Skip to main content Skip to search Skip to main navigation

Neomeris water softener 60

Product number: 882063
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Neomeris water softener 60"

The Neomeris Water Softener 60 was developed for households with a maximum of 6 people and can soften up to 6,000 litres per regeneration cycle with an inlet water quality of 10°dH. The Neomeris Water Softener 60 uses ion exchange technology to partially replace the ‘hardness minerals’ calcium (Ca2+) and magnesium (Mg2+) with sodium ions (Na+). This removes the limescale and produces soft water.

Product benefits at a glance:

Structure of the Neomeris water softening system 60

The Neomeris Water Softening System 60 has a cabinet housing with a removable lid. Inside the cabinet is a GRP pressure bottle filled with high-quality ion exchange resin. The cabinet housing also serves as a container for regeneration salt for brine production (saline solution) and can hold up to 70 kg of salt. The system is completed by a Clack WS 1 CI water-controlled valve mounted on the GRP pressure bottle. The control valve has a microprocessor-controlled system that is easy to operate and uses five buttons for operation. The multifunctional display with status indicator supports metric and American units of measurement. CLACK WS 1 CI is made of a sturdy, modular material without screws, reinforced with fibreglass. Thanks to a click system, the front can be easily removed, allowing for simple maintenance.

We set the CLACK WS 1 CI control valve to the factory default setting of ‘Delayed volume-controlled regeneration’ (volume control).

Volume control with the Clack WS 1 CI valve

The Clack WS 1 CI electronic water-controlled valve records soft water consumption using an integrated water meter. When the softened water flow reaches the preset volume, the regeneration phase does not start immediately, but only at night. To ensure that limescale-free water is still available even after the predefined water capacity has been reached, a reserve capacity is set up in advance as a safety factor.

Ion exchange resin produces soft water

Ion exchange resin is the main component of every water softening system. This resin contains sodium ions (Na+). When hard water (such as tap water) is passed through the resin, the calcium and magnesium ions (Ca2+ / Mg2+) contained in the water are exchanged with the sodium ions (Na+) adhering to the resin. The result is water with soft properties. The resin has a service life of over 20 years.

Neomeris water softener 60 regenerates

Once the exchange resin has exhausted its capacity and is completely saturated with calcium and magnesium ions (Ca2+ / Mg2+), the system regenerates itself using the salt tablets (saline solution) supplied. This regeneration takes place as follows: The ion exchanger must completely remove the calcium and magnesium ions (Ca2+ / Mg2+). To achieve this, the water softener automatically feeds a highly concentrated sodium chloride solution through the ion exchange resin.

During this process, the resin is enriched with sodium ions (Na+) once again. Calcium and magnesium ions (Ca2+ / Mg2+) are discharged into the waste water together with the excess salt solution via a separate drain. Resin can now be used again to soften the tap water. During regeneration, the Neomeris water softening system 60 provides untreated tap water via a built-in bypass, ensuring a continuous water supply.

Forced regeneration of the system

If there is no activity, the system automatically enters a time-controlled, forced regeneration mode on the tenth day. This protects against the formation of germs in the resin bed. This forced regeneration is a safety regeneration that only takes place if no regeneration has occurred due to quantity control, for example during holidays.

Reliably determine salt filling

Depending on the hardness and consumption of the water, one salt refill can last for approximately 3 to 4 months. It is then necessary to add new salt. The cabinet housing is protected against overflowing water by an integrated safety float valve with a buoy.

Option: Connection kit for cabinet-type water softener

You can optionally order the matching connection kit for the cabinet-type water softener. This consists of:

  • Double nipple (item no.: 882103)
  • Connection fitting (item no.: 882068)
  • 2 × 100 cm flexible hose, 1”, female thread on both ends for water softener inlet (item no.: 882069)
  • Waste water hose (item no.: 882070)
  • Hose clamp (item no.: 882071)
  • ITP Multitri = free outlet (item no.: 882072)
  • Duroval A (item no.: 400010)

