9 pole, 2 x bush, 3m • associated USB adapter #850929
for bulk container reagent A PO4 (20 liter container)
for large containers of reagent B PO4 (5 liter containers)
Support sleeve as a spare part for the Testomat LIMIT
The replacement sensor is suitable for the NEOMERIS Softmaster RS. Manufacturer's designation: electrical measuring cell for SE and DSE (2828)
Switching power supply Testomat EVO – 100–240 V / 100–350 VDC Reliable power supply for Testomat EVO devices The Testomat EVO switching power supply is the central component for a stable and efficient power supply in Testomat EVO TH and TH CAL devices. It reliably converts the primary input voltage of 100–240 V AC or 100–350 V DC (47–63 Hz) into the required secondary voltages of 3.3 V / 12 V / 24 V. It thus provides a reliable power supply for all electronic components in the device. Why buy a switching power supply for Testomat EVO online? Immediately compatible with current Testomat EVO models Stable power supply for Testomat EVO devices Optimised for long-term reliability and durability Quick replacement for defective power supply boards This power supply provides the necessary operational reliability to consistently supply the measuring chamber, controller, solenoid valves, display and other assemblies for many years – a crucial factor for users who depend on continuously accurate measurements. Important note on compatibility For Testomat EVO TH and TH CAL devices up to serial number 258464, defective 230 V power supplies (formerly item no. 32390) can no longer be replaced on a one-to-one basis. The new switching power supply (32394) cannot be used in the old motherboard! For correct operation, the T EVO_GP motherboard (item no. 32383) must also be replaced in these cases. Motherboard T EVO_GP complete – Item no. 32383 The central collection board for all assemblies of your Testomat EVO The T EVO_GP circuit board provides internal power and signal distribution for the entire device. As a “collector board”, it connects essential components and ensures their reliable power supply: e.g. measuring chamber holder, DosiClip, power supply unit, controller, solenoid valve, display, etc. It thus forms the functional heart of every Testomat EVO device and is indispensable for stable operation. Who is the Testomat EVO switching power supply ideal for? This spare parts kit is intended for: Service technicians who need to repair defective equipment Water treatment plants that want to minimise downtime Industrial customers who want to ensure long-term equipment availability Order online now – fast delivery and reliable quality from Heyl You can easily and conveniently purchase the 32394 switching power supply and, if necessary, the 32383 motherboard for the Testomat EVO device type from our online shop. Benefit from tested quality, expert spare parts supply and short delivery times. Get a 3% discount on all Heyl items in our online shop.
T EVO_GP circuit board, complete – buy online Central motherboard for Testomat EVO devices – reliable control and power distribution The T EVO_GP circuit board, complete (item no. 32383), is the central motherboard of the Testomat EVO device and forms the heart of the entire internal electronics. As a so-called collector board, it handles all power and signal distribution and ensures that all assemblies in the device work together reliably. If you need to replace a defective motherboard or want to restore your device to full functionality, this item is the right original spare part, which you can conveniently purchase online from HeylNeomeris. Function & tasks of the motherboard for the Testomat EVO The T EVO_GP circuit board ensures the central electrical supply and communication for all essential components, including: Measuring chamber holder DosiClip Power supply Controller Solenoid valve Display Other internal assemblies The motherboard is therefore responsible for the basic supply of the individual assemblies. Why order this motherboard online? Original spare part from Heyl for maximum compatibility and operational reliability Quick replacement in case of defects Stable operation of all internal assemblies Ensures precise measurement processes and reliable control functions Ideal for maintenance, repair and preventive replacement The high-quality workmanship and coordinated design ensure long-term, reliable device functionality – a decisive advantage for users who require maximum measurement accuracy and process reliability. Buy online now – fast delivery & certified brand quality Order the T EVO_GP circuit board, complete (item no. 32383) directly from our online shop and benefit from fast availability, secure spare parts supply and reliable product quality. Get a 3 % online shop discount on all Heyl items. Buy the circuit board now to restore your Testomat® EVO device to full functionality – reliable, efficient and ready for immediate use. Do you have any questions about the product? We are also happy to answer your questions by telephone.
