General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: Screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-12-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: HT glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Extra codes: Salt reserve, with integrated Pt1000Order code: 201020/79-12-10-18/837, 841
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: screw head Pg13.5Extra codes: Salt reserveOrder code: 201020/79-18-10-22/837
General descriptionThe electrodes are characterised by high mechanical and chemical resistance. Due to the stable PVDF body, there is practically no risk of the sensor breaking. The electrolyte of these combination electrodes guarantees a stable measured value, even in critical media containing sulphite.A Pt1000 temperature sensor is integrated. Depending on the application, the electrodes can be manufactured as pH or redox electrodes. An open annular gap diaphragm is used as the diaphragm.Areas of applicationChemical industryWaste water treatmentSewage treatmentPaper industrySelected version:Basic type: JUMO tecLine PRO pH combination electrodeBasic type extension: Process electrodeActive part: UW glassDiaphragm: annular gap diaphragmElectrical connection to electrode: VP plug-in head Pg13.5Type supplements: Salt reserve, with integrated Pt1000Order code: 201020/79-18-10/837, 841
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: platinum capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-07-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, glass shaftActive part: gold capDiaphragm: 1x zirconium dioxideElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-32-07-22-120/837
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837
High-quality industrial electrodesProcess/industrial applicationswith gold tipdifferent insertion lengthsspecial types on requestSelected version:Basic type: JUMO tecLine redox combination electrode, PEI plastic with protective cageActive part: Platinum domeDiaphragm: 1x glass fiberElectrical connection to electrode: screw head Pg13.5 (S8)Fitting length: 120mm (standard)Extra codes: Salt reserve, double chamber KCI/KCIOrder code: 201025/72-22-05-22-120/837, 838
Room, outdoor and duct resistance thermometers Typ: 902520/21-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/21-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/22-474-1003-1/330,(-40..80°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, 4-20 mA output (only in conjunction with 1xPt100 tw)(-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-573-1003-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-573-1005-1/000 Measuring range from -30 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/330,(-30..60°C) Measuring range from -40 to +80°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 zl) (-30 to 60°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/333,(-30..60°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 zl)(-30 to +60°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/23-474-1003-1/330,(-40..80°C) Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 tw) (-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Measuring range from -40 to +80°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 tw) (-40 to +80°C) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Conductivity measuring cell N-LF1210/PT1000 – Buy online Precise measurement for your water analysis The conductivity measuring cell N-LF1210/PT1000 is the ideal solution for precise conductivity measurements in water treatment and process applications. With a cell constant K=1.0 and integrated PT1000 temperature sensor, it offers maximum accuracy and reliability. Thanks to the 1/2'' screw-in thread and solenoid valve plug, installation is particularly easy and safe. Your advantages at a glance Wide measuring range: 0–2000 µS/cm for N-LF2000 and 0–1000 µS/cm for N-LF1000 Robust materials: Black POM housing, V4A 4571 electrodes, EPDM O-ring High load capacity: max. operating pressure 6 bar, temperature up to 60 °C Easy integration: compatible with common conductivity meters Areas of application: The N-LF1210/PT1000 is perfect for: Water treatment and drinking water monitoring Process control in industrial plants Laboratory applications and quality assurance Why buy online? Benefit from fast delivery, attractive prices and expert support. Order the N-LF1210/PT1000 conductivity measuring cell now and ensure precise measurements for your applications.
This electrode is suitable for pool, groundwater and drinking water.Platinum - for standard applications in the pool and environmental sector as well as for normal or high temperature resistanceGold - used in connection with chlorine electrolysis and for normal or high temperature resistance
This electrode is suitable for pool, groundwater and drinking water.Platinum - for standard applications in the pool and environmental sector as well as for normal or high temperature resistanceGold - used in connection with chlorine electrolysis and for normal or high temperature resistance
This electrode is suitable for pool, groundwater and drinking water.Platinum - for standard applications in the pool and environmental sector as well as for normal or high temperature resistanceGold - used in connection with chlorine electrolysis and for normal or high temperature resistance
This electrode is suitable for pool, groundwater and drinking water.Platinum - for standard applications in the pool and environmental sector as well as for normal or high temperature resistanceGold - used in connection with chlorine electrolysis and for normal or high temperature resistance