Skip to main content Skip to search Skip to main navigation

Printer cable for HORIBA 200/300/1500/2000 series – 25-pin with phono plug

Article number: 895938
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information " Printer cable for HORIBA 200/300/1500/2000 series – 25-pin with phono plug"

This specially designed printer cable enables a reliable connection between the portable and stationary measuring devices of the HORIBA 200, 300, 1500 and 2000 series portable and stationary measuring instruments and a compatible printer with a 25-pin Sub-D connection. The integrated phono plug ensures a secure and precise connection to the instrument – ideal for direct output of measurement results in the laboratory or in the field.

Manufacturer article number: 3200779638

Other attributes

Country of origin JP
Customs tariff number 90279000
Skip product gallery

Empfohlenes Zubehör

Horiba LAQUA WQ310-K handheld meter with pH electrode, front view
Horiba LAQUA WQ310-K - 1 channel professional measuring device for various parameters in analysis case
Article number: 895750

Thank you for your interest in our smart and customizable Horiba WQ-300 series instruments.The high-quality digital multi-parameter handheld meters with their generous color LCD display with LED backlight (7 cm x 5.2 cm) are ideally suited for use in the field under all conditions and in direct daylight.Use our configurator to freely select the suitable measuring device of the WQ-300 Horiba series (1 to 3 channels), the measuring parameters (sensor cartridges) and desired cable length (with integrated sensor receptacle + digital module) according to your wishes and requirements. At a later stage, you can always connect another available measurement parameter to the device via the corresponding sensor cable or carry it in the case as a supplement. As with other handheld measuring devices from Horiba, a major advantage of these devices is that the measuring devices are highly resistant to shock, slipping and scratching thanks to a special rubber coating. Only four standard AA 2500 mAh batteries are required for operation, and to give you more flexibility when you are on the move, the WQ-300 series devices can also be powered by a powerbank or battery pack via the integrated USB interface. The IP67 certification, which certifies dustproofness and protection against temporary submersion for up to 30 minutes at a water depth of one meter, completes the overall professional package, along with the usual ergonomic design and ease of user operation.  Horiba attests to its outstanding product quality by offering a three-year warranty on the LAQUA WQ-300 series handheld meters. Other added values and features:During analyses, the user is supported by the display of operating instructions in the form of smiley icons, which is supplemented by an LED status display on the sensor. This is intended to prevent operating errors, which can lead to implausible measurement results. The design decision to install only a small number of control buttons and not to implement any nested user menus serves to ensure that the devices can be operated easily and safely even during discontinuous use as well as when used by other users.  The measuring instruments have an electrode wear indicator, a measuring stability indicator on the instrument and sensor, a locking function to "save" the currently measured value on the display, free naming of the measuring point (8 characters), automatic calibration functions, integrated sensor holders, self-diagnosis function, as well as GLP functions. The fold-out stand on the back of the instruments means that you always have your hands free to carry out your measurements easily and safely. Measurement data can be conveniently transferred to your computer or cell phone via USB or WiFi.All handheld meters of the 300 series are delivered in a reinforced measuring case for mobile use in the open air. This provides space for the meter, for electrodes and cables, for up to eight 60 ml bottles of buffer solutions including an integrated buffer solution bottle holder for easier calibration. Particularly noteworthy is the automatic sensor recognition of the instrument through the use of sensor cables with integrated digital sensor recording. Information about the sensor, calibration data as well as measurement settings are stored in the sensor recording and transmitted to the measuring instrument. In addition, calibration of all connected sensors is possible at the same time, since each sensor head independently stores the measurement and calibration data and transmits it to the WQ300 series measuring device.Optionally, there is the possibility to connect and use analog sensors via the Horiba BNC sensor adapter with the device, please contact us for this.Languages:GermanEnglishFrenchSpanishPortugueseChineseScope of delivery:WQ-300 series handheld meter in a carrying casethe digital electrode you have chosen, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptaclemanualManufacturer article number single measuring device WQ-310-K 1 channel: 3200832605 Note: Chloride sensor, if selected, is supplied without chloride ion strength regulator and chloride electrode filling solution. This must be procured by the customer. Without the filling solution the sensor can´t be used. Why We Use These Measuring Devices in Water Treatment Precise calcium control is a key element of efficient water treatment – from drinking water purification and process water management to environmental analysis. Elevated calcium levels can lead to scaling, pipe damage, energy losses, and disruptions in chemical processes. For this purpose, we offer tailored high-end solutions from the Horiba LAQUA WQ Series (WQ310-K, WQ320-K, WQ330-K) in our online shop, specifically designed to meet the needs of water technology:  WQ310-K: Single-parameter solution for targeted measurements • WQ320-K: Simultaneous monitoring of, for example, calcium and conductivity • WQ330-K: Three-channel measurement for complex real-time multi-parameter analyses Why We Rely on These Devices: • They provide reliable data for controlling and optimizing water treatment systems • They offer digital evaluation, documented results, and interfaces for process integration • They are robust, packaged in a practical analysis case, and thus also suitable for mobile on-site use • They allow calcium to be measured in combination with other parameters such as pH, conductivity, or redox – for a holistic and efficient approach

