Temperature is a fundamental physical parameter that influences nearly all chemical, biological, and physical processes in aqueous systems. It directly affects the solubility of gases (such as oxygen), the speed of chemical reactions, and the activity and growth of biological organisms.
In water analysis, temperature is often measured alongside other parameters because it significantly impacts values such as pH, conductivity, and dissolved oxygen. Accurate temperature measurement is therefore essential for precise monitoring and control of a wide range of processes.
JUMO temperature sensors are used in numerous applications, including:
-
Drinking and wastewater treatment: Monitoring temperature to optimize precipitation, disinfection, and clarification processes.
-
Food and beverage industry: Temperature control during CIP processes, pasteurization, and product flow.
-
Pharmaceutical industry: Maintaining temperature-critical production steps and hygiene standards.
-
Aquaculture and fish farming: Ensuring appropriate water temperatures for various species.
-
Heating and cooling circuits: Controlling process heat and improving energy efficiency.
Other fields of application include:
-
Biotechnology and fermentation
-
Environmental monitoring and field measurements
-
Power plants and heat exchanger systems
-
Hydroponics and greenhouse climate control
-
Swimming pools and wellness facilities
- Water Analyzers
- Liquid chemistry
- Controls
- Electrodes and sensors
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
Push-in resistance thermometer in water vapour-tight design, pressure-tight up to 5.0 barType: 902830/30-302-2011-2-4,5-50-11-2500/000 Measuring range -70 to +200°C Connection cable: FEP 2 x Pt 100 in four-wire circuit Single resistance thermometer Tolerance class A according to DIN EN 60 751 Thermowell diameter: 4.5mm with 2 measuring circuits in four-wire circuit Installation length: 50 mm Connection cable end: Wire end ferrules according to DIN 46 228 Connection cable length: 2500 mm (standard) Extra codes: without extra codeThe plug-in resistance thermometer in water vapour-tight design is preferably used for temperature measurements in sterilisers. The specific design makes it suitable for use in atmospheres containing water vapour and under pressure. Another area of application is in apparatus engineering and laboratory technology. The thermometer can be supplied with a PTFE connection cable, which enables operation in humid rooms in the temperature range from -50 to +150 °C, or alternatively an FEP connection cable is available, which covers temperatures from -70 to +200 °C.The transition of the connection cable is strain-relieved to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class A in a two-wire circuit. In addition, the connection can optionally be made in three- and four-wire circuits to meet individual requirements.
Type: 902150/40-397-1003-1-6-60-11-2500/317 Temperature measuring range: -50 ... +350 °C / Metal mesh Measuring insert: 1x Pt 100 in two-wire circuit Installation length: 60 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: Shielded connecting cable Available as single and dual resistance thermometers Available in straight and angled versions to meet different installation requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: Laboratory technology Climate cabinets Solar systems Heating, air conditioning, ventilation Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments.This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.
Push-in resistance thermometer with spiralised connection cable, one-piece stainless steel protection tube Type: 902150/30-388-1003-1-6-100-11-2500/315,317 Temperature measuring range: -50 ... +260 °C / metal braiding Measuring insert: 1x Pt 100 in two-wire circuit Installation length: 100 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: with bend protection, cable shielded Available as single and double resistance thermometers Available in straight and angled versions to meet different installation requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: Areas of application: Laboratory technology Climate cabinets Solar systems Heating, air conditioning, ventilation Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments. This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.
Push-in resistance thermometer with spiralised connection cable, one-piece stainless steel protection tube Type: 902150/30-388-1001-1-6-100-11-2500/315,317 Temperature measuring range: -50 ... +260 °C / metal mesh Measuring insert: 1x Pt 100 in three-wire circuit Installation length: 100 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: with bend protection, cable shielded Available as single and double resistance thermometers Available in straight and angled versions to meet different installation requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: Areas of application: Laboratory technology Climate cabinets Solar systems Heating, air conditioning, ventilation Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments. This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.
Push-in resistance thermometer with spiralised connection cable, one-piece stainless steel protection tube Type: 902150/30-402-1001-1-6-150-11-2500/315,317 Temperature measuring range: -50 ... +400 °C / Metal mesh Measuring insert: 1x Pt 100 in three-wire circuit Installation length: 150 mm Cable length: 2500 mm Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: with bend protection, cable shielded Available as single and double resistance thermometers Available in straight and angled versions to meet different installation requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: Areas of application: Laboratory technology Climate cabinets Solar systems Heating, air conditioning, ventilation Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments. This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.
