HORIBA Sodium Chloride (NaCl) Replacement Electrodes – Restore Reliable Salt Measurements
When salt content can no longer be clearly evaluated – reorder your Horiba replacement electrode online now
Sodium chloride is a central component of dissolved salts and influences many physical and technical properties of water. When measurement values no longer match the actual condition, evaluating the system becomes difficult.
In many cases, the cause lies in the electrode, which loses accuracy due to use or deposits. Replacement restores the correct detection of salt content.
Reliable basis for stable system evaluations
The measurement of NaCl serves as an important basis for assessing concentrations and loads within the medium. To ensure reliable evaluation, the electrode must provide stable and reproducible values.
How can replacement needs be identified?
-
Unclear overall evaluation of salt content
Measurement values no longer allow a clear statement about the actual concentration and make interpretation more difficult. -
Deviations in comparable samples
Similar samples deliver different results and reduce comparability. -
Influence of deposits on measurement
Residues alter measurement behavior and lead to distorted results.
Typical application areas
- Monitoring salt concentrations in water and process media
- Use in water treatment and industry
- Control of cooling and process water
- Laboratory and on-site measurements
Your advantages
- Reliable restoration of precise measurement values
- Stable results for technical applications
- Easy integration into existing systems
Ensure that your salt measurements are reliable again and keep the composition of your media under control at all times.
Filter products
The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for fast and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, regular monitoring of the sensors and, if necessary, replacement with spare sensors is crucial. These replacement sensors are tailor-made for the HORIBA LAQUAtwin series and cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is designed to maximize user-friendliness and accuracy, which HORIBA is renowned for in water quality testing worldwide. HORIBA replacement sensors guarantee users that their devices consistently deliver optimal performance and precise measurements. Advantages of HORIBA Replacement Sensors Easy Replacement: Sensors can be exchanged quickly, allowing uninterrupted measurement. High Accuracy: Replacement sensors ensure precise and reliable results. Wide Measurement Range: Various sensor types are available to capture a broad spectrum of water quality parameters. Durability: Sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions Follow these steps to replace the sensor and maintain the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester: Removing the Sensor Turn off the tester. Lift the sensor tip slightly and pull the sensor away from the device. Completely detach the sensor from the tester. Installing the Sensor Make sure the tester is turned off. Ensure the waterproof gasket is intact and clean. Attach the sensor to the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurements. This typically includes calibration and, if necessary, conditioning. How can I tell if my sensor is worn out? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, the sensor should be replaced. Regular checks and timely replacement of sensors ensure the high quality and reliability of your water quality measurements with HORIBA LAQUAtwin Pocket Testers. Please note: The salt exchange sensors, both old and new, are not compatible with each other. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for older models. Manufacturer Part Nr. 3200459866
The HORIBA LAQUAtwin Pocket Testers provide a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure that these measurements remain reliable and accurate, it is important to regularly check the sensors and replace them with spare sensors if necessary. The replacement sensors developed for the HORIBA LAQUAtwin series cover various types for different measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. All of these sensors are designed to maximize user-friendliness and precision, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and accurate measurements. Advantages of HORIBA Replacement Sensors Easy Replacement: Sensors can be quickly exchanged, allowing measurements to continue without delay. High Precision: Replacement sensors ensure that results are exact and reliable. Wide Measurement Range: Various sensor types are available to capture a broad spectrum of water quality parameters. Durability: Sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, please follow these instructions when replacing a sensor: Removing the Sensor Turn off the tester. Carefully detach the sensor from the device and lift the sensor tip. Completely separate the sensor from the tester so that the two components are no longer connected. Installing the Sensor Ensure the tester is turned off. Check that the waterproof gasket is clean and undamaged. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, it is essential to follow the steps in the user manual of the respective tester to make the device ready for accurate measurements. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, replacing the sensor is recommended. Regular checks and timely replacement of sensors are essential to ensure the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. Please note: The salt exchange sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell whether you have an older or a newer device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part Nr. 3200597237