Skip to main content Skip to search Skip to main navigation

Testomat® indicator TH 2025 2x100ml

Product number: 151025
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat® indicator TH 2025 2x100ml"

Original Testomat indicator TH2025, two 100 ml bottles for precise determination of residual hardness in water. The indicator reliably covers the measuring range from 0.25 to 2.50 °dH.

Testomat indicator TH2025 2x100ml – residual hardness measuring solution

Precise indicator solution for measuring residual hardness

The Testomat Indicator TH2025 is a high-quality indicator solution for determining residual hardness in water. The practical 100 ml bottles can be used directly in Testomat devices without cumbersome decanting or additional preparation. The indicator measures residual hardness in the range from 0.25 to 2.50 °dH.

Where can the indicator be used?

  • Laboratory analyses
  • Water treatment & drinking water testing
  • Industry & process control
  • Domestic water technology

Technical measurement data of the indicator

  • Measurement parameter: Residual hardness in water
  • Measuring range: °dH (resolution): 0.25–2.50 (0.05), °f (resolution): 0.45–4.48 (0.10), ppm CaCO3 (resolution): 4.48–44.8 (0.9), mmol/l (resolution): 0.04–0.45 (0.01)
  • Scope of delivery: 2 x 100 ml ready-to-use indicator solution
  • Compatible analysers: Testomat 2000, Testomat 2000 CAL, Testomat 2000 DUO, Testomat 2000 V, Testomat ECO, Testomat EVO TH
  • Advantages: Ready to use, original indicator from Heyl, suitable for Testomat 2000®, Testomat 2000® CAL, Testomat 2000® DUO, Testomat 2000® V, Testomat ECO®, Testomat® EVO TH. The original bottles can be used immediately in the Testomat devices without any complicated decanting

Please note that a different bottle insert than the one supplied is required for the 100 ml bottle (conversion kit 100 ml bottle for T2000/ECO/EVO item number 40143).

Buy Testomat Indicator TH2025 2x100ml online now!

Get a 3% online shop discount on all Heyl items. Benefit from fast delivery and expert advice.

Do you have any questions about the product? We are also happy to answer your questions by telephone.

Frequently asked questions

The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months.

When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.).

The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis.

By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator:
Indicators - Consumption calculator - Heyl Neomeris

The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143).

The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets.

Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations.

The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed.

Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C.

Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.

Dimensions

Height 6,5 cm
Length 12,5 cm
Width 11,5 cm

Weight

Weight 280 g

Other attributes

Country of origin EU
Customs tariff number 38221900
Skip product gallery

We recommend the following

Conversion kit for 100 ml bottle, front view, suitable for Testomat 2000, ECO, and EVO, insert for screw cap with suction tube
Conversion kit 100 ml bottle for T2000/ECO/EVO
Product number: 40143

Conversion kit for 100 ml bottle For inserting 100 ml bottles instead of 500 ml bottles Technical data: 100 ml bottle insertion for screw top with suction pipe for 100 ml bottles screw top GL32   