Filter products
The bottles of original Testomat 2000® Chlorine Reagent Set T can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content: 2 x 500 ml A, 1 x 400 ml B, 1 x 200 ml C Measuring ranges: Total chlorine: 0,00-0,99 mg/l (Resolution: 0,01 mg/l) 1,0-0-2,5 mg/l (Resolution: 0,1 mg/l)
The bottles of Testomat 2000® Chlorine Reagent Set T 50 % can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content: 1 x 500 ml CL2250A 1 x 200 ml CL2250B 1 x 100 ml CL2250C Measuring ranges: Total chlorine: 0.00 - 0.99 mg/l (Resolution: 0.01 mg/l) 1 - 2.5 mg/l (Resolution: 0.1 mg/l) Free chlorine: 0.00 - 0.99 mg/l (Resolution: 0.01 mg/l) 1 - 2.5 mg/l (Resolution: 0.1 mg/l)
The 500 ml-bottles of original Testomat 2000® Reagenz CIO2 A/B bottles can be used immediately in the Testomat 2000®® CIO2 without cumbersome filling and refilling. Measuring range: chlorine dioxide (ClO2): 0.00 - 4.70 mg/l
The 500 ml-bottles of original Testomat 2000® Reagenz CL 2250 C can be used immediately in the instrument without cumbersome filling and refilling. Measuring ranges: Total chlorine: 0,00-0,99 mg/l (Resolution: 0,01 mg/l) 1,0-0-2,5 mg/l (Resolution: 0,1 mg/l)
Testomat 2000 Reagent CL 2250 A 500 ml Chlorine Reagent CL 2250 A for Reliable Measurement of Free and Total Chlorine for Safe Water Treatment and System Protection The Testomat 2000 Reagent CL 2250 A, 500 ml bottle, is used for measuring total chlorine and free chlorine in water samples. The measuring range is 0.00–0.99 mg/l (resolution 0.01 mg/l) and 1.0–2.5 mg/l (resolution 0.1 mg/l). The CL 2250 A reagent can be used directly in Testomat 2000 CLF or CLT devices without transferring and is ideal for membrane protection in reverse osmosis systems. Where can the CL 2250 reagent be used to monitor chlorine? It can be used in: Testomat 2000® THCL® Testomat 2000® CLF Testomat 2000® CLT Testomat 2000® CLT self clean Why is measuring free and total chlorine so important? Measuring free and total chlorine is a central part of professional water monitoring. Free chlorine (e.g., hypochlorous acid and hypochlorite) is the disinfecting form and crucial for the microbiological safety of water. Total chlorine also includes combined chlorine (chloramines), which has disinfecting properties but is significantly less effective and can lead to odor and corrosion problems. Monitoring free and total chlorine is essential to ensure water quality, the effectiveness of disinfection, and to detect possible over-concentration in process water. In sensitive applications such as reverse osmosis systems, precise chlorine monitoring is particularly important because free chlorine can damage or destroy membranes. The CL 2250 A reagent supports safe process control, protects system components, and helps reliably maintain standard and limit values.
Testomat 2000® reagent FE 2005 A in 500 ml bottleMeasuring range: 0 - 1.0 [mg/l]Test substance: dissolved iron (II) and (III) For the analyser T2000® Fe, whose measuring ranges are as follows:Range I: 0 - 0.65 mg/l, resolution: 0.01 mg/l Range II: 0.7 - 1.0 mg/l, resolution 0.1 mg/l The 500 ml bottles of the original Testomat® reagent can be inserted directly into the instrument without any cumbersome decanting.
Content: 0.5 Liter (€629.20 / 1 Liter)
Testomat 2000® reagent FE 2005 B in 500 ml bottleMeasuring range: 0 - 1.0 [mg/l]Test substance: dissolved iron (II) and (III) For the analyser T2000® Fe, whose measuring ranges are as follows: Range I: 0 - 0.65 mg/l, resolution: 0.01 mg/l Range II: 0.7 - 1.0 mg/l, resolution 0.1 mg/l The 500 ml bottles of the original Testomat® reagent can be inserted directly into the instrument without any cumbersome decanting.
Content: 0.5 Liter (€683.40 / 1 Liter)
Bulk container - 20 litre canisterTo use the canister, the suction lance (art. no.: 40535) is required.
Bulk container - 5L canisterTo use the canister, the suction lance (art. no.: 40536) is required.
Testomat 2000 Reagent CL 2250 B 500 ml Second reagent for chlorine measurement with the Testomat 2000 Chlorine system Precise chlorine analysis with Testomat 2000 Reagent CL 2250 B The Testomat 2000 Reagent CL 2250 B is specifically designed for reliable determination of free and total chlorine in water. As a second reagent, it complements Reagent A and allows accurate measurement without additional transfer steps. Thanks to its fine resolution, the reagent is ideal for applications requiring precise and continuous chlorine monitoring. Measurement range and advantages of Reagent CL 2250 B The measurement range of the reagent is 0.00–0.99 mg/L with a resolution of 0.01 mg/L, and 1.0–2.5 mg/L with a resolution of 0.1 mg/L. This allows both very low and higher chlorine concentrations to be accurately detected. In combination with Reagent A, CL 2250 B ensures reliable, reproducible, and low-maintenance chlorine determination. Where can the reagent be used? Reagent CL 2250 B is suitable for use in various Testomat 2000 series devices and supports flexible applications in different measurement environments. Compatible Testomat 2000 devices The reagent can be used in the following devices: Testomat 2000® THCL® Testomat 2000® CLF or CLT Testomat 2000® CLT self clean
Cleaning reagent in 500ml-bottle for Testomat 2000® Self clean Testomat 2000® self clean is a special version of Testomat 2000® with an additional dosing pump for cleaning or disinfecting agents after an analysis. It can be used to remove possible pollution of the measuring chamber and the drain hose. After a preset number of analysis cycles, the measuring chamber is rinsed and the agent is added to the water in the measuring chamber. After a reaction time of 30 seconds, the content of the measuring chamber is dumped. The measuring chamber is subsequently rinsed twice.