Push-in resistance thermometer with spiralised connection cable, one-piece stainless steel protection tube Type: 902150/20-730-1003-1-6-50-11-1100/000 Temperature measuring range: -5 ... +105 °C Measuring insert: 1x Pt 100 in two-wire circuit Installation length: 50 mm Cable length: 1100 mm (stretched) Tolerance class: Class B (standard) Thermowell diameter: 6 mm Wire end ferrules Extra code: without Available as single and dual resistance thermometers Available in straight and angled versions to meet different mounting requirements. Flexible connection cables Strain relief to protect against mechanical stress Meets SIL and PL qualification standards for maximum safety Optional kink protection Areas of application: Laboratory technology Climate cabinets Solar systems Heating, air conditioning, ventilation Apparatus engineering The insertion resistance thermometer offers precise temperature measurement in both liquid and gaseous media. The wide range of variants makes it ideal for various applications in industrial environments. This thermometer ensures reliable performance in dry and damp rooms and enables accurate temperature measurements. The robust design and flexible configuration options ensure precise temperature monitoring.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1003-1/000 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1005-1/000 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1003-1/903, Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Cable gland (IP65) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/15-361-1005-1/903 Measuring range from -50 to +90°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Cable gland (IP65) Protection class IP65 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/11-635-1003-1/000 Measuring range from -20 to +80°C Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: without Protection class IP54 Suitable for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-572-1001-1/00 Measuring range from -30 to +80°C Measuring insert 1x temperature sensor Pt100 in three-wire circuit Transmitter: without Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-572-1005-1/000 Measuring range from -30 to +80°C Measuring insert 1x temperature sensor Pt1000 in two-wire circuit Transmitter: without Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-803-1003-1/330,(0..40°C) Measuring range from 0 to +40°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x Analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 t-w) (0-40°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-807-1003-1/330,(0..60°C) Measuring range from 0 to +60°C (Measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 4 to 20 mA (only in conjunction with 1x Pt100 t-w) (0-60°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Room, outdoor and duct resistance thermometers Typ: 902520/10-803-1003-1/333,(0..40°C) Measuring range from 0 to +40°C (measuring range only in conjunction with transmitter) Measuring insert 1x temperature sensor Pt100 in two-wire circuit Transmitter: 1x analog transmitter, output 0 to 10V (only in conjunction with 1x Pt100 t-w) (0-60°C) Protection class IP20 Suitabel for use in air conditioning technology Room, outdoor and duct resistance thermometers are designed for air conditioning technology and are mainly used for temperature measurement in rooms, air ducts and outdoors. Various plastic device versions with different degrees of protection are available for the respective measuring task. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is installed as standard, but variants with Pt500, Pt1000, Ni1000 and various NTC sensors are also possible. The connection terminals allow optional continuation in three- and four-wire circuits. An integrated measuring transducer can also be selected as an option.
Screw-in resistance thermometer with connecting cable with fixed screw connectionType: 902050/10-380-1001-1-6-100-104-11-2500/316Silicone connecting cables Temperature range from -50 to +200 °C With fixed screw connection Single resistance thermometer 1x Pt 100 in three-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: 6 mm Installation length 100 mm Process connection: G1/2 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connecting cable and loose screw connectionType: 902050/20-402-1003-1-6-37-114-11-2500/315,317Metal braided connection cablesTemperature range from -50 to +400 °CWith loose screw connectionSingle resistance thermometer1x Pt 100 in two-wire circuitTolerance class according to DIN EN 60 751: Class B (standard)Thermowell diameter: 6 mmInstallation length 37 mmProcess connection: M 10x1 screw connectionConnection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard)Connection cable length: 2500 mmExtracode: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connecting cable and loose screw connectionType: 902050/20-402-1001-1-6-37-114-11-2500/315,317Metal braided connection cablesTemperature range from -50 to +400 °CWith loose screw connectionSingle resistance thermometer1x Pt 100 in three-wire circuitTolerance class according to DIN EN 60 751: Class B (standard)Thermowell diameter: 6 mmInstallation length 37 mmProcess connection: M 10x1 screw connectionConnection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard)Connection cable length: 2500 mmExtracode: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C. The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000. In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection cable and threaded protection tube Type: 