Wall-Mounted Resistance Thermometer by JUMO with Pt100 and Analog Transmitter with 0 to 10 V Output for Measuring Range -30 to +60 °C
JUMO Wall-Mounted Resistance Thermometer with Remote Protection Tube Protection Class IP65 Type: 902520/23-474-1003-1/333,(-30..60°C)
The wall-mounted resistance thermometer is suitable for HVAC temperature measurements with direct voltage output. Equipped with Pt100 in a two-wire circuit, an integrated 0 to 10 V transmitter, and a measuring range of -30 to +60 °C, this version is particularly suitable for robust wall-mounted measuring points with a separated measuring location.
This version is intended for wall-mounted measuring points where the temperature should be measured at a location slightly separated from the housing and transmitted directly as a voltage signal.
Technical Data
- Version: Wall-mounted resistance thermometer with remote protection tube
- Measuring insert: 1 x Pt100
- Circuit type: Two-wire circuit
- Transmitter: 1 x analog, output 0 to 10 V
- Measuring range: -30 to +60 °C
- Note: Measuring range only in combination with transmitter
- Protection class: IP65
Advantages and Technical Features
- remote protection tube for more targeted temperature measurement
- well suited for wall-mounted measuring points with a spatially separated measuring location
- suitable solution for building automation and HVAC applications
- no additional external signal conversion required
The remote protection tube is a clear advantage because the actual measuring point does not need to be located directly at the housing position. This allows the temperature to be measured more precisely where it is truly relevant for the application. This is especially practical for wall mounting when a small distance between the housing and the measuring location is beneficial or structurally required.
In addition, the integrated transmitter with a 0 to 10 V output provides the temperature signal directly as a voltage signal and allows further processing without additional external signal conversion. Especially in building automation and HVAC applications, this is beneficial when the system operates with 0 to 10 V inputs. The measuring range relevant for this version is -30 to +60 °C and applies in combination with the transmitter.
With protection class IP65, the housing is well protected against dust and water. This makes the version suitable for technically demanding environments where a more robust wall-mounted solution is required than standard room sensors.
Typical Applications
- Wall-mounted measuring points in HVAC applications
- Building automation
- Heating, ventilation, and air conditioning systems
- Applications with direct signal transmission to controllers or control systems
- Measuring points with a slightly remote measuring location
- Technical indoor areas and protected outdoor areas
- Applications with increased protection requirements against dust and water
Dimensions
| Height | 5 cm |
|---|---|
| Length | 15,5 cm |
| Width | 6 cm |
Weight
| Weight | 1,189 kg |
|---|
Other attributes
| Country of origin | DE |
|---|---|
| Customs tariff number | 90251900 |
| Messeinsatz | 1x Pt 100 Zweileiterschaltung |
| Messumformer | Messumformer analog Ausgang 0-10 V |
| Temperaturbereich | -40°C ... +80°C |
| Toleranz / Klasse | Klasse B |
| Feature | Description |
|---|---|
| Connection housing |
Plastic housing made of PC (basic type 902520/11, material: PP),
degree of protection IP20 to IP65. Basic type 902524/25, degree of protection IP54 and IP65. |
| Protective tube | Stainless steel 1.4571; Ø 6 mm |
| Measuring insert |
Pt100 temperature sensor, DIN EN 60751, class B, two-wire circuit. Pt1000 temperature sensor, DIN EN 60751, class B, two-wire circuit. Further versions, see ordering information. |
| Transmitter | Analogue transmitter, output signal 4 to 20 mA or 0 to 10 V. |
| Characteristic | Output 4 to 20 mA | Output 0 to 10 V |
|---|---|---|
| Input | ||
| Measuring input | Pt100 (DIN EN 60751) | Pt100 (DIN EN 60751) |
| Sensor current | ≤0,5 mA | ≤0,5 mA |
| Measuring rate | Continuous measurement, due to analogue signal path. | Continuous measurement, due to analogue signal path. |
| Measuring circuit monitoring | ||
| Underrange (measuring range underrun) | decreasing down to ≤ 3,6 mA | 0 V |
| Overrange (measuring range overrun) | rising to ≥ 22 up to < 28 mA (typically 24 mA) |
rising to ≥ 11 up to < 14 V (typically 12 V) |
| Sensor short circuit | ≤ 3,6 mA | 0 V |
| Sensor and cable break | ≥ 22 to < 28 mA (typically 24 mA) | ≥ 11 to < 14 V (typically 12 V) |
| Output | ||
| Output signal | Pulsed direct current 4 to 20 mA | DC voltage 0 to 10 V |
| Transfer behaviour | temperature-linear | temperature-linear |
| Transmission accuracy | ≤ ±0,1 % | ≤ ±0,2 % |
| Attenuation of the residual ripple of a 24 V power supply, amplitude 10 V / 50 Hz, load 470 Ω / 10 MΩ load | 37 dB | 40 dB |
| Load (Rb) | Rb = (Ub - 7,5 V) ÷ 22 mA | - |
| Load effect | ≤ ±0,02 % / 100 Ωa | - |
| Load / Load Influence | - | ≥ 10 kΩ / ≤ ±0,1 % |
| Settling time after temperature change | ≤ 10 ms | ≤ 10 ms |
| Calibration conditions | DC 24 V / approx. 22 °C | DC 24 V / approx. 22 °C |
| Calibration accuracy | ≤ ±0,2 %a,b or ≤ ±0,2 K | ≤ ±0,2 %a,b or ≤ ±0,2 K |
| Overall sensor accuracy/Calibration | ±0,4 K (typical) at 20 °C / 24 V Power supply |
±0,4 K (typical) at 20 °C / 24 V Power supply |
| Power supply | ||
| Power supply (Ub) | DC 7,5 at 30 V | DC 15 at 30 V |
| Reverse polarity protection | yes | yes |
| Power supply influence | ≤ ±0,01 %/V Deviation from 24 Va | ≤ ±0,01 %/V Deviation from 24 Va |
| Environmental influences | ||
| Operating temperature range | -40 to +85 °C | -40 to +85 °C |
| Lagertemperaturbereich | -40 to +100 °C | -40 to +100 °C |
| Temperature influence | ≤ ±0,01 %/K deviation from 22 °C a | ≤ ±0,01 %/K deviation from 22 °C a |
| Climatic resistance similar to DIN EN 60654 class C1 |
relative humidity ≤ 95% annual average without condensation | relative humidity ≤ 95% annual average without condensation |
| EMC emissions and immunity | EN 61326 class B, industrial requirements | EN 61326 class B, industrial requirements |
a All specifications refer to the full-scale value of 20 mA.
b The higher value applies.
| Certification marks | Testing body | Certificate / test number | Basis for audit | Applies to |
|---|---|---|---|---|
|
SIL QUALIFIED PL QUALIFIED |
– | – | – |
Type suffix 058 in conjunction with the manufacturer's declaration |