230 V Process Water Analyzer for the Chinese Market – Testomat 2000 CN Reliable Water Quality Monitoring with Integrated SD Logger The Testomat 2000 CN with SD card data logger and 230 V power supply is a water analysis device for continuous monitoring of water quality. It measures key parameters such as water hardness, carbonate hardness, p-value, and minus m-value. With its Chinese-language menu, the device is specifically designed for use in the Chinese market. The integrated SD card stores measurement data and error messages directly. The standard TH2005 reagents comply with local market requirements for soft water. Integrated relays allow cooperation with external titration valves, while SD card data storage ensures clear documentation and convenient evaluation of measurement results. Market-specific reagents and a robust technical design ensure high reliability during continuous operation. Where can the Testomat 2000 CN be used? The Testomat 2000 CN is suitable for monitoring water quality in various applications: Boiler water Softened water Condensate circuit water Pharmaceutical water Tap water Groundwater The Chinese-language menu makes this device specifically suitable for use in Chinese-speaking regions. Features and Capabilities of the Testomat 2000 CN The device continuously monitors relevant water parameters and delivers real-time measurement results. The 230 V power supply allows easy integration into existing systems. Additionally, relay outputs and optional interfaces enable flexible connection to higher-level control and monitoring systems.
Online Monitoring of Total Chlorine and Water Hardness with the T 2000 THCL Testomat 2000 THCL – Online analyzer by Heyl with photometric chlorine measurement and automatic titration The Testomat 2000 THCL is part of the T 2000 device family from Heyl, designed for simultaneous online monitoring of total chlorine content and water hardness. Using the photometric DPD method, it reliably measures total chlorine in the range of 0–2.5 mg/l (ppm), while fully automatic titration determines water hardness from 0.25 to 2.50 °dH. The device combines photometric total chlorine measurement with fully automatic water hardness titration in a 230 V system. Integrated limit relays allow direct implementation of alarm and control functions, while optional interfaces enable extended external data recording via SD card data loggers or analog current interfaces (e.g., 0/4–20 mA). Features of the Testomat 2000 THCL It measures total chlorine using the proven DPD method and simultaneously determines water hardness via automatic titration. Two independently programmable limit contacts allow direct monitoring and control of external processes, while an optional interface card stores data for long-term documentation or process monitoring. Applications of the Testomat 2000 THCL Monitoring of reverse osmosis systems Protection of reverse osmosis membranes from scaling due to hardness and damage from excessive chlorine Monitoring of softening and chlorination units in drinking water systems Performance Profile of the Testomat 2000 THCL Two independently programmable limit contacts for monitoring and control; analysis results can be recorded via optional interface card (current interface SK910) for a point or strip chart recorder (0/4–20 mA) or SD-Card data logger Testomat 2000® Menu-guided operation and programming via plain text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 failed analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests
Testomat 2000 – Online Analysis Device for Water Hardness and Other Parameters Continuous water quality monitoring with automatic titration and flexible parameter selection The Testomat 2000 is a versatile analysis device for the continuous determination of key water quality parameters such as water hardness, carbonate hardness, p-value, and minus m-value. The process photometer operates fully automatically with a precise piston dosing pump and plain-text menu display, allowing measurement, analysis, and control without manual intervention. Individually selectable indicators enable different parameters and measurement ranges, while internal limit contacts ensure reliable monitoring and alarm functions. Depending on the selected indicator, the device measures residual hardness, total hardness, carbonate hardness, p-value, or minus m-value fully automatically via precise titration. Two independently programmable limit contacts support automatic control and alarm functions, while external control options such as range-dependent measurement triggering or versions with SD card data logger are available for documentation and process analysis. What functions does the Testomat 2000 from Heyl offer? It combines modern measurement principles with practical control and evaluation functions. By selecting different indicator types, it can be used in a wide variety of applications. Two freely programmable limit values with adjustable hysteresis