- Water Analyzers
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Ozone and UV technology
- Dosing technology
- Plant engineering
- Water Meters
- Accessories
- Blog
- Gas Measuring Instruments
- Hygiene and Disinfection
- Training courses
Filter products
For applications that do not require deionised water, we offer a modified version of our cabinet system that is capable of producing permeate. Unlike the deionised water treatment system, the permeate cabinet system consists of only one cabinet. Water treatment involves pre-filtration, a softening system, a reverse osmosis system with a 100-litre permeate tank including a water seal and sterile filter, and a pressure booster station. If required, a brine lifting system can also be integrated into the first cabinet. The installed components are listed again below: Cabinet Filter system (pre-filter & activated carbon filter) Water softener Reverse osmosis system Permeate tank 100 litres (volume can be adjusted) Pressure booster station Brine lifting system (optional) System performance: Depending on the system design, 90 l, 150 l, 230 l or 300 l of permeate can be produced per hour. The capacity of the permeate tank is adjustable, but may need to be positioned outside the cabinet due to its larger dimensions. Shut-off via system separator To protect the drinking water network from contamination by treated water or changes in the natural composition of the drinking water fed into the system as a result of technical treatment, the installation of a system separator is mandatory. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection. Aqua-Stop (solenoid valve shut-off) An Aqua-Stop is a safety mechanism used in water supply systems to stop or limit the flow of water in the event of a malfunction or leak. It is usually an automatic shut-off mechanism that closes the water supply valve to prevent major water damage. A solenoid valve is a type of shut-off valve that is controlled by the use of an electromagnetic field. In water treatment, a solenoid valve is used to shut off or regulate the flow of water. The solenoid valve consists of an electromagnetic coil system and a valve mechanism. Applying an electrical voltage to the coil generates a magnetic field that influences the valve mechanism. Depending on the application, the solenoid valve can be opened or closed to allow or block the flow of water. In combination, additional safety and control over the water flow can be ensured. The Aqua-Stop is located directly behind the main water connection of the system as the first element. The associated solenoid valve is coupled with two sensors, one of which continuously monitors the base trays of the two cabinet systems. Filter system The pre-filter section is a filter unit consisting of a pre-filter and an activated carbon filter. Its main purpose is to protect downstream softening and osmosis systems, which could be damaged by impurities in the water. Water softener A water softener is used to remove excess minerals, especially calcium and magnesium ions, which are responsible for the hardness of the water. It works on the basis of an ion exchange process. Reverse osmosis Reverse osmosis reverses the natural osmotic process. In this process, the softened water is forced through a membrane under pressure, whereby the membrane only allows water molecules and very small molecules to pass through and retains larger particles such as salts, bacteria, viruses and other impurities. Permeate tank A round tank offers advantages in terms of stability, cleaning, energy efficiency and space utilisation, making it the preferred choice for storing and treating water in treatment plants. Its uniform shape and flow characteristics ensure that the water is treated and stored efficiently. Pressure boosting station A pressure boosting station is used to continuously supply the connected consumers with the required operating pressure. Cabinet systems Only a minimum floor space of 0.80 m x 1.40 m is required to install this module from HeylNeomeris. The module consists of a cabinet that is 0.80 m wide and 0.60 m deep. It is possible to use double doors, which, due to the depth of 60 cm and a double door with a dimension of 40 cm, results in a minimum room depth of 1 m. The cabinets used are made of sturdy sheet steel modules and have a high-quality surface coating. Wastewater disposal via brine lifting unit (optional) As an optional component, the treatment plant can be expanded to include an integrated wastewater lifting unit, which transports the generated and collected wastewater into the sewer system. The main wastewater flows here are the wastewater from the regeneration of the softening plant and the concentrate from the reverse osmosis process. Collection tray The integrated collection tray in the cabinet serves to collect potential leaks or escaping liquids that could escape from the pipes or components. This is particularly important, for example, in industrial applications or in environments where sensitive electronic equipment or chemicals are stored.