The 500 ml-bottles of original Testomat 2000® Reagenz SO3 A can be used immediately in the Testomat 2000®® SO3 without cumbersome filling and refilling. Measuring range: Sulphite SO3: 0.0 - 20.0 mg/l
The 500 ml-bottles of original Testomat 2000® Reagent SO3 B can be used immediately in the Testomat 2000®® SO3 without cumbersome filling and refilling. Measuring range: Sulphite SO3: 0.0 - 20.0 mg/l
The 500 ml-bottles original Testomat 2000® Reagenz CrVI 2100 A can be used immediately in the instrument without cumbersome filling and refilling. Measuring ranges: Chromate: 0 - 1.0 mg/l (Resolution: 0.01 mg/l) 1 - 2 .0 mg/l (Resolution: 0.1 mg/l) Chrome-VI: 0 - 1.0 mg/l (Resolution: 0.01 mg/l)
The 500 ml-bottles original Testomat 2000® Reagenz CrVI 2100 B can be used immediately in the Testomat 2000® CrVI without cumbersome filling and refilling. Measuring ranges: Chromate: 0 - 1.0 mg/l (Resolution: 0.01 mg/l) 1 - 2 .0 mg/l (Resolution: 0.1 mg/l) Chrome-VI: 0 - 1.0 mg/l (Resolution: 0.01 mg/l)
Testomat Chlorine Reagent Kit M (Monochloramine) for the Testomat LAB Monochloramine (NH2CL). (Item no.: 116109)
500 ml bottle original Testomat® 808/BOB indicator 300 for measuring residual hardness. Limit value: 0,02°dH residual hardness 0.0356 °fH 0.356 ppm CaCO3 0.00356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB 300 indicator for measuring residual hardness. Limit value: 0,02°dH residual hardness 0.0356 °fH 0.356 ppm CaCO3 0.00356 °mmol/l
100 ml bottle original Testomat® 808/BOB indicator 300S for measuring residual hardness. Limit value: 0,05° dH residual hardness 0.089 °fH 0.89 ppm CaCO 0.0089 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.
500 ml bottle original Testomat® 808/BOB indicator 300S for measuring residual hardness. Limit value: 0,05° dH residual hardness 0.089 °fH 0.89 ppm CaCO3 0.0089 °mmol/l
Residual Hardness Measurement with Testomat 808 – Indicator Solution Type 301 for Stable Analysis Results Original liquid chemistry from Heyl for residual hardness monitoring in technical water analysis With a threshold of 0.1 °dH, this indicator solution provides a reliable and precise reading of residual hardness, ideal for processes requiring continuous water monitoring. The liquid formulation allows easy handling and a dependable chemical reaction directly in the measuring device. Heyl's original indicator solution is suitable for use with the Testomat 808 and F-BOB series. With a guaranteed minimum shelf life of 7 months after shipment from our warehouse, the solution remains accurate and ready for use throughout the entire period. Features of Indicator 302 At a defined residual hardness threshold of 0.1 °dH, the indicator solution reacts reliably, making it a stable choice for medium hardness ranges. The bottles can be used directly in the device. The indicator ensures consistent dosing and reliable results over many measurement cycles. Applications of the Indicator Solution Boiler feed water monitoring Process water Reverse osmosis systems and technical supply systems
Testomat 808 Indicator 301 – Precise Measurement Original indicator solution, reliable determination of residual hardness in water The Testomat 808 Indicator 301, 500 ml bottle from Heyl, is an original indicator for the exact measurement of residual hardness with a threshold of 0.1 °dH. Suitable for the Testomat 808 and Testomat F-BOB devices. The Indicator 301 is reliable for monitoring residual hardness. It allows safe process control with minimal maintenance effort. Highly Precise Residual Hardness Determination The Testomat 808 Indicator 301 from Heyl is a specially developed original indicator for highly precise determination of residual hardness in water treatment systems. It is precisely calibrated to the measurement methodology of the Testomat 808 and Testomat F-BOB and ensures reliable detection of residual hardness up to a threshold of 0.1 °dH. Using the original Heyl indicator guarantees consistent measurement quality, as reaction behavior, color change, and stability are optimized for the device parameters. Only by using the original Testomat 808 Indicator can proper device functionality be ensured and the corresponding device warranty maintained.
100 ml bottle original Testomat® 808/BOB indicator 302 for measuring residual hardness. Limit value: 0,2° dH residual hardness 0.356 °fH 3.56 ppm CaCO3 0.0356 °mmol/l Please notice, that 100 ml. bottles are only available in packages of 2 or 3 pieces.