HORIBA Sodium Ion Standard Solutions (Na⁺) – Reference Solutions for Precise Sodium Measurements
Buy Sodium Ion Standard Solutions Online – Precise Calibration for Accurate Na⁺ Measurements
Reliable adjustment of measurement systems with Horiba calibration solutions
In this category, you will find sodium ion standard solutions from HORIBA for the calibration and verification of measuring devices for Na⁺. These solutions contain precisely defined concentrations and serve as references for reliable determination of sodium ions in water.
Reliable Measurement Results for Water Treatment and Analysis
Na⁺ standard solutions support precise adjustment of measurement systems and help detect deviations at an early stage. Especially in water treatment applications, sodium levels provide important insights into processes such as ion exchange or softening.
The solutions are easy to use and allow quick verification of measuring devices both in the laboratory and directly in the field.
Why Are Sodium Standard Solutions Important?
-
Control of treatment processes
Sodium often occurs in connection with softening systems.
Measurement shows whether processes are functioning correctly.
-
Evaluation of salt balance
Sodium content influences the composition of water.
It provides important information for technical and analytical applications.
-
Ensuring precise measurement results
Deviations can lead to incorrect evaluations.
Standard solutions help reliably adjust measuring devices.
Typical Applications
- Calibration and verification of Na⁺ measuring devices
- Use in water treatment and process monitoring
- Control of ion exchange and softening processes
- Laboratory and on-site measurements
Your Added Value at HeylNeomeris Shop
- Reference solutions for targeted calibration of sodium measurement systems
- Support in evaluating treatment processes
- Quick verification of measuring devices during operation
- Suitable for precise analysis in technical applications
Benefit from specialized reference solutions and ensure the accuracy of your sodium measurements in every application.
- Measuring instruments
-
Chemistry
- Indicators
- Reagents
-
pH / ORP Buffer and Conductivity Calibration Solutions
- Hanna
-
Horiba
- pH
- ORP
- Conductivity + TDS calibration solutions
- Storage solutions (KCL)
- Cleaning solutions
- NaCl Standard Solution
- Ammonium Ion Standard Solution (NH3)
- Calcium Ion Standard Solution (Ca2+)
- Chloride Ion Standard Solution (Cl-)
- Fluoride Ion Standard Solution (F-)
- Sodium Ion Standard Solution (Na+)
- Nitrate Ion Standard Solution (NO3-)
- Potassium Ion Standard Solution (K+)
- Ammonium (NH4+)
- Sodium chloride (NaCl)
- Neomeris
- Milwaukee
- XS Instruments
- Test Kits
- Multiparameter Handheld Photometer
- Silver resin
- spare parts
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457724
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200457723
Manufacturer article number: 3200987465 (500-NA-ISA)