Filter products
Our portable multi-parameter measuring device with innovative high-resolution colour display is suitable for working in all conditions and offers you an integrated user-friendly guide in the form of the set-up and calibration mode. This allows the user to easily and intuitively use the instrument at any time. The meter has automatic pH calibration with USA and NIST buffers with up to three points for pH and one point for ORP. You are supported by an intuitive symbolism on the backlit screen, including the indication of the measurement stability (adjustable) and any errors. Another advantage is that the multi-parameter meter is delivered in our professional measuring case, which contains the selected measuring electrodes, as well as our respective buffer solutions and the instructions. Complementary advantages of the Professional Plus version: GLP functions: Date and time, recall of calibration data and "Calibration due" function Integrated data logger for up to 1000 data, automatic and manual PC connection via USB for evaluation of measurement data (Micro-USB on the instrument side) via Data Link+ software Automatic brightness control of the display (prolongs battery life) Only 6 keys for easy control of all functions of the unit 230V power supply unit
Pump cover, spare part for the Testomat LIMIT
Pump cylinder, spare part for the Testomat LIMIT
Manufacturer article number: 50014443 (ORP 51) Replacement electrode for Neomeris Professional Redox/Temp. pocket tester with exchangeable probe, IP67. Article no.: 880845
The reducing connector 10-6 is a spare part for Testomat 2000® / ECO® and Titromat®.
The regulator plug T2000, complete, is a spare part for Testomat 2000®.
Regulator/filter intake, complete, is a spare part for für Testomat® devices: Testomat 2000®/ Testomat® EVO TH/ Testomat ECO®/ Titromat®
Maintenance & Repair Kit for TESTOMAT® / TITROMAT® Comprehensive Maintenance and Repair Kit for Professional Servicing The maintenance and repair kit combines a wide range of spare and wear parts for Testomat® and Titromat® devices. The kit covers all components required for service work on the Testomat device family and the Titromat from Heyl. The kit includes: 10 x O-Ring 20x2 10 x O-Ring 10.82x1.78 5 x O-Ring 4.47x1.78 5 x O-Ring 18x2 EPDM 20 x Flat Gasket 24x2 5 x Inlet Filter Screen 19.5dx25 5 x Flow Regulator Core 2 x Spring for Inlet 15 x Plugs for Measuring Chamber 6 x Fuse, T 0.08A 6 x Fuse, T 0.1A 6 x Fuse, T 0.16A 6 x Fuse, T 0.2A 6 x Fuse, T 0.315A 6 x Fuse, T 1.0A 6 x Fuse M4A 20 x Sight Glass 30x3 3 x Screw Cap with T2000 Insert 4 x Screw M3x40 1 x Suction Hose 1 x Pressure Hose 6 x Various Pipes 1 x Cleaning Brush Set 2 x Plug-In Elbow Connectors 2 x Magnetic Stirring Cores Professional Maintenance and Repair of Testomat® and Titromat® Devices The maintenance and repair kit for TESTOMAT® and TITROMAT® was specifically designed for professional service use. It combines a comprehensive selection of spare and wear parts needed for regular maintenance, servicing, and repairs of the device family. Thanks to its complete equipment, the kit is ideal for service technicians, maintenance staff, and operators who want to minimize downtime and carry out maintenance efficiently on-site. Advantages of the Maintenance & Repair Kit for Service Use The repair kit covers almost all typical wear and spare parts used in the operation of Testomat® and Titromat® analysis devices. From seals and O-rings to fuses, hoses, sight glasses, and cleaning accessories, everything is organized clearly in one kit. This allows for fast troubleshooting, reduces downtime, and ensures consistently high measurement accuracy and operational reliability. At the same time, the kit simplifies spare part storage and supports an economical maintenance strategy.
Repair and Service Kit for Testomat® 808 from Heyl Complete Set for Maintenance, Repair, and On-Site Spare Part Supply The Testomat® 808 repair and service kit contains all essential wear and spare parts for efficient maintenance of your Testomat® 808 device. Ideal for service teams performing repairs directly at the customer site or in the facility. The kit includes all components necessary for repairs and maintenance. The kit contains: 8x O-Ring 3.68 x 1.78 8x O-Ring 1.78 x 1.78 8x O-Ring 4.5 x 1.5 8x Flat Gasket 24 x 2 1x Pump Head 4x 500ml Container with Screw Cap 1x 100ml Container with Screw Cap 1x Cleaning Brush Set 4x Elbow Screw Connectors 6x Fuse, T 0.1 A 6x Fuse, T 0.2 A 6x Fuse, T 1.0 A 6x Fuse, T 4 A 6x Sight Glass 30x3 2x Pipe, L = 53 mm 2x Pipe, L = 140 mm 1x Optical Board 1x SUB-D Null Modem Cable 1x USB-Serial Adapter 2x Dosing Needle 4x Hose Adapter 2x Magnetic Stirring Core 8x Screws M3x12 4x Screws M3x40 1x LED Holder 1x Solenoid Valve 1x Documentation/Software Complete Solution for On-Site Maintenance, Repair, and Service The Testomat® 808 repair and service kit was specifically designed for fast and professional device maintenance. It includes all relevant spare and wear parts needed for routine maintenance, repairs, or unplanned service calls. Thanks to its comprehensive contents, the kit is ideal for service teams, maintenance staff, and operators performing repairs directly at the customer site or facility. This minimizes downtime and ensures the Testomat® 808 remains fully operational at all times. Advantages of the Repair and Service Kit for Testomat® 808 The service kit enables efficient and structured maintenance because all necessary spare parts are bundled in a single set. In addition to gaskets, fuses, and hoses, the kit also includes key components such as the pump head, solenoid valve, optical board, and other essential accessories for the Testomat 808. This allows for rapid troubleshooting and repair without the need for additional spare parts, significantly reducing service times and supporting economical operation. Regular maintenance with original parts ensures high measurement accuracy and long-term operational reliability of the Testomat® 808.
