Water Analyzers
- Devices
-
Parameters
- Water hardness (Ca2+ and Mg2+)
- Total hardness (TH)
- Carbonate hardness (KH)
- Acid capacity (pH 4.3, KS 4.3) and p-value (pH 8.2, KS 8.2)
- Base capacity (KB82)
- Bromine (Br)
- Free Chlorine (HOCl)
- Total chlorine (CC)
- Chlorine dioxide (ClO2)
- Chromate & Chromium Cr(VI)
- Iron (II + III dissolved - Fe3O4)
-
Silicate (SiO2 - dissolved)
- Ortho-Phosphat (P2O5)
- Polymere & Polyacrylate
- Monochloramine (NH2CL)
- TESTOMAT® - Accessories
- Spare Parts
- Service sets and maintenance cases
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
- OFFERS
Filter products
–
Testomat® 808 SIO2
Product number:
100660
Operating pressure:
1 - 4 bar
|
Performance/execution:
230 V/50-60 HZ
The Testomat® 808 SiO₂ from Heyl is a device developed for measuring and monitoring deionized water in medical facilities.
The central importance of silicate monitoring
Silicate measurement using the Testomat® 808 SiO₂ is an essential aspect of compliance with a defined limit value. Precise silicate monitoring is particularly important in process water treatment in clinics in order to prevent deposits on equipment and medical devices (MD) and to ensure the effectiveness of water treatment systems. The limit value can be set in resolution steps of 0.1 mg/l free in the working range of 0.3–1.2 mg/l. Continuous monitoring of the silicate content and compliance with the limit values allows problems to be detected at an early stage and appropriate measures to be taken to protect the equipment and treated medical devices.
The Testomat® 808 SiO₂ scores with:
Low reagent consumption (up to 750 analyses with one reagent set),
Ease of maintenance,
Very good integration into PLC/PLC through transmission of measured values and error messages using fixed mA values
Performance profile:
The S7 function switch can be used to set 10 limit values from 0.3 to 1.2 ppm SIO2
Analysis triggering:
o Automatic interval operation (with S8, the interval pause can be set from 0 to 480 minutes)
o External control (start/stop input)
o Manual analysis trigger (manual start)
Long operating times thanks to 500 ml indicator supply
RS232 interface for optional firmware updates and data output to a computer
Weekend operation monitoring through 72 hours of unattended operation (BOB)
Output of status and error messages via a current interface
It is an efficient and practical solution with an excellent price-performance ratio, especially for critical processes such as in the semiconductor industry and deionized water treatment in clinics, hospitals, and outpatient centers.