Skip to main content Skip to search Skip to main navigation

Milwaukee PH600 Digital pH Pen

Article number: 895500
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee PH600 Digital pH Pen"

Compact digital pH tester for the rapid determination of pH levels in liquids. The Milwaukee PH600 stands out thanks to its ease of use, easy-to-read display, manual 1-point calibration, and long battery life. Ideal for aquariums, hydroponics, water analysis, and many other applications.

Milwaukee PH600 digital pH tester – Simple operation for quick measurements

The Milwaukee PH600 is a compact digital pH tester that enables fast and straightforward pH measurements across various applications. Its handy design makes the device ideal for mobile use, allowing for reliable on-site pH monitoring.

The measurement range covers the entire pH spectrum—from highly acidic to highly alkaline solutions—making the PH600 a versatile tool for aquariums, hydroponics, water analysis, horticulture, laboratory work, and many other fields. The easy-to-read LCD display ensures convenient reading of measurements and makes the device simple to operate, even for users without extensive experience in measurement technology.

To ensure reliable accuracy, the pH tester features manual 1-point calibration. This allows the device to be quickly recalibrated whenever necessary, guaranteeing consistently precise results. Additionally, the long battery life ensures reliable operation over extended periods, making the Milwaukee PH600 a practical companion for routine checks.

Thanks to its ease of use, compact design, and reliable measurement technology, the Milwaukee PH600 is suitable for both private and professional users seeking a cost-effective pH measurement solution.

Benefits

  • Compact and handy pH tester
  • Manual 1-point calibration
  • Long battery life
  • Suitable for mobile and stationary applications
  • Versatile use across various fields
  • Measurement parameter: pH
  • Measurement range: 0.0 to 14.0 pH

Typical applications

  • Aquaristics
  • Hydroponics
  • Water analysis
  • Horticulture
  • Laboratory applications
  • Education and training
  • General pH monitoring

Frequently Asked Questions

You see the reading immediately after immersion.

Yes, you can use it for plants, soil, hydroponics, and pools.

Yes, you can simply switch it on, take a measurement, and read the value directly.

The measurements are very reliable and help you ensure proper care.

No, the device automatically adjusts to different temperatures.

Yes, you can quickly see whether the pH level is optimal for healthy plants.

Yes, it is designed for daily use in the garden or around the house.

Dimensions

Height 3 cm
Length 18 cm
Width 6,5 cm

Weight

Weight 80 g

Other attributes

Applications Aquaculture and Coral, Beer, Beverages, Environmental, Horticulture, Pools, Schools, Water Conditioning, Water Treatment
Brand Milwaukee
Country of origin RO
Customs tariff number 90278930
Parameter pH
Quality Basic
Specifications
Measuring range: 0.0 to 14.0 pH
Resolution: 0.1 pH
Accuracy: ±0.1 pH
Typical EMC Deviation: ±0.2 pH
Calibration: Manual, 1 point through trimmer
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type: 4 x 1.5V Alkaline (included)
Battery Life: Approx. 350 hours of continuous use
Skip product gallery

Spare parts and accessories

Milwaukee M10004B pH 4.01 calibration solution, front of bag with product name and volume
Milwaukee M10004B pH 4.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895526

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10007B pH 7.01 calibration solution bag front, 25 bags of 20 ml visible, calibration solution pH 7.01 for accurate measurements
Milwaukee M10007B pH 7.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895527

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10010B pH 10.01 calibration solution bag front, 25 bags of 20 ml each, calibration solution pH 10.01 for precise pH measurement, Milwaukee pH 10 calibration solution in a practical bag, pH 10 reference solution for calibrating measuring devices
Milwaukee M10010B pH 10.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895528

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee storage solution, 230ml (MA9015) Product number: 896165
Milwaukee storage solution, 230ml (MA9015)
Article number: 896165

for pH/ORP electrodes

€43.40*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€46.40*