support monitoring tasks, and optional interfaces expand the device for complete data recording or integration with control systems. Applications for the Testomat 2000 Hardness Monitoring water quality in water treatment, blending, and drinking water systems Monitoring and quality control of softening systems with or without blending Monitoring and quality assurance of decarbonization systems Prevention of acid intrusion in decarbonization systems Boiler monitoring of steam boilers Performance Profile of the Testomat 2000 Simple, menu-guided operation and programming via plain-text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, or p-value selectable via indicator choice Free choice of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator volumes: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests
Testomat 2000 Antox for Online Water Analysis with Reductant Dosing Precise Water Hardness and Parameter Monitoring The Testomat 2000 Antox is a specialized version of the Testomat 2000 with an additional pump for dosing a reductant. It was specifically designed to eliminate measurement interference caused by oxidizing substances. The additional pump doses the reductant directly into the measurement chamber before the analysis begins, ensuring that the subsequent measurement is conducted under stable conditions. The precise piston dosing pump guarantees high measurement accuracy. The extra reductant dosing pump removes measurement errors caused by oxidizing substances in the sample water chamber. The water analysis is then automatically carried out using the standard procedure, allowing reliable measurement of residual hardness, total hardness, carbonate hardness, p-value, and minus m-value. Adjustable analysis triggering in interval or dynamic mode, external control options, and freely programmable limit contacts ensure flexible integration. What functions does the Testomat 2000 Antox offer? The selection of different indicators allows measurement of various parameters, and the precise piston dosing pump ensures reproducible results. Analysis can be triggered automatically in timed intervals or dynamically. External water meter signals can be used for analysis triggering. Additionally, there are two independently programmable limit contacts for automatic control and alarm functions. Where can the Testomat 2000 Antox be used? Oxidizing agents – especially chlorine – are present in water in many technical, municipal, and industrial applications. Other application areas include: Cooling water circuits Process water treatment Food and beverage industry Chemical industry Performance profile of the Testomat 2000 Antox Easy menu-guided operation and programming via plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator Choice of hardness units in °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaust-dependent interval operation) Flow-dependent via water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for service request
Online Bromine Analyzer for Process Monitoring Continuous Br2 analysis with automatic reagent dosing and limit monitoring The Testomat 2000 Br2 is an online analysis device for continuous monitoring of bromine (Br2) levels. After a short reaction time of approximately one minute, it delivers precise results in the range of 0–5.6 mg/L (ppm). The device features two independently programmable limit contacts for monitoring and controlling external processes. Analyses can be triggered automatically at intervals or via external signals, while internal error documentation and a programmable maintenance interval ensure reliability. The Testomat 2000 Br2 is suitable for monitoring disinfectant dosing and quality assurance of water in technical systems. After automatic addition of reagents, the measurement result is displayed on a plain-text screen, and two limit contacts can be used for switching or alarm functions. External controls or water meter signals can influence the analysis triggering. Functions of the Testomat Two independently programmable limit contacts allow monitoring of critical bromine concentrations and integration into automated control processes. Additionally, the device can monitor two measurement points using external solenoid valves. Typical Applications Swimming pools and indoor pools Process water in industry Water treatment plants Food and beverage industry Why is bromine measurement important? Bromine is used as a disinfectant and is only effective within a narrow concentration range. Too low bromine levels lead to insufficient disinfection, while too high levels can cause material damage, irritation, and unnecessary chemical consumption. Continuous bromine monitoring ensures safe dosing, protects equipment, and guarantees consistent water quality in swimming pools, process water, and industrial water applications. Performance Profile of the Testomat 2000 Br2 Analysis via automatic dosing of 2 reagents Measurement result display after approx. 