Testomat® indicator TH 2250 2x100ml

Product number: 151250
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat® indicator TH 2250 2x100ml"

2x100 ml Testomat indicator TH2250 for determining residual hardness in water in the range 2.50-25.00 °dH. Suitable for various Testomat devices.

Testomat indicator TH2250 2x100ml – measuring solution for residual hardness of 2.50-25.00 °dH

Original indicator for precise measurement of residual hardness in water with a wide measuring range

The Testomat Indicator TH2250 in 2x100 ml is used for the automated determination of residual hardness in water analyses. The indicator covers an extended measuring range from 2.50 to 25.00 °dH and is particularly suitable for medium to high water hardness. It delivers precise results thanks to defined resolutions in °dH, °f, ppm CaCO3 and mmol/l. With a guaranteed minimum shelf life of 7 months after dispatch from our warehouse, the solution can be stored safely and used reliably over this period without compromising measurement accuracy.

Wide measuring range for medium to high water hardness

With a measuring range from 2.50 to 25.00 °dH, the TH2250 indicator covers a large part of the usual water hardness spectrum found in technical processes, heating water systems or industrial water treatment. The respective resolution ensures fine gradation and precise results, which are indispensable for correct conclusions and process control.

  • Measuring parameter: Residual hardness
  • Measuring range: Unit °dH: 2.50–25.00, °f: 4.48–44.8, ppm CaCO3: 44.8–448, mmol/l: 0.45–4.48

Compatibility of the indicator

The TH2250 indicator is compatible with Testomat® measuring systems such as Testomat 2000®, Testomat 2000® CAL, Testomat 2000® DUO, Testomat 2000® V, Testomat 2000® Self Clean, Testomat ECO®, Testomat ECO® Plus and Testomat® EVO TH.

The original bottles can be used directly in Testomat devices without the need for cumbersome decanting.

Order the Testomat indicator TH2250 2x100 ml conveniently online now!

Benefit from a 3% price advantage on all Heyl products in our online shop and enjoy fast shipping and expert advice.

Do you have any questions about this product?

Our team will be happy to advise you by telephone.

Frequently asked questions

The shelf life of an indicator is printed on the product label for each batch. In accordance with our terms and conditions, we deliver with a guaranteed minimum shelf life of 7 months.

When it comes to indicator consumption, a distinction must first be made between TH indicators (e.g. TH 2005, 2025, 2050, etc.), which are used for the Testomat ECO, Testomat EVO TH, Testomat 2000 and Testomat Limit LT analysis devices, and the indicators for the Testomat 808 (300 series indicators, e.g. indicators 301, 305, etc.).

The indicator consumption per analysis for the TH indicators is directly related to the limit value to be monitored. The higher this is, the higher the indicator consumption. For the Testomat 808 indicators (300 series), consumption is approximately 80 µl per analysis.

By entering the operating data (analysis interval, limit value, etc.), the exact consumption or indicator requirement per year can be determined using our indicator consumption calculator:
Indicators - Consumption calculator - Heyl Neomeris

The indicator is available in both 500 ml and 100 ml bottles. The analyser is delivered with the 500 ml bottle set up and the scope of delivery includes the screw cap with hole and insert for the screw cap of the 500 ml indicator bottle. To use 100 ml bottles, the bottle size must be changed to 100 ml in the basic programming, and the screw cap with hole and insert for the indicator must also be purchased (item no. 40143).

The safety data sheets can be found in the online shop (www.heylneomeris.shop) under the menu item – Service/Help – Downloads Safety Data Sheets.

Disposal instructions can be found in section 13 of the safety data sheet. Disposal must be carried out in accordance with official regulations.

The indicator can no longer be used after the expiry date. After the expiry date, accurate measurement results can no longer be guaranteed.

Section 7 of the safety data sheet contains all relevant information on storing the indicator. The recommended storage temperature should be between 15-25°C.

Measurement errors when using third-party indicators! The use of third-party indicators can lead to large measurement deviations or measurement errors. Damage caused by foreign particles in the area of the dosing pump, measuring chamber or valves is also possible. The use of third-party indicators will void the warranty! Only use original Heyl indicators, which are specially designed to meet the requirements of the measuring devices and thus guarantee accurate measurement results.

Dimensions

Height 6,5 cm
Length 12,5 cm
Width 11,5 cm

Weight

Weight 300 g

Other attributes

Country of origin EU
Customs tariff number 38221900
Skip product gallery

We recommend the following

Conversion kit for 100 ml bottle, front view, suitable for Testomat 2000, ECO, and EVO, insert for screw cap with suction tube
Conversion kit 100 ml bottle for T2000/ECO/EVO
Product number: 40143

Conversion kit for 100 ml bottle For inserting 100 ml bottles instead of 500 ml bottles Technical data: 100 ml bottle insertion for screw top with suction pipe for 100 ml bottles screw top GL32   

€53.40*