottle from Heyl, is an original indicator solution for measuring residual hardness through color change with the Testomat 808 and Testomat F-BOB. It provides clear results at a threshold of 0.1 °dH. Indicator 303 is designed for residual hardness monitoring. With minimal maintenance, it enables safe process control. Highly Precise Residual Hardness Monitoring The Testomat 808 Indicator 303 from Heyl is a specially developed original indicator solution for precise measurement of residual hardness in water samples through a clearly defined color change. It is optimally calibrated for use with the Testomat 808 and Testomat F-BOB and delivers reliable measurement results at a threshold of 0.1 °dH. Thanks to its exact adaptation to the measurement methodology of the devices, it ensures high measurement accuracy and reproducibility. Deviations can be detected early, effectively preventing limescale formation. Manufacturer Warranty and Original Indicators The manufacturer’s warranty for Testomat® devices can only be guaranteed when using Heyl original indicators.
100 ml bottle original Testomat® 808/BOB indicator for measuring residual hardness. Limit value: 0,3° dH residual hardness 0.534 °fH 5.34 ppm CaCO3 0.0534 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
100 ml bottle original Testomat® 808/BOB indicator 305 for measuring residual hardness. Limit value: 0,5° dH residual hardness 0.89 °fH 8.9 ppm CaCO3 0.089 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
The Testomat 808 Indicator 305, 500 ml bottle, is an original indicator solution for measuring residual hardness with a threshold of 0.5 °dH. The indicator is specially designed for Testomat 808 and Testomat F-BOB devices, providing precise and reliable measurement results. Benefits of the Original Testomat 808 Indicator 305 from Heyl The Testomat 808 Indicator 305 is optimally matched to the requirements of Testomat 808 and Testomat F-BOB devices and ensures reliable results during continuous operation. Your Advantages When Using Original Heyl Indicators at a Glance Maximum Measurement Accuracy: Precisely defined composition for reproducible and accurate residual hardness measurements. Perfect Device Compatibility: 100 % matched to Testomat 808 and Testomat F-BOB – no calibration issues or incorrect measurements. Reliable Process Monitoring: Ideal for continuous monitoring of residual hardness. System Protection: Early and reliable detection of limit value exceedances protects downstream processes and components. Warranty and Safety Through Original Heyl Quality Using the original Testomat 808 Indicator 305 ensures that the manufacturer-specified measurement accuracy, functional safety, and device lifespan are fully maintained. Using original indicators is a prerequisite for: proper operation of Testomat measuring devices maintaining warranty and guarantee claims compliant and reliable process control With the original indicator, you invest in measurement reliability, process stability, and long-term operational safety – without compromise.
Original Testomat 808 Indicator 310 from Heyl for Residual Hardness Monitoring Residual hardness threshold: 1 °dH for Testomat 808 and F-BOB The Testomat 808 Indicator 310, 500 ml bottle, measures the residual hardness in water as a threshold monitor with color change for the Testomat 808 and F-BOB. The threshold is set at 1 °dH. The Indicator 310 enables reliable threshold measurement of residual hardness through a color reaction. Benefits of the Original Testomat 808 Indicator 310 The Testomat 808 Indicator 310 is the original indicator solution from Heyl for monitoring residual hardness in water with a threshold of 1 °dH. Its clearly defined color change ensures safe and easily readable measurement results on the Testomat 808 and F-BOB devices. Your Advantages When Using Heyl Original Indicators for Testomat 808 at a Glance Reliable Threshold Measurement: Clear indication via green or red signal for safe detection of residual hardness exceeding 1 °dH. Optimized for the Measuring Device: Specifically designed for Testomat 808 and Testomat F-BOB – ensures trouble-free operation and precise results. High Process Reliability: Ideal for continuous monitoring of residual hardness in water-carrying processes. Consistent Indicator Quality: Ensures reproducible results throughout the entire usage period. Warranty and Operational Safety with Original Indicator 310 for Testomat 808 from Heyl Using the original Testomat 808 Indicator 310 is crucial for reliable measurement function and proper operation of the Testomat devices. Using original indicators ensures: compliance with manufacturer specifications full measurement accuracy and operational reliability retention of warranty and guarantee claims long-term protection for downstream systems With the original Testomat 808 Indicator 310, you rely on dependable threshold monitoring, stable processes, and maximum operational safety.