902050/40-390-1003-1-8-25-111-11-2500/315,317 Metal braided connection cables Temperature range from -50 to +300 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: M 8 Insertion length 25 mm Process connection: M 8 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm Extra code: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media.The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C.The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection.The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000.In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection cable and threaded protection tube Type: 902050/40-390-1003-1-8-25-111-11-2500/315,317 Metal braided connection cables Temperature range from -50 to +300 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class according to DIN EN 60 751: Class B (standard) Thermowell diameter: M 8 Insertion length 25 mm Process connection: M 8 screw connection Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard) Connection cable length: 2500 mm Extra code: Spring bend protection, connection cable shielded The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media.The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C.The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection.The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000.In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Screw-in resistance thermometer with connection head form J Type: 902030/31-380-1003-1-6-75-104/000 with stepped protection tube for air measurement Measuring range from -50 to +200 °C Single resistance thermometer 1x Pt 100 in two-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6 mm Installation length: 75 mm Process connection: G1/2 threaded connection Extra codes: none The screw-in RTD temperature probe with connection head is specially designed for use in various industries such as air conditioning and refrigeration technology and heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media, with a temperature range of -50 to +400 °C. The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The measuring insert is fitted as standard with a Pt100 temperature sensor in accordance with the DIN EN 60751:2009 / IEC 60751:2008 standards. This sensor has a temperature coefficient α of 3.850 × 10-3 °C-1 and is installed in a two-wire circuit. Versions with Pt500 or Pt1000 are also available as an option. For more precise measurement results, the connection can be made either in a three-wire or four-wire circuit, and it is also possible to integrate a transmitter into the connection head.
JUMO Dtrans T100 screw-in RTD temperature probe without transmitter, M12 x 1 machine plug connection Type: 902815/10-380-1011-1-6-100-104-24/000 Measuring range from -50 to + 200 °C 1x Pt100 in four-wire circuit Tolerance class: Class B (standard) Thermowell diameter: 6 mm Installation length: 100 mm Process connection: G1/2 screw connection Thermowell material: Stainless steel 316 L (material no. 1.4404/1.4435) EU and China RoHS compliant Extra code: without M12 x 1 push-on connector; protection class IP67 to DIN EN 60529 with attached machine plug USB interface for configuration with setup programme The screw-in resistance thermometer in a compact design consists of a thermowell with built-in temperature sensor, a process connection and a housing for the transmitter electronics. The programmable two-wire transmitter offers a robust solution for the precise recording of temperatures in a temperature measuring range of -50 to + 150°C, with a neck tube up to 260°C and is therefore versatile in use. The device has a USB interface that enables simple configuration via a setup programme. With the help of this programme, parameters such as measuring range, fine adjustment and measuring circuit monitoring can be adjusted to meet the requirements of different applications. The output signal 4 to 20 mA or reversed 20 to 4 mA is available linearised (temperature linear). The device is intended for industrial use and complies with European standards to ensure electromagnetic compatibility (EMC).
JUMO Dtrans T100 screw-in RTD temperature probe without transmitter, M12 x 1 machine plug connection Type: 902815/10-380-1011-3-6-50-104-24/000 Measuring range from -50 to + 200 °C 1x Pt100 in four-wire circuit Tolerance class: Class AA Thermowell diameter: 6 mm Installation length: 50 mm Process connection: G1/2 screw connection Thermowell material: Stainless steel 316 L (material no. 1.4404/1.4435) EU and China RoHS compliant Extra code: without M12 x 1 push-on connector; protection class IP67 to DIN EN 60529 with attached machine plug USB interface for configuration with setup programme The screw-in resistance thermometer in a compact design consists of a thermowell with built-in temperature sensor, a process connection and a housing for the transmitter electronics. The programmable two-wire transmitter offers a robust solution for the precise recording of temperatures in a temperature measuring range of -50 to + 150°C, with a neck tube up to 260°C and is therefore versatile in use. The device has a USB interface that enables simple configuration via a setup programme. With the help of this programme, parameters such as measuring range, fine adjustment and measuring circuit monitoring can be adjusted to meet the requirements of different applications. The output signal 4 to 20 mA or reversed 20 to 4 mA is available linearised (temperature linear). The device is intended for industrial use and complies with European standards to ensure electromagnetic compatibility (EMC).