Go to homepage
Wishlist
Account
Login
New customer registration Existing customer registration
Overview Your profile Addresses Payment methods Orders Subscriptions Warranties Videos
€0.00*
Home
Water Analyzers
Liquid chemistry
Controls
Electrodes and sensors
Gas Measuring Instruments
Analysis Suitcases
Hygiene and Disinfection
NeoTec World
Blog
Seminars & Webinars
Ozone and UV technology
Dosing pumps
Devices
TESTOMAT 2000®
Water hardness / carbonate hardness / minus m - value / p - value
Bromine
Free Chlorine
Total Chlorine
Chlorine dioxide
Chromate & Chrome VI
Iron-II and Iron-III
Sulphite
Ortho - Phosphate
Polymers / Polyacrylates
TESTOMAT® ECO/EVO
Water hardness
Carbonate hardness
TESTOMAT® 808
Water hardness
Silicate
TESTOMAT® LAB
Total chlorine / Free chlorine
Water hardness
Monochloramine
TITROMAT®
Total hardness
m-value
Carbonate hardness
Softwater RS
Parameters
Water hardness  (Ca2+ and Mg2+)
Total hardness (TH)
Carbonate hardness (KH)
Acid capacity (pH 4,3; KS 4,3) and p- Wert (pH 8,2; KS 8,2)
Base capacity (KB82)
Bromine (Br)
Free Chlorine (HOCl)
Total chlorine (CC)
Chlorine dioxide (ClO2)
Chromate & Chromium Cr(VI)
Iron (II + III dissolved - Fe3O4)
Sulphite (SO32)
Silicate (SiO2 - dissolved)
Ortho-Phosphat (P2O5)
Polymere & Polyacrylate
Monochloramine (NH2CL)
TESTOMAT® - Accessories
Accessories for installation
Coolers
Cards
Spare Parts
TESTOMAT 2000 / ECO / EVO / TITROMAT - Spare Parts
TESTOMAT 808 / 808 SiO2 - Spare Parts
Testbestecke
Softwater RS
Service sets and maintenance cases
TESTOMAT 2000 / ECO / EVO / TITROMAT - Service sets and maintenance cases
Testomat 808 / 808 SiO2 - Service sets and maintenance case
Show all Liquid chemistry
Indicators / Reagents
TESTOMAT® - Indicators
100 ml bottle
500 ml bottle
Testomat 2000 Reagents
Testomat Special-Solution
Titromat Reagents
Testomat 808 / F-BOB Indicators
100 ml bottle
500 ml bottle
Testomat 808 SIO2 Reagents
100 ml bottle
500 ml bottle
Testomat C-BOB Indicators
100 ml bottle
500 ml bottle
Testomat M-BOB Indicators
100 ml bottle
500 ml bottle
Testomat LAB Reagents
pH / ORP Buffer and Conductivity Calibration Solutions
pH buffer solution
ORP buffer solution
Conductivity calibration solution
Storage solution (KCL electrolyte)
Cleaning solution pH / ORP electrodes
Test Kits
Product Group
DUROVAL® Titration Test Kits
TESTOVAL® Colorimetric Test Kits
DUROGNOST® Limit Value Test Kits
Polyamine Test Kits
Parameters
Water Hardness (Ca2+ und Mg2+)
Carbonate hardness (KH)
m-value (total alkalinity - acid capacity up to pH 4.3; KS 4.3)
p-value (acid capacity up to pH 8.2; KS 8.2)
Base capacity (KB82 - to pH 8.2)
Aluminium (Al)
Ammonia (NH4+)
Chlorine (Cl DPD methode)
Chloride (Cl-)
Chromate Cr(VI)
Iron (II + III dissolved- Fe3O4)
Hydrazine (N2H4)
Carbon dioxide (CO2)
Copper (Cu)
Cooling lubricants (KSS)
Nitrite (NO2)
pH
Phosphate (P2O5 - Ortho-Phosphate)
Polyamines (PA - circuit water)
Silicate (SiO2 - dissolved)
Sulphate (SO4)
Sulphite (SO32)
Analysis Cases and Analysis Cabinets
Multiparameter Handheld Photometer
Accessories
Devices
Softmaster
Neomeris Control
NeoTecMaster®
SOFTMASTER AND MULTICONTROL ACCESSORIES
Show all Electrodes and sensors
Hand-held measuring instruments in a carrying case
pH / ORP / Temp.
pH / Conductivity / ORP/ Temp.
Conductivity / TDS / Temp.
Oxygen / Saturation / Pressure / Temp.
Pocket Testers
Pocket-Tester
Spare electrodes
Select pH / ORP / conductivity electrodes
ORP
Conductivity
pH
Conductivity measuring instr.
Devices
Conductivity cells
Accessories
Sampling cooler
Cooler
Valves
Pool and laboratory electrodes
pH
ORP
Accessoires
Show all Gas Measuring Instruments
Ozone
Hydrogen peroxide
Phosphine
Show all Hygiene and Disinfection
cleaneroo
HyMo-Box
Show all NeoTec World
NeoTecMaster®
NeoTec Slaves
NeoTec Signal converter
NeoTec Select Sensors
NeoTec Accessories
Show all Seminars & Webinars
Product training Testomat®
Processing of sterile goods
Show all Ozone and UV technology
Catalytic residual ozone destructors
Ozone generators
UV systems
Pharma
Show all Dosing pumps
Pumps
Spare parts and accessories
Show all categories Free Chlorine Back
  • Show Free Chlorine
  1. Water Analyzers
  2. Devices
  3. TESTOMAT 2000®
  4. Free Chlorine
  • Water Analyzers
    • Devices
      • TESTOMAT 2000®
        • Water hardness / carbonate hardness / minus m - value / p - value
        • Bromine
        • Free Chlorine
        • Total Chlorine
        • Chlorine dioxide
        • Chromate & Chrome VI
        • Iron-II and Iron-III
        • Sulphite
        • Ortho - Phosphate
        • Polymers / Polyacrylates
      • TESTOMAT® ECO/EVO
      • TESTOMAT® 808
      • TESTOMAT® LAB
      • TITROMAT®
      • Softwater RS
    • Parameters
    • TESTOMAT® - Accessories
    • Spare Parts
    • Service sets and maintenance cases
  • Liquid chemistry
  • Controls
  • Electrodes and sensors
  • Gas Measuring Instruments
  • Analysis Suitcases
  • Hygiene and Disinfection
  • NeoTec World
  • Blog
  • Seminars & Webinars
  • Ozone and UV technology
  • Dosing pumps
Filter
–
Testomat 2000® CLF
Testomat 2000® CLF
Product number: 100240
Language in the display: German | Performance/execution: 230 V/50-60 HZ
The Testomat 2000® CLF process photometer is an online analyzer for monitoring the ontent of free chlorine (CLF) in the range of 0-2.5 mg / L (ppm).Performance profile: Analysis via automatic dosing of two reagents The analysis result is displayed after a reaction time of approx. 1 min. (Measuring time without rinsing time)2 independently programmable limit contacts for monitoring and control tasks Menu-driven operation and programming via plain text display High-precision titration using a piston dosing pump [#dspacer#][#dspacer#][#dspacer#]Analysis initiation: Automatic interval operation (Interval pause adjustable from 0–99 min) External control Dynamic (fatigue-dependent interval operation) Quantity dependent via contact water meter Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functionsMonitoring of two measuring points (Switching by external solenoid valves)programmable service address Internal error documentation Programmable maintenance interval for maintenance request