For applications that do not require deionised water, we offer a modified version of our cabinet system that is capable of producing permeate. Unlike the deionised water treatment system, the permeate cabinet system consists of only one cabinet. Water treatment involves pre-filtration, a softening system, a reverse osmosis system with a 100-litre permeate tank including a water seal and sterile filter, and a pressure booster station. If required, a brine lifting system can also be integrated into the first cabinet. The installed components are listed again below: Cabinet Filter system (pre-filter & activated carbon filter) Water softener Reverse osmosis system Permeate tank 100 litres (volume can be adjusted) Pressure booster station Brine lifting system (optional) System performance: Depending on the system design, 90 l, 150 l, 230 l or 300 l of permeate can be produced per hour. The capacity of the permeate tank is adjustable, but may need to be positioned outside the cabinet due to its larger dimensions. Shut-off via system separator To protect the drinking water network from contamination by treated water or changes in the natural composition of the drinking water fed into the system as a result of technical treatment, the installation of a system separator is mandatory. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection. Aqua-Stop (solenoid valve shut-off) An Aqua-Stop is a safety mechanism used in water supply systems to stop or limit the flow of water in the event of a malfunction or leak. It is usually an automatic shut-off mechanism that closes the water supply valve to prevent major water damage. A solenoid valve is a type of shut-off valve that is controlled by the use of an electromagnetic field. In water treatment, a solenoid valve is used to shut off or regulate the flow of water. The solenoid valve consists of an electromagnetic coil system and a valve mechanism. Applying an electrical voltage to the coil generates a magnetic field that influences the valve mechanism. Depending on the application, the solenoid valve can be opened or closed to allow or block the flow of water. In combination, additional safety and control over the water flow can be ensured. The Aqua-Stop is located directly behind the main water connection of the system as the first element. The associated solenoid valve is coupled with two sensors, one of which continuously monitors the base trays of the two cabinet systems. Filter system The pre-filter section is a filter unit consisting of a pre-filter and an activated carbon filter. Its main purpose is to protect downstream softening and osmosis systems, which could be damaged by impurities in the water. Water softener A water softener is used to remove excess minerals, especially calcium and magnesium ions, which are responsible for the hardness of the water. It works on the basis of an ion exchange process. Reverse osmosis Reverse osmosis reverses the natural osmotic process. In this process, the softened water is forced through a membrane under pressure, whereby the membrane only allows water molecules and very small molecules to pass through and retains larger particles such as salts, bacteria, viruses and other impurities. Permeate tank A round tank offers advantages in terms of stability, cleaning, energy efficiency and space utilisation, making it the preferred choice for storing and treating water in treatment plants. Its uniform shape and flow characteristics ensure that the water is treated and stored efficiently. Pressure boosting station A pressure boosting station is used to continuously supply the connected consumers with the required operating pressure. Cabinet systems Only a minimum floor space of 0.80 m x 1.40 m is required to install this module from HeylNeomeris. The module consists of a cabinet that is 0.80 m wide and 0.60 m deep. It is possible to use double doors, which, due to the depth of 60 cm and a double door with a dimension of 40 cm, results in a minimum room depth of 1 m. The cabinets used are made of sturdy sheet steel modules and have a high-quality surface coating. Wastewater disposal via brine lifting unit (optional) As an optional component, the treatment plant can be expanded to include an integrated wastewater lifting unit, which transports the generated and collected wastewater into the sewer system. The main wastewater flows here are the wastewater from the regeneration of the softening plant and the concentrate from the reverse osmosis process. Collection tray The integrated collection tray in the cabinet serves to collect potential leaks or escaping liquids that could escape from the pipes or components. This is particularly important, for example, in industrial applications or in environments where sensitive electronic equipment or chemicals are stored.
Under-sink system– Compact Solutions for Pure Water Quality Undercounter systems are space-saving, efficient water treatment solutions designed for discreet installation beneath work surfaces. They are indispensable in sensitive environments such as medical technology, laboratory furniture, dental clinics, and the MedTec industry. These systems reliably deliver purified water – demineralized (DI) water – exactly where it's needed. Advantages of Under-sink system: Compact design for integration into furniture and workspaces Easy to incorporate into existing supply systems Reliable multi-stage water purification Hygienic dispensing options for medical applications Example from the HeylNeomeris Range: NeoPureMini – Multi-Stage Under-sink Diluat System Pre-assembled on a stable frame and ready to connect, the NeoPureMini is ideal for installation under lab benches, in dental offices, or in medical furniture modules. With multi-stage filtration (including activated carbon, fine filtration, and optional UV stage), it provides high-purity DI water for stringent hygiene requirements in the sterilization of medical instruments in outpatient centers, operating rooms, and clinics.