Contents: 1 x 37570 Solenoid valve complete Testomat® 808 2 x 37580 Insert with screw cap and suction tube 100ml bottle 1 x 37859 double pump head Testomat® 808 1 x 31972 SUB-D null modem cable, 9-pin, 2 x socket, 3m 4 x 37579 Insert with screw cap and suction tube 500ml bottle 2 x 40050 Magnetic stirring core 4 x 37538 Tube adapter Testomat® 808 4 x 40157 Angle screw-in connector, G1/8"-6 2 x 37543 Pipe, PE, D=6 d=4 L=53mm 2 x 37544 Pipe, PE, D=6 d=4 L=140mm 6 x 40170 Viewing window 30x3 6 x 31595 Fuse solder-in, TR5, T0,1A 6 x 31592 Fuse solder-in, TR5, T1,0A 6 x 31584 Fuse, solder-in, TR5, T0.2A 6 x 31585 fuse, T0,315A 8 x 33797 O-ring 3,68 x 1,78 8 x 31666 Fuse G-, 5x20mm, T4A 8 x 33777 Flat gasket 24x2 EPDM 70 4 x 33253 Screw M3x40, A2, DIN 965 8 x 33246 pan-head screw M3x12 DIN 7985H A2 8 x 11264 O-ring 4.5 x 1.5 8 x 11245 O-ring 1,78x1,78 1 x 32286 Adapter USB > Serial -length 1.1 meter 1 x 32287 Cleaning brush set 1 x 37498 USB stick with software tool for T808 and maintenance manual 2 x 37621 Dosing needle Testomat® 808 completeTranslated with www.DeepL.com/Translator (free version)
Replacement pump-LIMIT TH complete - compatible with the Testomat LIMIT TH
The Selfclean function from Heyl allows cleaning cycles to be carried out independently through an additional dosing pump. Through continuous cleaning, it is ensured that the measurement results are not distorted. In addition, maintenance effort is reduced and the lifespan of your Testomat LIMIT is extended. Delivery includes The expansion kit (item no. 40681) for installing a second pump for the cleaning function consists of the following components: 1) Pump with motor (fully pre-assembled) 2) 1 beak valve (item no. 33805) at the outlet) 3) 1 large O-ring ø 11 x 1 (item no. 33716) 4) 1 small O-ring ø 1.78 x 1,78 (item no. 11245) 5) 1 casing (item no. 33752) 6) 1 beak valve (item no.. 33805) at the inlet 7) 2 screws (item no. 33028) for attaching the pump (already provided) 8) 1 tube 250 mm (item no. 40433) Suction side to the bottle with cleaning fluid 9) 1 tube 250 mm (item no. 40433) Pressure side to the measuring chamber 10) 2 screws (item no. 33028) for attachment to the control unit (already provided) Download Einbauanleitung_Testomat Limit_SelfClean-Pumpe Installation instructions_Testomat Limit_SelfClean pump Instructions de installation_Pompe Testomat Limit_SelfClean Installatiehandleiding_Testomat Limit_SelfClean-pomp
Ribbon cable 10 pole with EMI filter clamp 240 mm, 2 x 5 pol is a spare part for Testomat 2000® / Testomat ECO® / Titromat.
Ribbon cable 26 pol. with ferrite,250 mm, 2 x 13 pol. socket plug, is a spare part for Testomat 2000® / Testomat ECO® / Titromat
Complete rotary field recording for the Testomat LIMIT
Schraubglas mit Eichmaß für Polyamine Testbstecke.
Device Screw cap GL32 - with hole is a spare part for 100ml and 500 ml bottles of Testomat 2000® / Testomat ECO® / Testomat® EVO TH / T808 and Titromat.
Screw cap with insert and suction tube for 500 ml bottle complete - T2000/ECO/EVO/Titromat
Screw connector G1/8´´-6 is a spare part for Testomat 2000® / ECO® and Titromat®.
Screw connector T 3/8´´-10 is a spare part for Testomat 2000® / ECO® and Titromat®.
Screw-in connector 1/4 x 1/8 for the Testomat LIMIT