1 minute reaction time 2 independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CAL – Analysis Device with Calibration Function Reliable measurement of key water parameters with a water analysis device from Heyl The Testomat 2000 CAL is an online analysis device for the continuous monitoring of important water parameters such as total hardness, carbonate hardness, p-value, and minus m-value. With its integrated calibration function, the device ensures consistently precise measurement results. Freely definable limit values, switching outputs, and diagnostic functions support reliable process monitoring. Measurements can be triggered based on time or quantity, allowing the Testomat 2000 CAL to adapt flexibly to different plant concepts. Technical Features of the Testomat 2000 CAL The integrated calibration function increases measurement reliability and reduces manual intervention. Freely programmable switching outputs can reliably trigger warnings, dosing processes, or external control systems. The piston dosing pump ensures precise reagent dosing and consistent measurement results while requiring minimal maintenance. Where can the Testomat be used? Monitoring water quality in water treatment, blending, and drinking water systems Monitoring and quality assurance of softening systems with or without blending Monitoring and quality assurance of decarbonization systems Prevention of acid intrusion in decarbonization and desalination systems Performance Profile of the Testomat 2000 CAL Simple, menu-guided operation and programming via plain-text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator choice Free selection of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy due to precise piston dosing pump Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator volumes: 100 ml and 500 ml bottles Programmable maintenance interval for maintenance requests
Testomat 2000 CLF – Process Photometer for Free Chlorine Analysis Precise determination of free chlorine in water with the Testomat 2000 by Heyl The Testomat 2000 CLF is an automatic online process photometer for continuous monitoring of free chlorine content in water within a measuring range of 0–2.5 mg/l (ppm). In a wet-chemical measurement process, two reagents are automatically dosed, enabling photometric measurement of the chlorine value within a short reaction time. Two independently programmable limit contacts with adjustable hysteresis provide additional monitoring and control functions directly within the process. In addition to automatic interval measurements, external analysis triggering and quantity-dependent measurements via a contact water meter can be implemented. Technical Features of the Testomat 2000 for Free Chlorine Measurement The Testomat 2000 CLF features internal error documentation, optional interfaces for measurement value output (e.g. 4–20 mA or SD card data logger), and a programmable maintenance interval. By switching external solenoid valves, two measuring points can be monitored. Where can the Testomat be used? Monitoring of chlorination systems in drinking water or swimming pool applications Protection of reverse osmosis membranes Monitoring of chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLF Analysis using automatic dosing of two reagents Display of the analysis result after a reaction time of approximately 1 minute Two independently programmable limit contacts for monitoring and control tasks; recording of analysis results with optional plug-in card (current interface SK910) for point or line recorders (0/4–20 mA) or an SD card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) Adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CIO2 – Online Photometer for Chlorine Dioxide Monitoring Precise CIO2 measurement for water quality and process safety with Heyl technology The Testomat 2000 CIO2 is an online photometer for continuous monitoring of chlorine dioxide (CIO2) levels in water. It delivers reliable measurements up to approx. 4.7 mg/L within just a few minutes of reaction time. In a photometric process, two reagents are automatically dosed, and a precise concentration measurement is performed in a short reaction time. Results are available after approximately one minute. Two independently programmable limit contacts with adjustable hysteresis enable direct process monitoring and control, for example to trigger alarms or switch external devices. The piston dosing pump and internal diagnostic functions ensure high measurement accuracy. Technical Features of the Testomat 2000 CIO2 With a plain-text menu interface, programmable measurement intervals, and multiple freely adjustable limit contacts, the device provides a precise, stable, and versatile solution for continuous CIO2 (chlorine dioxide) monitoring. Additional functions such as external analysis triggering, quantity-dependent measurement, and internal diagnostics extend usability for complex process environments. Applications Drinking water supply Process water