€485.00*
Horiba LAQUA WQ‑320‑K front view of handheld meter, IP67 protection, integrated sensor head.
Horiba LAQUA WQ320-K - 2 channel professional measuring device for various parameters in analysis case
Article number: 895751

Thank you for your interest in our smart and customizable Horiba WQ-300 series instruments.The high-quality digital multi-parameter handheld meters with their generous color LCD display with LED backlight (7 cm x 5.2 cm) are ideally suited for use in the field under all conditions and in direct daylight.Use our configurator to freely select the suitable measuring device of the WQ-300 Horiba series (1 to 3 channels), the measuring parameters (sensor cartridges) and desired cable length (with integrated sensor receptacle + digital module) according to your wishes and requirements. At a later stage, you can always connect another available measurement parameter to the device via the corresponding sensor cable or carry it in the case as a supplement. As with other handheld measuring devices from Horiba, a major advantage of these devices is that the measuring devices are highly resistant to shock, slipping and scratching thanks to a special rubber coating. Only four standard AA 2500 mAh batteries are required for operation, and to give you more flexibility when you are on the move, the WQ-300 series devices can also be powered by a powerbank or battery pack via the integrated USB interface. The IP67 certification, which certifies dustproofness and protection against temporary submersion for up to 30 minutes at a water depth of one meter, completes the overall professional package, along with the usual ergonomic design and ease of user operation.  Horiba attests to its outstanding product quality by offering a three-year warranty on the LAQUA WQ-300 series handheld meters. Other added values and features:During analyses, the user is supported by the display of operating instructions in the form of smiley icons, which is supplemented by an LED status display on the sensor. This is intended to prevent operating errors, which can lead to implausible measurement results. The design decision to install only a small number of control buttons and not to implement any nested user menus serves to ensure that the devices can be operated easily and safely even during discontinuous use as well as when used by other users.  The measuring instruments have an electrode wear indicator, a measuring stability indicator on the instrument and sensor, a locking function to "save" the currently measured value on the display, free naming of the measuring point (8 characters), automatic calibration functions, integrated sensor holders, self-diagnosis function, as well as GLP functions. The fold-out stand on the back of the instruments means that you always have your hands free to carry out your measurements easily and safely. Measurement data can be conveniently transferred to your computer or cell phone via USB or WiFi.All handheld meters of the 300 series are delivered in a reinforced measuring case for mobile use in the open air. This provides space for the meter, for electrodes and cables, for up to eight 60 ml bottles of buffer solutions including an integrated buffer solution bottle holder for easier calibration. Particularly noteworthy is the automatic sensor recognition of the instrument through the use of sensor cables with integrated digital sensor recording. Information about the sensor, calibration data as well as measurement settings are stored in the sensor recording and transmitted to the measuring instrument. In addition, calibration of all connected sensors is possible at the same time, since each sensor head independently stores the measurement and calibration data and transmits it to the WQ300 series measuring device.Optionally, there is the possibility to connect and use analog sensors via the Horiba BNC sensor adapter with the device, please contact us for this.Languages:GermanEnglishFrenchSpanishPortugueseChineseScope of delivery:WQ-300 series handheld meter in a carrying casethe digital electrode you have chosen, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptaclemanualManufacturer article number single measuring device WQ-320-K 2 channel: 3200832606 Note: Chloride sensor, if selected, is supplied without chloride ion strength regulator and chloride electrode filling solution. This must be procured by the customer. Without the filling solution the sensor can´t be used.

