Filter products
Drain hose 1/4, spare part for the Testomat LIMIT
The duckbill valve is a spare part for the Testomat LIMIT
Chamber holder, complete (without valves) for Testomat® DUO
Feed connector is a spare part for pressure regulator of Testomat® devices for: Testomat 2000®/ Testomat® EVO TH/ Testomat ECO®/ Titromat®
Spare part for candle filter housing of Testomat® 808
Filter intake for pressure regulator of our Testomat® devices Testomat 2000®/ Testomat® EVO TH/ Testomat ECO®/ Titromat®
Spare part for measure chamber of Testomat® devices: Flat gasket 24×2 EPDM 70Two flat gaskets are required for replacement in the measuring chamber.
The flow regulator DN 15, 1/2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 25, 1" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 40, 1 1/2 " is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 50, 2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 65, 2 1/2" is suitable for the NEOMERIS Softmaster RS.
The flow regulator DN 80, 3" is suitable for the NEOMERIS Softmaster RS.
FLOWClip® dosing pump for Testomat® 2000 self clean and Testomat® 2000 CLT self clean.Reliable diaphragm pump for automatic dosing of cleaning agents into the measuring chamber – for more thorough cleaning and stable measuring quality. Delivery rate: 0.1 l/min · self-priming up to 3 mWS · mounting: 35 mm DIN top-hat rail. Buy FLOWClip dosing pump from Heyl online Automatic cleaning of the measuring chamber The FLOWClip® dosing pump was specially developed for our Testomat® 2000 self clean and Testomat® 2000 CLT self clean devices to automatically fill the measuring chamber system with cleaning solution. Compared to rinsing with normal water, the measuring chamber is cleaned more thoroughly, deposits are reduced and process reliability is increased. The pump delivers a consistent flow thanks to its precise diaphragm technology and automatically fills the device's measuring chamber system with cleaning solution, thereby cleaning the measuring chamber. Why buy the original FLOWClip dosing pump for your Testomat 2000 self clean? Ready for immediate use upon delivery – minimal downtime Easy to mount on a 35 mm DIN top-hat rail Low-maintenance design – low operating costs and high availability Compatible with Testomat® 2000 self clean and Testomat® 2000 CLT self clean – easy integration into existing installations Areas of application Automatic dosing of cleaning agents into the measuring chamber of the Testomat® 2000 self clean / Testomat® 2000 CLT self clean Optimisation of measuring chamber hygiene Your advantages at a glance Constant dosing performance: 0.1 l/min for controlled, reproducible results Self-priming: up to 3 mWS Stable process conditions: Automatic cleaning of the measuring chamber for reliable measured values Quick installation: Mounting on a 35 mm DIN top-hat rail reduces installation effort Range of applications: Suitable for cleaning agents (item number: 151105 / Testomat® Self Clean cleaning solution 500 ml) Low maintenance: For long running times and low service intervals Important installation information The pump is ready for operation upon delivery Observe the technical data and keep the suction line as short as possible (optimised suction behaviour) Check connections for leaks and extend flushing times if necessary Can be used in Testomat devices of the 2000 and TITROMAT series The pump is generally low-maintenance – ideal for continuous system operation Maintenance & service Check the following at regular intervals: Tightness of hose connections, screw connections, etc. Contamination of hose lines (clean or replace if necessary). Tip: A preventive check as part of regular system maintenance increases operational safety and extends the service life of the components. Why should I buy the FLOWClip® dosing pump? Original spare part from Heyl Greater process stability: Clean measuring chambers deliver reliable measurements – reducing false alarms and rework Less downtime: Plug and play, quick installation, low maintenance Predictable costs: Durable diaphragm technology, reduced service calls Order the FLOWClip® dosing pump now Automate measuring chamber cleaning – for stable measurements, higher system availability and less maintenance. Secure a 3% online shop discount on all Heyl items. Frequently Asked Questions Is the dosing pump ready for use immediately after delivery? Yes. The FLOWClip® is delivered ready for operation. Simply connect it, keep the suction line as short as possible, and check all connections for leaks. How can I ensure reliable suction? Ensure reliable suction by keeping the suction line as short as possible and checking all hose connections for leaks. How much maintenance is required? The pump is low-maintenance. We recommend regularly checking hose connections and lines for leaks or contamination.
The fuse T0,16 A is a spare part for Testomat 2000® / ECO® and Titromat®.
The fuse T1,0 A is a spare part for Testomat 2000® / ECO® and Titromat®.