and industrial applications Swimming pools Food and beverage industry Performance Profile of the Testomat 2000 for Chlorine Dioxide Measurement Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 1 minute reaction time 2 independently programmable limit contacts for monitoring and control tasks; measurement recording with optional plug-in card (SK910 current interface) for a point or chart recorder (0/4–20 mA) or SD-card data logger Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval mode) Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CLT – Online Photometer for Total Chlorine Monitoring Continuous analysis of total and free chlorine The Testomat 2000 CLT by Heyl continuously monitors total chlorine content in water. With automatic dosing of three reagents and menu-guided operation, it delivers precise measurements in the range of 0–2.5 mg/l. The device can be switched to free chlorine measurement when required, providing high flexibility. The wet-chemical measurement process of the Testomat 2000 CLT produces a color change in the sample, the intensity of which is measured photometrically to provide precise and reliable results. Two independently programmable limit contacts with adjustable hysteresis enable direct monitoring and control functions in the process. By switching external solenoid valves, two measuring points can be monitored. Technical Highlights of the Testomat 2000 Chlorine The Testomat 2000 CLT features intuitive operation and programming with freely selectable measurement intervals, external triggering options, or quantity-dependent measurement via contact water meter. Operation is performed via a plain-text display. High measurement accuracy is guaranteed by the precise piston dosing pump. Where can the Testomat 2000 CLT be used? Monitoring chlorination systems in drinking water Monitoring chlorination systems in swimming pool applications Protection of reverse osmosis membranes Monitoring chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLT Analysis using automatic dosing of 3 reagents Display of the analysis result after approximately 1 minute Two independently programmable limit contacts for monitoring and control tasks; result recording via optical plug-in card (current interface SK910) for point or line recorders (0/4–20 mA) or SD card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CLT Self Clean – Analyzer with Self-Cleaning for Total Chlorine Continuous Total Chlorine Analysis with Automatic Measuring Chamber Cleaning for Reliable Water Quality Control The Testomat 2000 CLT Self Clean is an analyzer for continuous monitoring of total chlorine in the range of 0.00 to 2.50 mg/l (ppm) in water, with an additional cleaning function for the measuring chamber. This ensures minimal maintenance effort. The device can also be switched to measure free chlorine in the same range (0.00 to 2.50 mg/l). By automatically dosing three reagents and using photometric measurement, the system delivers reliable results after a short reaction time. After a preset number of measurement cycles, the measuring chamber is automatically flushed and treated with a cleaning or disinfecting solution to prevent deposits or measurement interference. This improves long-term stability of the results and reduces maintenance requirements. Technical Highlights of the Testomat 2000 CLT Self Clean The device uses a photometric measurement method with automatic dosing of three reagents for precise determination of total chlorine. The plain-text display with menu-guided navigation allows easy configuration of measurement intervals, external triggers, quantity-dependent measurement modes, and threshold values. Two independently programmable limit values with hysteresis enable direct monitoring and control functions in the process. Applications of the Testomat 2000 CLT Self Clean Monitoring of chlorination systems in drinking water Monitoring of chlorination systems in swimming pools Protection of reverse osmosis membranes Monitoring of chlorine-containing biocides and conditioning agents Performance Profile of the Testomat 2000 CLT Self Clean Analysis via automatic dosing of 3 reagents Display of analysis results after a reaction time of approx. 1 minute Two independently programmable limit contacts for monitoring and control tasks; analysis recording with optional plug-in card (current interface SK910) for a point or strip chart recorder (0/4–20 mA) or SD-Card data logger Testomat 2000® Simple, menu-guided operation and programming via plain-text display High measurement accuracy through precise piston dosing pump Analysis trigger: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 invalid analyses) and configurable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CrVI (High Measurement Range) – Analysis Device for Chromate and CrVI Extended analysis of chromate and CrVI for safe process monitoring The Testomat 2000 CrVI (High Measurement Range) is an analysis device for continuous monitoring of