HORIBA Sodium Chloride (NaCl) Standard Solutions – Reference Values for Precise Salt Analysis
Targeted Testing of Salt Concentrations and Adjustment of Measurement Systems
In this category, you will find sodium chloride standard solutions from HORIBA for the verification and calibration of measuring devices for salt content and salt-related parameters. These solutions contain precisely defined NaCl concentrations and serve as references for the reliable evaluation of measurement values.
Reliable Measurement Results for Conductivity and Salt Systems
NaCl standard solutions support the precise adjustment of measurement systems and help detect deviations at an early stage. Since sodium chloride significantly contributes to the conductivity of water, the measured values provide important information about the composition and concentration of dissolved substances.
The solutions are easy to use and allow quick verification of measuring devices – both in the laboratory and directly in the field.
Why Are NaCl Standard Solutions Important?
-
Reference for salt content and concentration
The solutions contain precisely defined NaCl values.
They serve as the basis for evaluating salt systems.
-
Relationship with conductivity
NaCl directly influences electrical conductivity.
The measurement provides important insights into overall salt load.
-
Ensuring precise measurement results
Deviations can distort analysis results.
Standard solutions ensure reliable calibration.
Typical Applications
- Calibration and verification of salt and conductivity measuring devices
- Use in water treatment and process monitoring
- Control of salt concentrations in technical applications
- Laboratory and on-site measurements
Your Added Value
- Reference solutions for targeted calibration of NaCl-based measurement systems
- Support in evaluating salt content and conductivity
- Quick verification of measuring devices during operation
- Suitable for precise analysis in technical and analytical applications
Benefit from specialized reference solutions and ensure the accuracy of your salt analysis in every application.
- Measuring instruments
-
Chemistry
- Indicators
- Reagents
-
pH / ORP Buffer and Conductivity Calibration Solutions
- Hanna
-
Horiba
- pH
- ORP
- Conductivity + TDS calibration solutions
- Storage solutions (KCL)
- Cleaning solutions
- NaCl Standard Solution
- Ammonium Ion Standard Solution (NH3)
- Calcium Ion Standard Solution (Ca2+)
- Chloride Ion Standard Solution (Cl-)
- Fluoride Ion Standard Solution (F-)
- Sodium Ion Standard Solution (Na+)
- Nitrate Ion Standard Solution (NO3-)
- Potassium Ion Standard Solution (K+)
- Ammonium (NH4+)
- Sodium chloride (NaCl)
- Neomeris
- Milwaukee
- XS Instruments
- Test Kits
- Multiparameter Handheld Photometer
- Silver resin
- spare parts
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No. 3999960112
To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No. 3999960113