€535.00*
Tip
Horiba LAQUA WQ‑330‑K handheld meter with three connected electrodes, front view, robust design.
Horiba LAQUA WQ330-K - 3 channel professional measuring device for various parameters in analysis case
Article number: 895752

Horiba WQ330-K – Your Professional 3-Channel Water Quality Meter Expandable multi-parameter system for simultaneous measurement of pH, conductivity, redox, and other water parameters The Horiba LAQUA WQ330-K is a powerful multi-channel device for advanced water analysis, both on-site and in the laboratory. With three freely configurable measurement channels, it can simultaneously record parameters such as pH, conductivity, redox potential, TDS, temperature, oxygen, ammonia, calcium, chloride, nitrate, fluoride, and potassium. Intuitive operation, automatic sensor recognition, and digital calibration ensure accurate, fast, and reproducible measurements. Flexible Multi-Parameter System for Field and Laboratory Applications The analysis kit with the Horiba WQ330-K is ideal for environmental and water body monitoring, research and teaching, as well as drinking and process water control. The large LCD display with LED backlight ensures excellent readability even in direct sunlight. Measurement data can be exported and documented via USB or wirelessly, greatly simplifying traceability and analysis. The modular system allows the device to be quickly and precisely adapted to any measurement task. It is ideal for users who need to efficiently and reliably monitor multiple water parameters. Technical Features and Key Advantages of the WQ330-K The three measurement channels of the Horiba WQ330-K enable simultaneous recording of different water parameters, reducing measurement time and allowing better evaluation of relationships between parameters. The modular sensor concept allows flexible use of digital sensors, which are automatically recognized and store their calibration history. Notably, the combination of high measurement precision, user-friendliness, and mobility makes this device stand out. Quick deployment without complicated setup, along with easy data transfer for documentation and analysis, makes the Horiba LAQUA WQ330-K an ideal solution for professional water analytics. Frequently asked questions How long is the warranty period for HORIBA analysers? The warranty period is 2 years for the 300 (WQ) series and 1 year for the F series after delivery. Where can I find suitable replacement electrodes or buffer solutions? You can find the appropriate replacement electrodes and buffer solutions in the shop under the main item at the bottom of the cross-selling section. How do I clean the probe before calibration? The sensors should be cleaned with DI water (deionised). After cleaning, wipe them with tissue paper if possible.

€585.00*
Horiba LAQUA EC1500 laboratory device with power adapter, electrode stand and standard solutions
Horiba LAQUA EC1500 Single Channel Meter Starter Kit
Article number: 895828
Version: starter-set

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our high-end benchtop model was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate measurements  Accepts up to 5 conductivity calibration points Automatic calibration at 84μS/cm, 1413μS/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applicationsScope of delivery: Measuring device with integrated electrode stand Universal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9382-10D plastic body conductivity electrode, cell constant k=1.0 84 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard (1 x 250ml each) with electrode holder Manufacturer article number:1300095721 (EC1500-S)

€745.00*
Horiba LAQUA EC1500 (meter only)
Horiba LAQUA EC1500 (meter only)
Article number: 895839
Version: meter only