Our 4- or 8- channel system allows the processing of up to four or eight measurement signals. For this purpose, 4-20 mA/ RS232 as well as Modbus RTU are available as signal inputs. Based on the received data a visualization as well as a trend display takes place. Through modular addition of optional modules (slaves) the realization of popular control concepts is possible.Advantages:Simple operation Integration of the Testomat® device world Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housingModular function range expandable by NeoTec slave modules (measure, control, control)Available as installation variant or structure variant Contents: NeoTecMaster® 5 inch - 4 channel system (optionally expandable to 8 channels) with Modbus interface and RS232 input for data communicationNeoTec Slave 4-20mA module (inputs: 8x 20mA)NeoTecMaster® IP66 housing for 5" display, light grey with front foilUSB stick for NeoTecMaster® 8GBInstallation of NeoTecMaster® in housing incl. parameterisation and cabling of the NeoTecMaster®Universal power supply 24V/6A DC (100-240V AC) (144 Watt)
The housing for holding the master or display unit as well as up to 6 function modules incl. optimized cable routing for connecting the individual components & PG glands for connecting external cables (e.g. for Ethernet, sensors and measurement technology). The advantages at a glance: Increase of the protection class to IP 66 and thus protection of the components against damage by environmental conditions. Optimized access for the cabling of the connected components.
The pressure booster station with permeate storage tank for the NeoPermlon permeate cabinet system has the task of supplying the required amount of water at sufficient pressure to the connected consumers. These consumers in modern commercial kitchens include steam cookers, coffee machines and dishwashers. The pressure increase ensures that these appliances are constantly supplied with the required water, while at the same time optimising the pressure conditions to the consumption requirements.
The pressure booster station with permeate storage tank for the NeoPermlon permeate cabinet system is designed to supply connected consumers with the required amount of water at sufficient pressure. In modern commercial kitchens, these include steam cookers, coffee machines and dishwashers. The pressure increase ensures that these appliances are continuously supplied with the required water at a pressure that is tailored to the demand.
The pressure booster station with permeate storage tank for the NeoPermlon permeate cabinet system has the function of supplying the connected consumers with the required amount of water at sufficient pressure. In modern commercial kitchens, these include steam cookers, coffee machines and dishwashers. The pressure booster ensures that these appliances are supplied with the necessary water at a pressure adapted to the demand without interruption.
The pressure booster station with permeate storage tank for the NeoPermlon permeate cabinet system is designed to supply connected consumers with the required amount of water at sufficient pressure. In modern commercial kitchens, these include steam cookers, coffee machines and dishwashers. The pressure boost ensures that these appliances are supplied with water at a pressure corresponding to the demand without interruption.
Pyrogen filter A pyrogen filter is a special type of filter used in water treatment to remove pyrogens from the water. Pyrogens are substances that can cause an immunological reaction in the body, in particular an increase in body temperature. These are usually endotoxins released by bacteria such as Escherichia coli (E. coli). The pyrogen filter consists of a filter element with a very fine pore size and an associated filter housing. The pyrogen filter is available with filter elements of 0.05, 0.1 or 0.2 micrometres, which you can select as required. This enables the filter to effectively retain particles and microorganisms, including pyrogenic bacteria that may be present in the water. In the modular water treatment plant, the pyrogen filter is used after other pre-treatment stages such as filtration and disinfection. After the water has been purified of particles and microorganisms, it is passed through a pyrogen filter to remove any pyrogens. Pyrogen filters are particularly important in industries where pyrogen-free water is crucial, such as in outpatient care, to ensure the optimal quality of surgical instruments. Overall, pyrogen filters play an important role in water treatment to ensure the quality and purity of the water and minimise potential exposure to pyrogenic substances.