€6,837.50*
Details
Tip
Testomat® EVO TH + LAB CL with NeoTecMaster® - value-added package
Testomat® EVO TH + LAB CL with NeoTecMaster® - value-added package
Product number: 851065
The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. On top of that our Testomat® EVO TH is approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.  It is supplemented by the Testomat® LAB CL, a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® EVO TH and the Testomat® LAB CL in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® EVO TH and  Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® EVO TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® functionalities of both devices: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® EVO TH: High-precision titration by means of piston metering pump LCD graphic displayMultilingual menu with easy switching (internal programming is retained)External clear / acknowledge inputFree programmable passwordRange monitoring (fall below limit value1 / exceed limit value 2)Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 100 and 500 ml bottles Analysis trigger:automatic interval operation (0-99 minutes)depending on quantity via contact water meter Performance profil Testomat® LAB CL: High-precision peristaltic pumpsReliable and low-maintenance operationMinimal reagent and water consumptionAnalog output 4 - 20 mA for transmission of measured valuesRS232 interface for transmission of measured values & fault messagesExecution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch Compact design Common alarm outputOptimised reagents: Only 2 reagents for the determination of total chlorineOptimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same timeAnalysis triggering:Automatic interval operation (interval pause adjustable from 10-60 minutes)Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand startOptional accessories available: OLED display for Testomat® LABProtective cover to increase the IP protection class of the Testomat® LABNeoTecMaster instrument cover

€7,332.15*
Details
Tip
Testomat® LAB CL with NeoTecMaster® - value-added package
Testomat® LAB CL with NeoTecMaster® - value-added package
Product number: 851067
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB CL in combination with the NeoTecMaster® Multi Channel Controller, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input, in this case the RS232 interface, is used by the Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. Two modules that fundamentally expand the range of functions and are already included in the scope of delivery are our NeoTec slave relay module and the 4x 4-20mA output module. This allows you to add potential-free relay contacts to the overall system and to realise linear or inverted dosing processes via the 4x 4-20mA output module. You can freely assign the relay contacts to the incoming measurement signals and thus, for example, also implement simple limit value-related control concepts, as well as output measurement value-related messages. Via the 4-20mA output module, you can also forward the measured values to a higher-level controller as desired. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format  In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Integrated self-test with continuous monitoring Automatic venting of the indicator line Performance profil Testomat® LAB CL: High-precision peristaltic pumpsReliable and low-maintenance operationMinimal reagent and water consumptionAnalog output 4 - 20 mA for transmission of measured valuesRS232 interface for transmission of measured values & fault messagesExecution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch Compact design Common alarm outputOptimised reagents: Only 2 reagents for the determination of total chlorineOptimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same timeAnalysis triggering:Automatic interval operation (interval pause adjustable from 10-60 minutes)Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand startOptional accessories available: OLED display for Testomat® LABProtective cover to increase the IP protection class of the Testomat® LABNeoTecMaster instrument cover