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our high-end benchtop model was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate measurements  Accepts up to 5 conductivity calibration points Automatic calibration at 84μS/cm, 1413μS/cm, 12.88mS/cm, & 111.8mS/cm standards Displays average calibration factor Selectable cell constant Allows 1-point salinity calibration and temperature calibration Pre-programmed TDS and salinity curves for various applicationsScope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9382-10D plastic body conductivity electrode, cell constant k=1.0 84 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard (1 x 250ml each) with electrode holder

€365.00*
Tip
Horiba LAQUA EC2000 laboratory measuring device front view, large 5-inch display with measurement value and temperature reading
Horiba LAQUA EC2000 dual-channel multiparameter bench-top laboratory meter starter set
Article number: 895831
Version: starter-set

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. With the electrode stand included in the scope of delivery, two electrodes can be held and adjusted in height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the Laqua EC2000 model (multi-parameter): The EC2000 is a measuring instrument which evaluates the conductivity in various measuring ranges and also measures the TDS, resistance, salinity and temperature values. Conductivity-resistivity-TDS-salinity wide measuring range from 0.001μS/cm to 2,000 S/cm  allows automatic and manual conductivity calibrations  records individual and average calibration factors after conductivity calibration  Calculates resistance, TDS and salinity based on measured conductivity  7 conductivity ranges:   0.000 to 1.999 μS/cm (k = 0.1)  2.00 to 19.99 μS/cm (k = 0.1, 1)  20.0 to 199.9 μS/cm (k = 0.1, 1, 10)  200 to 1999 μS/cm (k = 0.1, 1, 10)  2.00 to 19.99 mS/cm (k = 0.1, 1, 10)  20.0 to 199.9 mS/cm (k = 1, 10)  0.200 to 2.000 S/cm (k = 10) Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm) Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring device with integrated electrode stand Universal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9382-10D conductivity electrode with plastic body, cell constant k=1.0 84 µS/cm, 1413 µS/cm, 12.88 mS/cm (1 x 250ml each) Flow cell available in combination with 9371-10 stainless steel conductivity cell for ultrapure water measurement (300-2C-C) Manufacturer part number:Meter only   EC2000 (3200896965) Starter-set   EC2000-S (1300098881)

€830.00*
Tip
Horiba LAQUA EC2000 (double channel meter only) Product number: 895843
Horiba LAQUA EC2000 (double channel meter only)
Article number: 895843
Version: meter only

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. The electrode stand included in the starter set can be used to hold two electrodes and adjust their height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the Laqua EC2000 model (multi-parameter): The EC2000 is a measuring instrument which evaluates the conductivity in various measuring ranges and also measures the TDS, resistance, salinity and temperature values. Conductivity-resistivity-TDS-salinity wide measuring range from 0.001μS/cm to 2,000 S/cm  allows automatic and manual conductivity calibrations  records individual and average calibration factors after conductivity calibration  Calculates resistance, TDS and salinity based on measured conductivity  7 conductivity ranges:   0.000 to 1.999 μS/cm (k = 0.1)  2.00 to 19.99 μS/cm (k = 0.1, 1)  20.0 to 199.9 μS/cm (k = 0.1, 1, 10)  200 to 1999 μS/cm (k = 0.1, 1, 10)  2.00 to 19.99 mS/cm (k = 0.1, 1, 10)  20.0 to 199.9 mS/cm (k = 1, 10)  0.200 to 2.000 S/cm (k = 10) Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm). Electrode holder only included in the starter set.Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9382-10D conductivity electrode with plastic body, cell constant k=1.0 84 µS/cm, 1413 µS/cm, 12.88 mS/cm (1 x 250ml each)with electrode holder Flow cell available in combination with 9371-10 stainless steel conductivity cell for ultrapure water measurement (300-2C-C) Manufacturer part number:Meter only   EC2000 (3200896965) Starter-set   EC2000-S (1300098881)

€460.00*
Tip
Horiba LAQUA ION2000 benchtop device front view with display showing measurement value and menu information
Horiba LAQUA ION2000 Laboratory Table Meter Multiparameter
Article number: 895842
Version: meter only

