Testomat 2000® CLF

Product number: 100242

€7,113.90*

Please log in to receive your conditions.

Available in 140 days, delivery time 1-2 days

Language in the display
Performance/execution

Product number: 100242
GTIN: 4068823003574
Measurement parameters: Free chlorine
Measuring range: 0.00 – 0.99 mg/l (Resolution: 0.01 mg/l) 1 – 2.5 mg/l (Resolution: 0.1 mg/l)
Application: Chlorination monitoring for drinking-water or swimming pools. | Provides protection for reverse osmosis membranes. | Control of chlorine biocides and conditioning agents.
Menu navigation: German, English, French
Would you like to register the warranty for this product?
Register warranty here
A warranty extension is possible after taking out an indicator subscription.
Order the appropriate original indicator for your TESTOMAT® device:
Testomat 2000® Reagent CL2250A 500 ml Order · Subscription
Testomat 2000® Reagenz CL 2250 B 500 ml Order · Subscription
Testomat 2000® chlorine reagent set F (free chlorine) 2 x 500 ml, 1 x 400 ml Order · Subscription
Testomat 2000® chlorine reagent set F 50% (free chlorine) 1 x 500 ml A , 1 x 200 ml B Order · Subscription
Determine the appropriate reagent here: Reagent consumption calculator
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.

Leasing Example

148,61 € non-binding
Monthly Rate (60 Rates)
Prices excl. VAT

Further rate options by choosing the payment method Leasing

Alternatives to this product

Testomat® LAB CL
Product number: 116106
Pro's
  • Messbereich 0 – 5 mg/l (T2000 hat nur 0 – 2,5 mg/l)
  • Integrierte Datenaufzeichnung (Messwerte sowie Fehlermeldungen) auf SD-Karte
  • Messfunktion als dauerhaft in festen Zeitintervallen oder Messphase*2 programmierbar
Was kann es nicht?
  • Grenzwertrelais
  • Keine Displayanzeige
  • Keine 2 Messstellen
  • Kein AUX Relais
Erforderlicher Leistungsumfang
  • Analyse für freies Chlor oder
  • Gesamtchlor (Festlegung durch
  • gewählten Reagenzsatz)
  • IST-Wert Bestimmung
  • 4-20mA Messwertübertragung
  • Grenzwertrelais
    (nur umsetzbar mittels NeoTecMaster®)
Ergänzende Funktionen
  • Displayanzeige für Messwerte
  • Schutzhaube für IP 65
  • Externe Analysenauslösung (START/STOP-Relais)
  • Parametrierung mittels PC-Software
*2 Nur während dieser Zeit werden Analysen im eingestellten Intervall durchgeführt. Außerhalb der Messphase wartet das Gerät auf ein Startsignal und gibt einen Strom von 4 mA aus. Es können Werte im Bereich von 10 Minuten bis 12 Stunden eingeben werden.

€5,150.80*
Tip
Testomat® LAB CL with NeoTecMaster® - value-added package
Product number: 851067
The Testomat® LAB CL is a robust wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process. Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).

In view of the fact that the Testomat® LAB CL was developed for use in multi-parameter systems or for connection to a higher-level control system, we hereby offer you the Testomat® LAB CL in combination with the NeoTecMaster® Multi Channel Controller, which was specially developed by our company, as a package solution at a preferential price. 

The 4-channel NeoTecMaster® multi-parameter controller included in this package enables the processing of up to four measurement signals in this version. A signal input, in this case the RS232 interface, is used by the Testomat® LAB CL to display the measured value, the trend and the status messages on the 5 inch screen. 

In addition to the on board RS232 interface, the NeoTecMaster® also has a Modbus RTU input, which you can use freely after brief technical consultation with us. (Pre-check whether your existing measurement technology to be integrated requires adjustments). 

The NeoTecMaster® can be systematically supplemented with further optional NeoTec modules (function / signal converter modules) as required, thus enabling the future realisation of further control concepts in a flexib ...

€5,298.77*
Product information "Testomat 2000® CLF"
The Testomat 2000® CLF process photometer is an online analyzer for monitoring the
 ontent of free chlorine (CLF) in the range of 0-2.5 mg / L (ppm).

Performance profile:
  • Analysis via automatic dosing of two reagents
  • The analysis result is displayed after a reaction time of approx. 1 min. (Measuring time without rinsing time)
  • 2 independently programmable limit contacts for monitoring and control tasks
  • Menu-driven operation and programming via plain text display
  • High-precision titration using a piston dosing pump
  • Analysis initiation:
    • Automatic interval operation
    • (Interval pause adjustable from 0–99 min)
    • External control
    • Dynamic (fatigue-dependent interval operation)
    • Quantity dependent via contact water meter
  • Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functions
  • Monitoring of two measuring points (Switching by external solenoid valves)
  • programmable service address
  • Internal error documentation
  • Programmable maintenance interval for maintenance request

Dimensions

Height 29 cm
Length 56 cm
Width 44 cm

Weight

Weight 10,5 kg

Other attributes

Country of origin EU
Customs tariff number 90278990
Technical specifications
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–45 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 0,3–8 bar
Weight: approx. 9,5 kg
Menu Language: German, English, French
Measuring range: Free chlorine: 0.00 – 0.99 mg/l (Resolution: 0.01 mg/l) 1 – 2.5 mg/l (Resolution: 0.1 mg/l)

We recommend the following reagents and accessories

Testomat 2000® chlorine reagent set F (free chlorine) 2 x 500 ml, 1 x 400 ml
Product number: 156233
Reagent A - 2 x 500 ml  (CL2250A)Reagent B - 1 x 400 ml (CL2250B)(the reagent sets are designed for a uniform consumption of the reagents. Therefore, the capacities of the single reagent bottles are not equal)

€272.80*
Testomat 2000® chlorine reagent set F 50% (free chlorine) 1 x 500 ml A , 1 x 200 ml B
Product number: 156236
Reagent A - 1 x 500 ml (CL2250A)Reagent B - 1 x 200 ml (CL2250B)(the reagent sets are designed for a uniform consumption of the reagents. Therefore, the capacities of the single reagent bottles are not equal)

€185.60*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€134.60*
Testomat 2000® Reagent CL2250A 500 ml
Product number: 156230
500 ml-bottles of original Testomat 2000® reagent CL 2250 A can be used immediately in the Testomat 2000®® CLF or CLT.    

€104.00*
Testomat 2000® Reagenz CL 2250 B 500 ml
Product number: 156231
500 ml-bottles of original Testomat 2000® reagent CL 2250 B can be used immediately in the Testomat 2000® CLF or CLT.    

€202.40*
Current Interface SK 910
Product number: 270305
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments.   Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation   Usable in following devices: Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3,  Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2  

€257.10*