100 ml bottle original Testomat® 808/BOB indicator 310 for measuring residual hardness. Limit value: 1°dH residual hardness 1.78 °fH 17.8 ppm CaCO3 0.178 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
100 ml bottle original Testomat® 808/BOB indicator 320 for measuring residual hardness. Limit value: 2° dH residual hardness 3.56 °fH 35.6 ppm CaCO3 0.356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB indicator 320 for measuring residual hardness. Limit value: 2°dH residual hardness 3.56 °fH 35.6 ppm CaCO3 0.356 °mmol/l
Heyl Testomat 808 Original Indicator 330 Residual hardness threshold measurement with the Testomat 808 The Testomat 808 Indicator 330, 500 ml bottle, is used for measuring residual hardness. Indicator 330 monitors residual hardness at a value of 1.5 °dH and is suitable for use with the Testomat 808 and F-BOB devices. Testomat 808 Indicator 330 – Reliable Residual Hardness Monitoring at 1.5 °dH The Testomat 808 Indicator 330 was specifically developed for monitoring residual hardness in water treatment. With a defined threshold of 1.5 °dH, this indicator solution is ideal for applications with the corresponding water hardness. It is fully compatible with Testomat 808 and Testomat F-BOB devices and ensures stable, continuous measurement in your water treatment processes. The original indicator from Heyl provides a clear and reliable color change, allowing for a quick assessment of water quality. Using the original indicator solution ensures high process reliability and supports uninterrupted operation of your systems. Heyl Original Indicator – Your Safety for Measurement, Device, and Warranty Using the original Testomat 808 Indicator 330 is an essential part of reliable residual hardness monitoring. Only original indicator solutions ensure that the manufacturer’s specified measurement accuracy and functional parameters are consistently maintained. At the same time, using the original indicator ensures: the retention of warranty and guarantee claims proper operation of the measuring devices precise measurement results and long-term investment and operational security
100 ml bottle original Testomat® 808/BOB indicator 330 for measuring residual hardness. Limit value: 3° dH residual hardness 5.34 °fH 53.4 ppm CaCO3 0.534 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB indicator 350 for measuring residual hardness. Limit value: 5°dH residual hardness 8.93 °fH 89.3 ppm CaCO3 0.893 °mmol/l
500 ml-bottle original Testomat® Indicator TC 2100 for limit value 1,00-20,00°dH for measuring carbonate hardness in water. °dH (resolution): 1,00-20,00 (1,00) °f (resolution): 1,79-35,8 (1,79) ppm CaCO3 (resolution):18-358 (18) mmol/l (resolution): 0,36-7,14 (0,36)
Testomat Indicator TC2050 500 ml Carbonate Hardness Measurement for Testomats The Testomat Indicator TC2050, 500 ml bottle, measures carbonate hardness in water. Carbonate hardness (also called temporary hardness) describes the amount of dissolved calcium and magnesium carbonates in water. It is a critical parameter in industrial water treatment, as it significantly affects the water's buffering capacity. Excessive carbonate hardness can lead to scale formation, deposits in pipelines, and efficiency losses in heat exchangers. At the same time, carbonate hardness is an important control parameter for softening and dosing processes. The Testomat Indicator TC2050 allows reliable, automatic monitoring of carbonate hardness through a precise color reaction. It is especially suitable for process and utility water with a pH value > 4 and supports stable and safe process control. What values can be measured? 0.50–5.00 °dH, resolution 0.50 0.90–8.96 °f, resolution 0.90 8.9–89.5 ppm CaCO₃, resolution 8.9 0.18–1.79 mmoI/I, resolution 0.18 Where can the indicator be used? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO®-C
Testomat® Indicator TH2005 from Heyl – Precise Low-Range Residual Hardness Measurement 2x100 ml Residual hardness 0.05–0.50 °dH for Testomat 2000 2x100 ml Testomat Indicator TH2005, 2x100 ml bottles, for measuring residual hardness. The original bottles allow direct use without transferring the solution. The Testomat® Indicator TH2005 is an original indicator solution for reliable measurement and threshold monitoring of residual hardness in the range of 0.05 to 0.50 °dH. Supplied in two practical 100-ml original bottles, the indicator enables direct application without transferring. The indicator is particularly suitable for applications with high water quality requirements, where precise monitoring of low hardness ranges is essential. Which devices is the TH2005 indicator from Heyl compatible with? The TH2005 indicator is compatible with the following measuring devices: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat® Limit Which values does the original TH2005 indicator from Heyl measure? The Testomat® Indicator TH2005 covers multiple units and offers high resolution: 0.05–0.50 °dH (Resolution 0.01) 0.09–0.89 °f (Resolution 0.02) 0.89–8.93 ppm CaCO₃ (Resolution 0.2) 0.01–0.09 mmol/l (Resolution 0.01) Using the original indicator ensures high measurement accuracy, proper device operation, and retention of warranty and guarantee claims.