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to four decimal places in this version (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. With the electrode stand included in the scope of delivery, two electrodes can be held and adjusted in height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the Laqua ION2000 model : The ION2000 is a laboratory meter to which you can connect the separately available ion-selective Horiba probes or determine the pH value and the redox value via the electrodes. Single input, connection of one electrode. Ions (ammonia, calcium, chloride, fluoride, nitrate, potassium)  Measurement ion-selective  accepts combined and half-cell ion-selective electrodes  wide measuring range from 0.000 μg/L to 9999 g/L  accepts up to 5 user-defined ion calibration points  choice of preferred units: μg/L - mg/L - g/L, ppm - ppt, mmol/L - mol/L  Resolution of 4 significant digits after the decimal point with automatic scaling  pH-ORP wide measuring range; -2.000 to 20.000 pH  high accuracy; ± 0.003 pH  resolution: 0.1, 0.01 or 0.001 pH  continuous display of calibrated points  display of offset and slope - by segment and average up to 5 pH  calibration points ± 2000.0 mV  1-point redox calibration  automatically recognises and calibrates USA, NIST, NIST2 and DIN pH buffers  allows CUST (Custom) buffers for manual calibration  Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series:  internal memory for up to 2000 data sets, measurement data with time and date information  records and stores data in the unit memory based on a specified time interval  a 4-digit password protects the meter set-up mode from unauthorised access  data can be transferred to a computer and exported in the following formats CSV/Excel/PDF  GLP/GMP compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument  Software updates can be downloaded to the instrument  Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days)  Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm)  Displays measurement stability in measurement and calibration mode  displays electrode condition based on calibration data  smooth surface, easy cleaning  RS-232/USB, therefore easy PC and printer connection and free instrument software  Ergonomic design for easy viewing and operation  Clearly labelled and easy-to-use ports for communication and measurement  5" digital display with backlight, shows all important measurement values and status  Automatic calibration, recognises a wide range of standard solutions adjustable switch-off time (up to 30 minutes)  temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user  several measuring modes:  Auto-Stable mode signals a stable measured value, Auto-Hold mode holds a stable measured value Real Time mode continuously displays current readings  small meter footprint of 155 x 150 mm, saves valuable space  Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits  Fixed and individual calibration points Easy navigation, navigate through the settings menu by up, down, right and left  Scope of delivery:  Measuring device with integrated electrode stand  Universal mains adapter with 6 plugs  Operating instructions  Manufacturer part number: Meter only ION2000 (3200896963) 

€565.00*
Horiba LAQUA PC1500 dual-channel measuring device starter set front view, LCD display with 100 reading
Horiba LAQUA PC1500 Double Channel Meter Starter Kit
Article number: 895829
Version: starter-set

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our multiparameter laboratory measuring instrument was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting. Simultaneous measurement is possible by connecting two electrodes at the same time.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate measurements Automatic temperature compensation Accepts up to 6 pH- and up to 5 conductivity- calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP-, salinity- and temperature- calibrationScope of delivery: Measuring device with integrated electrode stand Universal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9625-10D refillable pH electrode with plastic body 9382-10D plastic body conductivity electrode, cell constant k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each)84 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard (1 x 250ml each)with electrode holder Manufacturer article number:1300095722 (PC1500-SR)

€1,115.00*
Horiba LAQUA PC1500 (double channel meter only)
Horiba LAQUA PC1500 (double channel meter only)
Article number: 895840
Version: meter only

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our multiparameter laboratory measuring instrument was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting. Simultaneous measurement is possible by connecting two electrodes at the same time.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate measurements Automatic temperature compensation Accepts up to 6 pH- and up to 5 conductivity- calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP-, salinity- and temperature- calibrationScope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9625-10D refillable pH electrode with plastic body 9382-10D plastic body conductivity electrode, cell constant k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each)84 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard (1 x 250ml each)with electrode holder