€4,584.70*
Details
Tip
Testomat® LAB TH + LAB CL with NeoTecMaster® - value-added package
Testomat® LAB TH + LAB CL with NeoTecMaster® - value-added package
Product number: 851064
The Testomat® LAB TH determines the water hardness (residual total hardness) fully automatically by use of titration and has been developed for monitoring the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water and the Testomat® LAB CL is a robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time). In view of the fact that the Testomat® LAB TH and Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you both Testomat® LAB analysis devices in combination with the NeoTecMaster®, which was specially developed by our company, as a package solution at a preferential price. The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input on the NeoTecMaster® , in this case the RS232 interface and one additional RS232 interface on the included NeoTec Slave module , are used by Testomat® LAB TH and  Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexible manner. A module that fundamentally expands the range of functions and is already included in the scope of delivery is our NeoTec slave relay module with which you can add potential-free relay contacts to the overall system. You can freely assign these to the incoming measurement signals and thus, for example, implement limit value-related control concepts, as well as output measurement-related messages. Further advantages of the NeoTecMaster: Simple operation Integration of the Testomat® world of instruments, here in conjunction with the Testomat® LAB TH and Testomat® LAB CL Integration into the existing control cabinet, alternatively we offer our NeoTecMaster® housing Modular range of functions can be extended by NeoTec slave and signal converter modules (measurement, control, regulation)Available as built-in or surface-mounted variant Structured continuous data recording on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format In addition, there are proven Testomat® LAB functionalities: Optimised water detection based on an optical measuring method RS232 interface for transmission of measured values and error messages Import and export of settings (basic programming) Logging of measurement data and messages/alarms via integrated SD card or optionally usable SDHC card (2GByte) Firmware update via SD card Execution of parameterisation by means of SD card or "Service Monitor" software via mini-USB (on the unit side) to USB 2.0 (e.g. PC/notebook) Multilingual software menu in German, English, French, Dutch Integrated self-test with continuous monitoring Automatic venting of the indicator line Compact design Performance profil Testomat® LAB TH: High-precision titration by means of piston metering pump Reliable and low-maintenance operation Minimal indicator and water consumption Analogue output 4 - 20 mA for transmission of measured values Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l Collective alarm output Indicator quantities: 500 ml bottles Analysis trigger:                  - Automatic interval operation (interval pause adjustable from 0-255 minutes)                  - External analysis input (start/stop)                  - Manual start  Performance profil Testomat® LAB CL: High-precision peristaltic pumpsReliable and low-maintenance operationMinimal reagent and water consumptionAnalog output 4 - 20 mA for transmission of measured valuesRS232 interface for transmission of measured values & fault messagesCommon alarm outputOptimised reagents: Only 2 reagents for the determination of total chlorineOptimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same timeAnalysis triggering:Automatic interval operation (interval pause adjustable from 10-60 minutes)Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours) External analysis input (start/stop) Hand startOptional accessories available: OLED display Protective cover to increase the IP protection class of the Testomat® LAB devices NeoTecMaster instrument cover

€6,654.35*
Details
Contact

Gebr. Heyl Vertriebsgesellschaft
für innovative Wasseraufbereitung mbH


Max-Planck-Str. 16, D-31135 Hildesheim
P.O. Box 100518, D-31105 Hildesheim
Telephone: +49 (0) 5121 7609-0
Fax: +49 (0) 5121 7609-44
E-Mail: vertrieb@heylneomeris.de

Website: https://www.neomeris.de
Shop: https://www.heylneomeris.shop
AG Hildesheim - HRB-No. 3673
Managing director: Marc Osterwald

VAT-ID DE 146891113
WEEE-Reg.-No. DE 30201093
Batt-Reg.-No. DE 96440121

Or via our contact form.
Company
  • About us
  • Heyl Neomeris Website
Service / Help
  • Indicator & reagent subscription
  • Indicator consumption calculator
  • Reagent consumption calculator
  • Device warranty registration
  • Downloads and Safety Data Sheets
  • Terms of service
  • Privacy
  • Right of rescission
  • Payment / Shipping
  • Imprint
Certifications / partnerships


PayPal
Credit or debit card
SEPA direct debit
Bancontact
BLIK
eps
Giropay
iDEAL
Multibanco
MyBank
Przelewy24
Sofort
Bank transfer, pre-payment
Pay Later
  • Indicator & reagent subscription
  • Indicator consumption calculator
  • Reagent consumption calculator
  • Device warranty registration
  • Downloads and Safety Data Sheets
  • Terms of service
  • Privacy
  • Right of rescission
  • Payment / Shipping
  • Imprint

* All prices excl. VAT plus shipping costs and possible delivery charges, if not stated otherwise.

Realisierung durch XICTRON Internetagentur.
This website uses cookies to ensure the best experience possible. More information...