chromate and CrVI content in water with an extended measurement range (chromate up to 11.15 mg/L, CrVI up to 5.0 mg/L). Automated reagent addition and short reaction times provide fast and reliable results. The device allows continuous monitoring of chromate and CrVI. The photometric measurement method uses two automatically added reagents, ensuring reliable detection even at high concentrations. Measurement results are available within minutes. Two freely programmable limit values with hysteresis enable process alarms or control functions. Optionally, data can be recorded via 4–20 mA signal, recorder card, or SD-Card logger. Functional strengths of the T 2000 CrVI with extended measurement range from Heyl The device combines robust photometry with automatic reagent addition and provides precise measurement even at high concentrations. Easily programmable measurement intervals and short reaction times ensure efficient operation. Limit contacts allow direct process control or alarms, while optional interfaces enable seamless data logging. Typical applications of the online Testomat 2000 CrVI Monitoring chromate content in wastewater from electroplating facilities Monitoring wastewater in metalworking industries Performance profile of the T 2000 for chromate / CrVI measurement Analysis using automatic addition of 2 reagents Display of measurement result after approx. 2 minutes (measurement time without rinsing) Two independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy thanks to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External triggering Dynamic (exhaustion-dependent interval operation) Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 CrVI (Standard) – Reliable Monitoring of Chromate and CrVI Reliable control of Chromate and Chromium VI in process water with the T 2000 from Heyl The Testomat 2000 CrVI (Standard) is an online analysis device for monitoring Chromate (CrO42-) concentrations from 0 to 2.0 mg/l or Chromium VI (CrVI) concentrations from 0 to 1.0 mg/l. It uses a photometric analysis method with automatic reagent addition and delivers results after a short reaction time directly for process control. The device operates with a photometric measurement principle, where two reagents are automatically dosed. After approximately two minutes of reaction time, the measurement results are available. Two independently programmable limit contacts allow direct integration into monitoring or control systems. Technical Features of the Testomat 2000 CrVI The photometric measurement principle combined with automated reagent addition distinguishes the Testomat 2000 CrVI. This allows reliable measurement of Chromate and CrVI. Measurement data can also be logged via optional interfaces. The clear-text menu simplifies configuration and operation. Typical Applications of the T 2000 CrVI Monitoring chromate content in wastewater from electroplating facilities Control of wastewater in the metalworking industry Why is Monitoring Chromate and Chromium VI Important? Chromium VI is highly toxic and subject to strict legal limits. Continuous monitoring of Chromate and CrVI allows early detection of limit exceedances, protects humans and the environment, and ensures compliance with environmental regulations in process and wastewater systems. Performance Profile of the Testomat 2000 CrVI Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 2 minutes of reaction time (excluding flushing time) 2 independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via clear-text display High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaustion-dependent interval operation) Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 faulty analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance request
Testomat 2000 DUO – Measurement of Key Water Parameters Heyl Testomat with two measurement points for analyzing various water parameters The Testomat 2000 DUO is an online analysis device that monitors two measurement points simultaneously, allowing parallel evaluation of different water parameters. Possible measured parameters include: Water hardness Carbonate hardness p-value (pH) Minus m-value The Testomat 2000 DUO expands the capabilities of traditional analysis devices by evaluating two measurement points at the same time. Automatic switching between measurement points reduces installation and operation effort, as no separate control unit is required. Measurement parameters are selected using easily replaceable indicators. Technical Strengths of the Testomat 2000 DUO The device uses automatic titration combined with a precise piston dosing pump, enabling exact measurements of different parameters at two measurement points. Various operating modes such as automatic intervals, external control, dynamic intervals, or volume-dependent measurements adapt the device to different plant configurations. Versatile Applications of the T 2000 DUO The Testomat 2000 DUO by Heyl is suitable for monitoring in water treatment, water