€480.00*
Tip
Horiba LAQUA PC2000 dual-channel multiparameter benchtop laboratory measuring device starter set front view
Horiba LAQUA PC2000 dual-channel multiparameter bench-top laboratory meter starter set
Article number: 895832
Version: starter-set

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. The electrode stand included in the starter set can be used to hold two electrodes and adjust their height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the Laqua PC2000 model (multi-parameter): The PC2000 is a combination of the ION2000 and the EC2000 with the advantage that you can measure all parameters with one device. Dual input, connection of 2 electrodes at the same time. pH-ORP wide measuring range; -2.000 to 20.000 pH  high accuracy; ± 0.003 pH  resolution: 0.1, 0.01 or 0.001 pH  continuous display of calibrated points  display of offset and slope - by segment and average up to 5 pH  calibration points ± 2000.0 mV  1-point redox calibration  automatically recognises and calibrates USA, NIST, NIST2 and DIN pH buffers  allows CUST (Custom) buffers for manual calibration  Conductivity-resistivity-TDS-salinity wide measuring range from 0.001μS/cm to 2,000 S/cm  allows automatic and manual conductivity calibrations  records individual and average calibration factors after conductivity calibration  Calculates resistance, TDS and salinity based on measured conductivity  7 conductivity ranges:   0.000 to 1.999 μS/cm (k = 0.1)  2.00 to 19.99 μS/cm (k = 0.1, 1)  20.0 to 199.9 μS/cm (k = 0.1, 1, 10)  200 to 1999 μS/cm (k = 0.1, 1, 10)  2.00 to 19.99 mS/cm (k = 0.1, 1, 10)  20.0 to 199.9 mS/cm (k = 1, 10)  0.200 to 2.000 S/cm (k = 10) Ions (ammonia, calcium, chloride, fluoride, nitrate, potassium)  Measurement ion-selective accepts combined and half-cell ion-selective electrodes wide measuring range from 0.000 μg/L to 9999 g/L accepts up to 5 user-defined ion calibration points choice of preferred units: μg/L - mg/L - g/L, ppm - ppt, mmol/L - mol/L Resolution of 4 significant digits after the decimal point with automatic scaling  Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm). Electrode holder only included in the starter set.Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring device with integrated electrode stand Universal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9625-10D refillable pH electrode with plastic body 9382-10D conductivity electrode with plastic body, cell constant k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) 84 µS/cm, 1413 µS/cm, 12.88 mS/cm (1 x 250ml each) with electrode holderFlow cell available in combination with 9371-10 stainless steel conductivity cell for ultrapure water measurement (300-2C-C) Manufacturer part number:Meter only   PC2000 (3200896964) Starter-set   PC2000-SR (1300098882)

€1,320.00*
Tip
Horiba LAQUA PC2000 (double channel meter only) Product number: 895844
Horiba LAQUA PC2000 (double channel meter only)
Article number: 895844
Version: meter only

