Testomat® EVO TH + LAB CL with NeoTecMaster® - value-added package

Product number: 851065

€8,359.41*

Please log in to receive your conditions.

Available in 42 days, delivery time 1-2 days

Indicators / Reagents

Testomat®

NeoTecMaster®


Product number: 851065
GTIN: 4260682380159
Measurement parameters: Water hardness (residual total hardness, free or total chlorine and your existing Modbus RTU measurement technology.
Measuring range: 0.89 - 448 ppm total hardness | 0 to 5 mg/l total or free chlorine
Menu navigation: Testomat EVO TH: German, English, French, Mandarin (Chinese), Dutch, Portuguese, Polish, Russian, Spanish, Czech, Turkish (other languages on request) | LAB CL Service Monitor: German, English, French, Dutch, Portuguese | NeoTecMaster®: German, English, Chinese, Russian, French (other languages on request)
Our comment: Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 | only applies to the Testomat EVO TH and not to the other components of the package
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.

Leasing Example

174,63 € non-binding
Monthly Rate (60 Rates)
Prices excl. VAT

Further rate options by choosing the payment method Leasing

Product information "Testomat® EVO TH + LAB CL with NeoTecMaster® - value-added package"
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.  
It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).

In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. 

The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and  Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). 

The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. 

Further advantages of the NeoTecMaster: 

  • Simple operation 
  • Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL 
  • Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing 
  • Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)
  • Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format 

In addition, there are proven Testomat® functionalities of both devices: 

  • Optimised water detection based on an optical measuring method 
  • RS232 interface for transmission of measured values and error messages 
  • Import and export of settings (basic programming) 
  • Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) 
  • Firmware update via SD card 
  • Integrated self-test with continuous monitoring 
  • Automatic venting of the indicator line 
Performance profil Testomat® EVO TH

  • High-precision titration by means of piston metering pump 
  • LCD graphic display
  • Multilingual menu with easy switching (internal programming is retained)
  • External clear / acknowledge input
  • Free programmable password
  • Range monitoring (fall below limit value1 / exceed limit value 2)
  • Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)
  • Reliable and low-maintenance operation 
  • Minimal indicator and water consumption 
  • Analogue output 4 - 20 mA for transmission of measured values 
  • Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l 
  • Collective alarm output 
  • Indicator quantities: 100 and 500 ml bottles 
  • Analysis trigger:
  • automatic interval operation (0-99 minutes)
  • depending on quantity via contact water meter 

Performance profil Testomat® LAB CL: 
  • High-precision peristaltic pumps
  • Reliable and low-maintenance operation
  • Minimal reagent and water consumption
  • Analog output 4 - 20 mA for transmission of measured values
  • RS232 interface for transmission of measured values & fault messages
  • Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) 
  • Multilingual software menu in German, English, French, Dutch, Portoguese
  • Compact design 
  • Common alarm output
  • Optimised reagents: Only 2 reagents for the determination of total chlorine
  • Optimised reagent set: filling quantities are coordinated so that the reagent set is used up almost evenly
Analysis triggering:
  • Automatic interval operation (interval pause adjustable from 10-60 minutes)
  • Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
  • External analysis input (start/stop)
  • Hand start
Optional accessories available: 
  • OLED display for Testomat® LAB
  • Protective cover to increase the IP protection class of the Testomat® LAB
  • NeoTecMaster instrument cover

Dimensions

Height 31 cm
Length 63 cm
Width 45 cm

Weight

Weight 20 kg

Other attributes

Technical data
Testomat® EVO TH:
Supply voltage: switching power supply 100-240 VAC, 100-353 VDC
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa (after removal of the valve body)
Weight: approx. 9,0 kg
Menu Language:
German, English, French, Dutch, Spanish, Turkish, Chinese, Czech, Russian, Polish, Portuguese (others on request)
Measuring range: Water hardness: 0.89 - 448 ppm


Testomat® LAB CL:
Operating voltage:

24 VDC
Power consumption: Max. 1 A, without external load
Protection class: I
Protection: IP 40 (when using the optionally available device cover, IP43)
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     270 x 350 x 147 mm
Operating pressure: 1 to 8 bar / 1x105 to 8x105 Pa or 0.3* to 1 bar / 1x105 to 1x105 Pa (*after removing the regulator core)
Weight: approx. 4.35 kg
Menu Language: (Servicemonitor) German, English, French, Dutch
Measuring range:0-5 mg/l (ppm) free chlorine | 0-5 mg/l (ppm) total chlorine 

NeoTecMaster®:
  • 5 inch display with integrated resitive touchscreen 
  • 24VDC power supply 
  • Display of four measured values (8 measured values, see product page)
  • RS232 input for connection of a Testomat® LAB and EVO TH 
  • RS485 input for connection of Modbus RTU sensors
  • USB input (for data storage) 
  • Ethernet interface for visualization of the actual status 
  • Dimensions (W x H x D) 180 x 135 x 48 mm

Recommended accessories

NeoTecMaster® enclosure IP66 for 7" screen, light grey
Product number: 850968
The housing for holding the master or display unit as well as up to 10 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components. 

€182.25*
NeoTecMaster® enclosure IP66 for 5" screen, light grey
Product number: 850967
The housing for holding the master or display unit as well as up to 6 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components. 

Price on request
Instrument cover for Testomat® LAB instruments
Product number: 37798
Recommended for Testomat® LAB instruments which are exposed to sunlight.

€536.10*
Testomat® LAB OLED display module for measured value visualization
Product number: 37764
256x64 2,8", yellowFeatures: When the device is switched on with the display plugged in, the installed software version is displayed during the boot process. This  allows you to visually check the current software version after a software update. After a measurement has been completed, the measurement result is  shown in the selected display unit. The display value is retained until the end of the next measurement and is then updated to the new measured value. If a fault occurs during the last measurement, the display shows “xx x x x selected display unit”. If it is a temporary fault, the Alarm function key flashes at the same time (see Temporary faults in the manual). In this case, the device will start a new measurement once the programmed analysis interval has expired. If the error is still present, the indication on the display remains and  the Alarm function key remains illuminated. In this case, no further measurements are made during programmed analysis interval and the device switches to standby mode. If the fault is no longer present, the measurement result is shown on the display once the measurement has been completed and the device switches back to normal operating mode. 

€560.10*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€134.60*