blending, and drinking water systems. Please note that a Viton DosiClip is required for measuring carbonate hardness. This must be specified when ordering a DUO device. Performance Profile of the Testomat 2000 DUO Monitoring of 2 measurement points with different indicator types, e.g., water hardness with different measurement ranges or water and carbonate hardness Automatic measurement point switching Input to restrict to measurement point 1 available Menu-guided operation and programming with plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, p-value via indicator selection Choice of hardness units: °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval mode (interval pause 0–99 minutes) External control Dynamic (exhaustion-dependent interval operation) Volume-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 failed analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for maintenance requests
Testomat 2000 Fe – Real-Time Iron Measurement in Water Reliable iron monitoring for process water with the online analysis device T 2000 by Heyl The Testomat 2000 Fe is an online analysis device for the continuous determination of dissolved iron in water (iron-II + iron-III). It operates with automatic reagent dosing and photometric analysis, providing consistently stable and reliable measurement results. The Testomat 2000 Fe is used wherever iron concentration must be monitored to prevent deposits, discoloration, or disruptions in downstream processes. Through automatic analysis, the device regularly delivers current measurements, allowing early responses to rising iron concentrations. Limit exceedances can thus be detected immediately and used to trigger alarms or control actions. Technical Strengths of the Testomat 2000 Fe The Testomat 2000 Fe uses a photometric measurement method in which iron-II and iron-III are evaluated after automatic addition of defined reagents. The analysis is carried out using two reagents, and after a reaction time of approximately 7 minutes (pure measurement time without rinsing), the result is displayed. Measurements are performed independently at set intervals or via external triggers. Technical features include two independently configurable limit contacts and various signal outputs for further processing of measurement values. Internal diagnostic functions support safe operation and facilitate maintenance planning. Optional interfaces allow connection to process control systems or external data loggers. Applications for the Testomat 2000 Iron De-icing systems Monitoring of de-icing systems and well water Control of operational and drinking water streams Why Iron Measurement is Crucial in Water Treatment Dissolved iron is initially invisible in water but can lead to deposits, discoloration, and disruptions in downstream processes through oxidation. Even low concentrations cause fouling of filters, pipelines, and membranes. Continuous iron measurement enables early detection of limit exceedances, protects plant components, and ensures consistent water quality in process, operational, and drinking water applications. Performance Profile of the Testomat 2000 Fe Analysis using automatic dosing of two reagents Display of the measurement result after approximately 7 minutes (measurement time without rinsing) Two independently programmable limit contacts for monitoring and control tasks Menu-guided operation and programming via plain-text display High measurement accuracy due to precise piston dosing pump Analysis triggering: Automatic interval operation (interval pauses adjustable from 0–99 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 PO4 – Precise Online Phosphate Analyzer Continuous monitoring of ortho-phosphate, reliable and automated The Testomat 2000 PO4 is an analysis device that continuously and reliably monitors ortho-phosphate levels in the range of 0 to 10.0 mg/L (ppm). The measurement is based on molybdenum blue photometry. A chemical reaction produces a characteristic steel-blue color change in the sample. Two reagents are automatically added, and after a short reaction time of approximately ten minutes, the Testomat provides a precise result. With menu-guided operation, plain-text display, and selectable units (ppm or mg/L), the device is ideal for continuous monitoring tasks. Features of the Testomat With automatic reagent supply, programmable measurement intervals, and two independent setpoints with hysteresis, the device delivers accurate results at all times. Its compact design allows flexible installation directly at the measurement point. Digital interfaces enable seamless integration into existing control and monitoring systems. Where can the device be used? Process water monitoring Production water treatment Treated wastewater (wastewater treatment plants, biogas plants) Online environmental analytics Performance profile of the T 2000 PO4 from Heyl Analysis using automatic addition of 2 reagents Display of measurement result after approx. 10 minutes (measurement time without rinsing) Menu-guided operation and programming via plain-text display Selectable units in ppm or mg/L Analysis triggering: Automatic interval mode (interval pause adjustable from 0–255 minutes) External triggering Quantity-dependent via contact water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests