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. The electrode stand included in the starter set can be used to hold two electrodes and adjust their height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the Laqua PC2000 model (multi-parameter): The PC2000 is a combination of the ION2000 and the EC2000 with the advantage that you can measure all parameters with one device. Dual input, connection of 2 electrodes at the same time. pH-ORP wide measuring range; -2.000 to 20.000 pH  high accuracy; ± 0.003 pH  resolution: 0.1, 0.01 or 0.001 pH  continuous display of calibrated points  display of offset and slope - by segment and average up to 5 pH  calibration points ± 2000.0 mV  1-point redox calibration  automatically recognises and calibrates USA, NIST, NIST2 and DIN pH buffers  allows CUST (Custom) buffers for manual calibration  Conductivity-resistivity-TDS-salinity wide measuring range from 0.001μS/cm to 2,000 S/cm  allows automatic and manual conductivity calibrations  records individual and average calibration factors after conductivity calibration  Calculates resistance, TDS and salinity based on measured conductivity  7 conductivity ranges:   0.000 to 1.999 μS/cm (k = 0.1)  2.00 to 19.99 μS/cm (k = 0.1, 1)  20.0 to 199.9 μS/cm (k = 0.1, 1, 10)  200 to 1999 μS/cm (k = 0.1, 1, 10)  2.00 to 19.99 mS/cm (k = 0.1, 1, 10)  20.0 to 199.9 mS/cm (k = 1, 10)  0.200 to 2.000 S/cm (k = 10) Ions (ammonia, calcium, chloride, fluoride, nitrate, potassium)  Measurement ion-selective accepts combined and half-cell ion-selective electrodes wide measuring range from 0.000 μg/L to 9999 g/L accepts up to 5 user-defined ion calibration points choice of preferred units: μg/L - mg/L - g/L, ppm - ppt, mmol/L - mol/L Resolution of 4 significant digits after the decimal point with automatic scaling  Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm). Electrode holder only included in the starter set.Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9625-10D refillable pH electrode with plastic body 9382-10D conductivity electrode with plastic body, cell constant k=1.0 pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) 84 µS/cm, 1413 µS/cm, 12.88 mS/cm (1 x 250ml each) with electrode holderFlow cell available in combination with 9371-10 stainless steel conductivity cell for ultrapure water measurement (300-2C-C) Manufacturer part number:Meter only   PC2000 (3200896964) Starter-set   PC2000-SR (1300098882)

€720.00*
Horiba LAQUA PH1500 starter set overall view with power adapter, cable and accessories, device with electrode holder, refillable pH electrode and user manual
Horiba LAQUA PH1500 Single Channel Meter Starter Kit
Article number: 895827
Version: starter-set

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our high-end benchtop model was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate pH and ORP measurements Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibrationScope of delivery: Measuring device with integrated electrode stand Universal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9625-10D refillable pH electrode with plastic body pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each)with electrode holder Manufacturer article number:1300095720 (PH1500-SR)

€588.00*
Horiba LAQUA PH1500 single-channel measuring device single view, pH laboratory device without accessories visible
Horiba LAQUA PH1500 (meter only)
Article number: 895838
Version: meter only

Stress-free measurement - professional model Water quality analysis is repeatedly performed in laboratories on a daily basis. Our high-end benchtop model was developed to provide simplicity with excellent on-site usability - from operation and maintenance through to troubleshooting.Ideal for student training and routine applications. Good value for money: no bells and whistles that sounds good but is rarely used. From a renowned manufacturer whose company started with pH meters as early as 1945.Highly accurate pH and ORP measurements Automatic temperature compensation Accepts up to 6 pH calibration points Auto calibrates USA, NIST, & DIN pH buffers Displays offset & average slope Allows 1-point ORP calibration and temperature calibrationScope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains: 9625-10D refillable pH electrode with plastic body pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each)with electrode holder

€315.00*
Horiba LAQUA PH2000 starter set with device featuring integrated electrode stand, electrode, buffer solutions, power cord and user manual
Horiba LAQUA PH2000 pH-ORP bench-top laboratory meter starter set
Article number: 895830
Version: starter-set

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. The electrode stand included in the starter set can be used to hold two electrodes and adjust their height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the LAQUA PH2000 model: The PH2000 allows you to measure the pH- or ORP- valuepH-ORP wide measuring range; -2.000 to 20.000 pH  high accuracy; ± 0.003 pH  resolution: 0.1, 0.01 or 0.001 pH  continuous display of calibrated points  display of offset and slope - by segment and average up to 5 pH  calibration points ± 2000.0 mV  1-point redox calibration  automatically recognises and calibrates USA, NIST, NIST2 and DIN pH buffers  allows CUST (Custom) buffers for manual calibration  Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm) Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring device with integrated electrode standUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9625-10D refillable pH electrode with plastic body pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) with electrode holder Manufacturer part number:Meter only   PH2000 (3200896829) Starter-set   PH2000-SR (1300098880)