Dimensions

Height 116 cm
Length 52 cm
Width 35 cm

Weight

Weight 30,5 g

Other attributes

Country of origin DE
Customs tariff number 84212100
Technical data
System Specifications
Application Drinking water
Purpose Reduction of water hardness
System capacity at 200g salting 60 m³ per 1°dH
Salt consumption per 1°dH and 1 m³ (200g salting) Factor 0.05
System capacity at 120g salting 48 m³ per 1°dH
Salt consumption per 1°dH and 1 m³ (120g salting) Factor 0.0375
Water consumption per regeneration 6 bed volumes
System connection 24V / 50 Hz / 10VA
Ambient temperature +5 / +40°C
Water temperature +5 / +30°C
Operating pressure min. / max. 2 bar / 8 bar
Humidity <60%
Salt media DIN EN 973 (food grade)
Splash-proof No
Interfering ions Iron, Manganese, Chlorine
Component Specifications
Control valve Clack WS1.00CK ECO KTW (KTW-BWGL compliant)
Regeneration type Volume- or time-controlled, fully automatic
Salt requirement per regeneration Full salting: 1.6 / 2.5 / 4 kg
Reduced salting: 0.96 / 1.5 / 2.4 kg
Flow rate Up to 3.5 m³/h (at 1 bar pressure drop)
Capacity at 10°dH* 3,200 / 5,000 / 8,000 liters
Regeneration Amount-dependent, economical in salt and water consumption
Regeneration duration Approx. 60–90 minutes (depending on system configuration)
Resin volume (optional) e.g., 8 / 12.5 / 20 liters (model-dependent)
Salt tank Integrated, cabinet design
Salt storage Approx. 25–50 kg (depending on model size)
Operating pressure 2 – 6 bar
Operating temperature 5 – 30 °C
Permissible water hardness Up to approx. 40 °dH
Water connection 1" internal thread (IG)
Wastewater connection DN 40 hose nozzle
Power supply 230 V / 50 Hz (control unit with power supply)
Certification KTW-BWGL compliant according to UBA (as of 2025)
Application Single-family homes, offices, small businesses
Dimensions (WxHxD) e.g., 320 × 1100 × 500 mm (model-dependent)
Weight (operational) Approx. 40–60 kg (depending on equipment)

* Amount of softened water produced at a water hardness of 10°dH.

Determine water hardness / Salting

Die örtlich bei Ihnen anliegende Wasserhärte können sie z.B. auf der Internetseite ihres Wasserversorgers einsehen. Wenn sie auf Nummer sicher gehen wollen, liefern wir Ihnen gerne auch das passende Wasserhärte-Testbesteck, damit sie ganz genau die Wasserhärte vor Ort bei Ihnen bestimmen können. Sie finden dieses bei uns im Shop unter Art.Nr. 400007 DUROVAL® 1 drop = 0.1 °dH Drop Count Titration Test. This test kit is already included in the complete set with item no. 400005 Water Hardness DUO Test Kit. Below you will find some sample calculations, for your reference, of the achievable volume of softened water for water hardness levels ranging from 3 °dH to 40 °dH.

Water softeners can be regenerated using either economy salting or full salting. With full salting, approximately 200 grams of salt are used per litre of softening resin for regeneration. With partial brining, however, only 120 grams are used. Regeneration using full brining fully restores the capacity. With partial brining, 80% of the softened water capacity is restored through regeneration, despite the significantly lower salt requirement. Based on your requirements, you can therefore determine the most suitable system for your needs.

Water hardness (°dH) Cabinet-type water softener 32 Cabinet-type water softener 60 Cabinet-type water softener 80
8 L Resin Full salting (L) 8 L Resin Reduced-salt (L) 12,5 L Resin Full salting (L) 12,5 L Resin Reduced-salt (L) 20 L Resin Full salting (L) 20 L Resin Reduced-salt (L)
310.6668.53316.66613.33326.66621.333
48.0006.40012.50010.00020.00016.000
56.4005.12010.0008.00016.00012.800
65.3334.2668.3336.66613.33310.666
74.5713.6577.1425.71411.4289.142
84.0003.2006.2505.00010.0008.000
93.5552.8445.5554.4448.8887.111
103.2002.5605.0004.0008.0006.400
122.6662.1334.1663.3336.6665.333
142.2851.8283.5712.8575.7144.571
162.0001.6003.1252.5005.0004.000
181.7771.4222.7772.2224.4443.555
201.6001.2802.5002.0004.0003.200
221.4541.1632.2721.8183.6362.909
241.3331.0662.0831.6663.3332.666
261.2300.9841.9231.5383.0762.461
281.1420.9131.7851.4282.8572.285
301.0660.8531.6661.3332.6662.133
321.0000.8001.5621.2502.5002.000
340.9410.7531.4701.1762.3521.882
360.8880.7111.3881.1102.2221.778
380.8420.6741.3151.0522.1051.684
400.8000.6401.2501.0002.0001.600

Note: To ensure the water softener operates in a hygienically sound manner, the ion-exchange resin must be regenerated regularly – even if little or no water has been used.

In accordance with DIN EN 806-5 and the requirements of DVGW Worksheet W 510:

The water softener must carry out a regeneration cycle at least every 72 hours (3 days), regardless of water consumption.

This so-called forced regeneration serves to prevent microbial contamination of the ion exchange resin and ensures the long-term hygienic safety of the system.