By using these NeoTec Slave relay modules, potential-free relay contacts are added to the overall system. All relay contacts can be freely assigned to the incoming measuring signals and can therefore be used, for example, for limit value-related control concepts or measured value-related messages.Advantages:individual implementation of: alarm message based on received measured values and/or status messages switching contacts for simple valve control compact design for top hat rail mounting when using several modules only one power supply is necessary modular expandable according to process requirements
The NeoTec Slave RS232 enables the integration of further devices. For example, the Testomat® LAB/Modul and Testomat® EVO TH series. The software of the NeoTecMaster® is already pre-parameterized ex works for the device types named here and immediately enables the reception of measurement results and status messages as well as their further processing.Advantages:compact design for top hat rail mounting when using several modules only one power supply is necessary can be added module by module up to max. 7 pieces
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation Integration of the Testomat® device world Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant Contents: NeoTecMaster® 5 inch - 4 channel system (optionally expandable to 8 channels) with Modbus interface and RS232 input for data communicationNeoTec Slave 4-20mA module (inputs: 8x 20mA)NeoTecMaster® IP66 housing for 5" display, light grey with front foilUSB stick for NeoTecMaster® 8GBInstallation of NeoTecMaster® in housing incl. parameterisation and cabling of the NeoTecMaster®Universal power supply 24V/6A DC (100-240V AC) (144 Watt)
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation Integration of the Testomat® device world Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant
The housing for holding the master or display unit as well as up to 6 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components.
The housing for holding the master or display unit as well as up to 10 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components.
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A ORP sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
The ORP sensor from the NeoTec Select Standard product range with Modbus module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with 4 - 20 mA module permanently encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with Modbus modul encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
A pH sensor from the NeoTec Select Standard product range with Modbus modul encapsulated in the sensor body.Advantages:Preconfigured for NeoTecMaster® Industry standard Can be used as immersion probe
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 500.000 μS (0 - 500 mS)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
Analogue and digital communication for more process visibility• Modbus or 4-20 mA sensor output available• Configuration and calibration can be done using web based software Corrosion, Coating and Fouling Resistant• Noryl body has a wide solvent tolerance and temperature stability to 105°C (used with flow cell 80°C, with integrated 4-20mA output or Modbus 70°C) Mounting• Can be installed in line using the specific flow cell or submersed via the 3/4" MNPT thread Wide Measurement Range• Can measure conductivity from 0 – 2.000.000 μS (0 - 2 S)
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing Safety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General information Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °C From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808! Optional accessories: NeoTecMaster unit hood
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified. It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® functionalities of both devices: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® EVO TH: High-precision titration by means of piston metering pump LCD graphic display Multilingual menu with easy switching (internal programming is retained) External clear / acknowledge input Free programmable password Range monitoring (fall below limit value1 / exceed limit value 2) Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure) Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 100 and 500 ml bottles Analysis trigger: automatic interval operation (0-99 minutes) depending on quantity via contact water meter Performance profil Testomat® LAB CL: High-precision peristaltic pumps Reliable and low-maintenance operation Minimal reagent and water consumption Analog output 4 - 20 mA for transmission of measured values RS232 interface for transmission of measured values & fault messages Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch, Portoguese Compact design Common alarm output Optimised reagents: Only 2 reagents for the determination of total chlorine Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly Analysis triggering: Automatic interval operation (interval pause adjustable from 10-60 minutes) Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand start Optional accessories available: OLED display for Testomat® LAB Protective cover to increase the IP protection class of the Testomat® LAB NeoTecMaster instrument cover