€735.00*
Horiba LAQUA PH2000 (double channel meter only) Product number: 895841
Horiba LAQUA PH2000 (double channel meter only)
Article number: 895841
Version: meter only

High-end laboratory measuring instrument for analytics  Dear customers, herewith we offer you our highly professional Horiba laboratory table-top measuring instrument of the 2000 series.  The LAQUA 2000 series laboratory tabletop meter has a very high-quality 5 inch display with backlighting which shows you all the important information, such as the measured value with up to three decimal places (depending on the resolution), the temperature, the date with time and much more.  The LAQUA 2000 series also offers you an adequate device memory with automatic data storage after a set time interval to document your daily measurements accurately over a long period of time. To protect the device settings from unauthorised access, they are password-protected. After your measurements, you can easily transfer all measurement data from the device to your PC via a USB cable in CSV, Excel and Pdf formats using the DAS20 software.  In order to facilitate your daily work with the device, the table measuring device visualises the correct calibration, the stable measurement as well as the electrode wear condition. The operation is intuitive because the available keys are marked with symbols and abbreviations. After the analysis, you can clean the device easily and in a time-saving manner with a damp cloth, as the surface is dirt-repellent due to its nature. The electrode stand included in the starter set can be used to hold two electrodes and adjust their height. This allows you to individually align your electrode to your container or glass for calibration and measurement. Special features of the LAQUA PH2000 model: The PH2000 allows you to measure the pH- or ORP- valuepH-ORP wide measuring range; -2.000 to 20.000 pH  high accuracy; ± 0.003 pH  resolution: 0.1, 0.01 or 0.001 pH  continuous display of calibrated points  display of offset and slope - by segment and average up to 5 pH  calibration points ± 2000.0 mV  1-point redox calibration  automatically recognises and calibrates USA, NIST, NIST2 and DIN pH buffers  allows CUST (Custom) buffers for manual calibration  Below we would like to show you in full the general functions of the Horiba LAQUA 2000 series: internal memory for up to 2000 data sets, measurement data with time and date information records and stores data in the unit memory based on a specified time interval a 4-digit password protects the meter set-up mode from unauthorised access data can be transferred to a computer and exported in the following formats CSV/Excel/PDF GLP/GMP  compliance of the instrument as data can be displayed, recorded and printed with date and time stamp on the instrument Software updates can be downloaded to the instrument Calibration reminder function, indicates that it is time to calibrate (alarm adjustable up to 90 days) Electrode holder is mounted on the meter and can hold up to 2 electrodes (rotates 360º and can be moved up and down 30cm). Electrode holder only included in the starter set. Displays measurement stability in measurement and calibration mode displays electrode condition based on calibration data smooth surface, easy cleaning RS-232/USB, therefore easy PC and printer connection and free instrument software Ergonomic design for easy viewing and operation Clearly labelled and easy-to-use ports for communication and measurement 5" digital display with backlight, shows all important measurement values and status Automatic calibration, recognises a wide range of standard solutionsadjustable switch-off time (up to 30 minutes) temperature compensation, the temperature in °C or °F is either automatically detected if a temperature sensor is connected (ATC mode) or manually entered by the user several measuring modes: Auto-Stable mode signals a stable measured value,Auto-Hold mode holds a stable measured valueReal Time mode continuously displays current readings small meter footprint of 155 x 150 mm, saves valuable space Temperature detection, easy display of sample temperature user selectable resolution, up to 3 digits Fixed and individual calibration pointsEasy navigation, navigate through the settings menu by up, down, right and left Scope of delivery: Measuring instrumentUniversal mains adapter with 6 plugs Operating instructions Starter set version additionally contains 9625-10D refillable pH electrode with plastic body pH 4, 7 and 10 buffer solutions & 3.33M KCl (1 x 250ml each) with electrode holder Manufacturer part number:Meter only   PH2000 (3200896829) Starter-set   PH2000-SR (1300098880)

€470.00*