Skip to main content Skip to search Skip to main navigation

Milwaukee MW805 4-in-1 pH/EC/TDS/Temp. Combo Meter with ATC

Article number: 896147
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee MW805 4-in-1 pH/EC/TDS/Temp. Combo Meter with ATC"

This MW805 MAX pH/EC/TDS/Temp. 4-in-1 combo meter allows you to measure pH, EC (conductivity), TDS and Temp. with a single meter and one single probe.

DESIGN FEATURES
  • pH, conductivity / nutrient EC, TDS (ppt) with automatic temperature compensation
  • Selectable TDS factors from .40 to 0.8; defaulet value 0.50
  • Stability indicator prompting the user when the readings stabilize
  • Dedicated GLP key to store and recall data on system status
  • A replaceable, Amplified Combination pH/EC/TDS/Temp probe with a single 1 meter cable for easy use (MA852D/1 probe included)
  • A cloth junction on the pH sensor to reduce contamination when measuring fertilizer solutions. Gel filled for long lasting measurments
  • A light weight and portable form factor at just 260g with battery and just over 7,62cm wide
  • A large easy to read display
  • Factory calibration for Temperature and simple, highly accurate, single cell automatic, one point calibration for EC and an automatic up to 5 point calibration for pH
  • IP 67 rated rugged case built for field or lab applications
  • Specialized design for hydroponic, aquaponic, and greenhouse growers

Dimensions

Height 11,5 cm
Length 30 cm
Width 26 cm

Weight

Weight 1,58 kg

Other attributes

Brand Milwaukee
Parameter Combined Multiparameter, Conductivity and TDS, Thermometers (°C), pH
Technical specifications
pH Range: -2.00 to 20.00 pH
EC Range: 0 to 4000 µS/cm
TDS Range: 0 to 2000 ppm (mg/L) | up to 3200 ppm (mg/L) with TDS 0.80 factor
Temperature Range: -20.0 to 120.0°C / -4.0 to 248°F
pH Resolution: 0.01 pH
EC Resolution: 1 µS/cm
TDS Resolution: 1 ppm (mg/L)
Temperature Resolution: 0.1°C / 0.1°F
pH Accuracy: ±0.01
EC/TDS Accuracy: ±2% Full Scale
Temperature accuracy: ±0.5°C / ±0.9°F
Calibration pH: Automatic up to 5 - point pH, 7 Standard Calibration Buffers: pH1.68; 4.01; 6.86; 7.01; 9.18, 10.01; 12.45 and 2 Custom Buffers
Calibration EC/TDS: Single Cell Factor Calibration; 2 Standards: 84 μS/cm; 1413 µS/cm / One- point Offset: 0.00 µS/cm
Temperature Calibration: Factory Calibrated
Temperature Compensation: Automatic (ATC) from -20 to 120°C (-4 to 248°F) | Manual (MTC) from -20 to 120°C (-4 to 248°F)
Conductivity temperature coefficient: 0.00 to 6.00 % /ºC (EC & TDS only) | Default value: 1.9 %/ºC
TDS Factor: 0.40 to 0.80; default value: 0.50
Logging Memory: Up to 1,000 log records (stored in up to 100 lots) | On demand, up to 200 logs | on Stability, up to 200 logs | Interval logging, up to 1,000 logs | Parameter-Specific log storage location
PC connectivity: 1 micro USB port
Battery Type: 3x 1.5V Alkaline AA batteries (included) | Approximately 200 hours of use
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions Meter: 200 x 85 x 50 mm
Auto-off: After 10 minutes of non-use
Casing: IP67 protection level
Weight Meter: 260g
Dimensions Packaging: 305 x 280 x 115 mm
Weight Packaged: 1.44 kg
Probe Specifications: MA852D/1 Amplified pH/EC/TDS/Temp Probe (included)
Range: pH 0 to 13 | Temperature 0.0 to 60.0°C (32.0 to 140.0°F)
EC electrodes: 2x graphite
Reference: Single, Ag/AgCl
Junction: Cloth
Electrolyte (pH): Gel
Body: ABS
Connection: DIN
Cable: 1m
Skip product gallery

Ersatzteile und Zubehör

Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004) Product number: 896151
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004)
Article number: 896151
pH buffer: pH 4.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006) Product number: 896152
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006)
Article number: 896152
pH buffer: pH 6.86 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007) Product number: 896153
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007)
Article number: 896153
pH buffer: pH 7.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€43.40*
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009) Product number: 896154
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009)
Article number: 896154
pH buffer: pH 9.18 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010) Product number: 896155
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010)
Article number: 896155
pH buffer: pH 10.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee storage solution, 230ml (MA9015) Product number: 896165
Milwaukee storage solution, 230ml (MA9015)
Article number: 896165

for pH/ORP electrodes

€43.40*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€46.40*
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060) Product number: 896157
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060)
Article number: 896157
Kalibierlösung: 12880 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€53.00*
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061) Product number: 896158
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061)
Article number: 896158
Kalibierlösung: 1413 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*