Testomat 2000 – Online Analysis Device for Polyacrylates Reliable online analyzer for monitoring polymer concentrations in water treatment The Testomat 2000 Polymer is an online analysis device for monitoring polyacrylate content in the range of 0 to 50 mg/L (ppm), with a standard product-specific factor of 1.00. The Testomat 2000 Polymer is a professional online analyzer for automatic analysis of polyacrylate content in water. Photometric measurement is based on the addition of two reagents. After a reaction time of approx. 7 minutes, the result is displayed digitally and can be used for control or documentation. With menu-guided operation, unit selection (ppm or mg/L), and versatile triggering options, the analysis process is efficient and reliable. It is suitable for monitoring conditioning agents in cooling and heating circuits. Technical Features of the Testomat 2000 Polymer Automatic interval measurements, external control options, and programmable switching functions allow adaptation to various process requirements. Two independent switching points with hysteresis, adjustable maintenance intervals, and internal error documentation increase reliability in continuous operation. Performance Profile of the T 2000 Polymer Analysis via automatic dosing of 2 reagents Measurement result displayed after approx. 7 minutes reaction time (measurement time without rinsing) Menu-guided operation and programming via plain-text display Selectable units in ppm or mg/L Analysis triggering: Automatic interval mode (interval pause adjustable from 0–255 minutes) External triggering Quantity-dependent via contact water meter Two independent limits with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measurement points (switching via external solenoid valves) Internal error documentation Programmable service address Programmable maintenance interval for maintenance requests Why is monitoring polyacrylates in water treatment important? Monitoring polymers ensures optimal dosing of conditioning agents, prevents deposits and fouling, and reliably protects water treatment equipment from operational disruptions. Chemical dosing must be monitored with a Testomat because its effectiveness is highly concentration-dependent. Continuous online monitoring ensures dosing stays within the optimal range, prevents under- or overdosing, and protects equipment, processes, and water quality reliably.
Testomat 2000 Self clean – Analyzer with Automatic Cleaning Water Hardness Meter from Heyl with Automatic Measurement Chamber Cleaning for Consistently Stable Results The Testomat 2000 Self clean is a specialized version of the Testomat 2000 with an additional dosing pump for adding a cleaning solution after analysis. After a set number of analyses, the measurement chamber is automatically rinsed and a cleaning solution is dosed to remove deposits in the measurement chamber and drain hose. The chamber content is discharged after a short reaction time, and the system is rinsed several more times. This ensures long-term measurement accuracy and device performance. The device measures various water parameters such as residual and total hardness, carbonate hardness, p-value, and minus m-value, with selectable units in °dH, °f, ppm CaCO3, or mmol/l. Special features of the Testomat 2000 Self clean With freely selectable hardness units, automatic interval control, and various external triggering options, the device can flexibly adapt to different measurement tasks. Two programmable limit values with hysteresis enhance process control, while the intuitive menu reduces operating errors and simplifies commissioning. Applications for the Testomat 2000 Self clean Boiler feed water Water treatment Cooling towers Swimming pools Functions and performance features of the Testomat 2000 Self clean Easy menu-guided operation and programming via plain text display Measurement of residual hardness, total hardness, carbonate hardness, minus m-value, and p-value selectable via indicator Choice of hardness units in °dH, °f, ppm CaCO3, or mmol/l High measurement accuracy through precise piston dosing pump Analysis triggering: Automatic interval operation (interval pause adjustable from 0–99 minutes) External control Dynamic (exhaust-dependent interval operation) Flow-dependent via water meter Two independent limit values with hysteresis (1, 2, or 3 bad analyses) and adjustable switching functions Monitoring of two measuring points (switching via external solenoid valves) Internal error documentation Programmable service address Indicator quantities: 100 and 500 ml bottles Programmable maintenance interval for service request