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 10kg per sack Type of packaging: PE film Storage description: store dry and well closed Certifications: ISO 9001, ISO 14001 and IFS Standard: The product complies with the following standards. EN 973:2009 Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A EN 16401:2013 Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A EN 14805:2022 Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1 EN 16370:2022 Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2 Purchase options: Single purchase: 1x 10kg sack (Art.-No. 896467) Pallet purchase: 100x 10kg sacks (Art.-No. 896498)
Proposed use: for the regeneration of water softeners Composition: evaporated salt (min. 99.9% NaCl) Dimensions / weight of tablet: ø25mm / 14g Moisture content: < 0.08 Filling weight: 25kg per sack Type of packaging: PE film Storage description: store dry and well closed Certifications: ISO 9001, ISO 14001 and IFS Standard: The product complies with the following standards... EN 973:2009 Products for the treatment of water intended for human consumption - Sodium chloride for regenerating ion exchange resins -Type A EN 16401:2013 Products for the treatment of swimming pool water - Sodium chloride for use in electrochemical chlorine production plants - Type A EN 14805:2022 Products for the treatment of water intended for human consumption - Sodium chloride for on-site electrochemical production of chlorine by membrane-free processes - Type 1 EN 16370:2022 Products for the treatment of water intended for human consumption - Sodium chloride for the on-site electrochemical production of chlorine by means of membrane cells - Quality 2 Purchase options: Single purchase: 1x 25kg sack (Art.-No. 896468) Pallet purchase: 40x 25kg sacks - 1000 kg (Art.-No. 896500)
Testomat 808: Continuous Hardness Limit Monitoring Online measurement of residual water hardness with automatic color change Measurement Principle and Technical Features Modern indicator pump system supporting an automated process with minimal reagent and water consumption. Internal and external flushing options, manual safety check for up to 72 hours of unattended operation (BOB operation), and interfaces for 4–20 mA signals and RS232 firmware updates. Purchase Benefits 3% shop discount when purchasing a Testomat 808 Free of charge: original Heyl indicator for hardness measurement
The Testomat® 808 is a compact analyser for online measurement of water hardness according to the principle of "limit value monitoring with colour change" in the measuring range 0.02 - 5 ° dH (0.4 - 89 ppm). Applications of the continuous residual hardness monitoring are e.g.: Reverse osmosis systems, boiler feed water supply Soft water for commercial purposes, ultrapure water systems. In view of the fact that the Testomat® 808 is suitable for use in multi-parameter systems due to its 4-20mA signal output, we hereby offer you the Testomat® 808 in conjunction with the NeoTecMaster® Multicontroller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® Multicontroller included in this package enables the processing of up to four measurement signals. Via the 4-20mA NeoTec slave input module connected to the NeoTecMaster®, the data is transmitted to the NeoTecMaster® and used to display the measured value, the trend and the status messages on the 5-inch screen. In addition, the NeoTecMaster® has an RS232 interface as well as a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required. This allows the future realisation of further control concepts in a flexible way. Two modules which fundamentally extend the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA input module. This allows you to add potential-free relay contacts to the overall system and to integrate and visualise further system technology such as sensors via the 4x 4-20mA input module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, implement simple limit value-related control concepts as well as output measurement value-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® device world, here in connection with the Testomat® 808 Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® enclosure Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation) Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are the proven functionalities of the Testomat® 808: Indication of limit value undershoot or overshoot: green / red LED Modern indicator pump system Automatic measuring sequence with low water consumption Direct error and indicator quantity display Internal and external flushing of the measuring chamber by manual control Control of an external flush valve Three potential-free relays for: External flush valve control Limit value evaluation External control and / or alarm processing Safety check for 72-hour operation without supervision Indicator quantities: 100 and 500 ml bottles 4 - 20 mA interface for defined status and error messages RS 232 interface for firmware updates General information Water connection and operating pressure: Depending on unit version: 0.3 - 1 bar / 0.3 x 105 to 4 x 105 Pa 1 - 4 bar / 1 x 105 to 4 x 105 Pa (from 4 to 8 bar, a pressure reducer must be used (special accessory)) Water inlet: opaque hose with 6 mm outer diameter/4 mm inner diameter Water outlet: hose with 6 mm outer diameter/4 mm inner diameter Water temperature: 10 to 40 °C From 4 bar, a separately available pressure reducer must be used. Please use only the indicators approved for Testomat® 808! Optional accessories: NeoTecMaster unit hood
Precise Water Hardness Analysis for Automated Process and System Monitoring with the Testomat EVO TH Fully automatic water hardness determination via titration The Testomat EVO automatically detects the water level when filling the measuring chamber and can also operate for extended periods in BOB mode without constant supervision. With an integrated SD card or optionally an SDHC card (2 GB), measurement data and messages/alarms can be recorded. The menu is available in multiple languages, and firmware updates can be conveniently applied via the SD card. Analog outputs and serial interfaces allow external processing of measurement data. Certified and Cost-Effective Standalone Water Hardness Meter With the Testomat EVO, you benefit from stable, low-maintenance continuous operation, minimal consumption of indicator solution and water, as well as versatile data communication via RS232 or 0/4–20 mA signals. Certification according to relevant safety and TÜV standards (WÜH certification for boiler houses) and the compact design make the EVO a robust and efficient solution for demanding measurement tasks. Applications for the Testomat EVO Water treatment Drinking water systems Industrial boilers Process water monitoring When purchasing the Testomat EVO online, you receive, in addition to a 3 % online discount on Heyl devices, a free indicator of your choice.