Skip to main content Skip to search Skip to main navigation

Horiba LAQUAtwin Nitrate Ion (NO3-) Tester for soil in carrying case with 5 Pipettes, 3 bottles (100 mL), 2 sampling spoons, tweezers, sampling sheet B, 2 Sampling sheet holders

Article number: 895689
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Horiba LAQUAtwin Nitrate Ion (NO3-) Tester for soil in carrying case with 5 Pipettes, 3 bottles (100 mL), 2 sampling spoons, tweezers, sampling sheet B, 2 Sampling sheet holders"

The LAQUAtwin Nitrate Ion Handheld Tester (NO3-11C) included in the analysis kit is pre-set by the factory to the relevant calibration points 30PPM and 300PPM for soil analysis.

Manufacturer Part No. 3200689164  | B-742

Additional information

We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers.

To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers.

Overview of the product change

  • Change: Battery cover for enhanced safety.
  • Reason: To prevent accidental swallowing of batteries.
  • Production date: From January 2026 in Japan
  • Deliveries to EMEA distribution partners: From March 2026

As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period.

Dimensions

Height 12 cm
Length 30 cm
Width 25 cm

Weight

Weight 1,2 g

Other attributes

Applications Aquaculture and Coral, Aquariums, Beverages, Environmental, Food, Horticulture, Hydroponics, Laboratory, Schools, Water Conditioning, Water Treatment, Wine
Brand Horiba
Country of origin IT
Customs tariff number 90278930
Parameter Combined Multiparameter, Nitrate Ion (NO3-)
Quality Advanced
Technical data
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 ml (0.05 ml with Sampling Sheet B)

Measurement Range:
NO3- : 6 to 9900 ppm (mg/L) - (0.1 to 160 mmol/L) 
NO3-N : 1.4 to 2200 ppm (mg/L)
Resolution:
 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm
1000 to 9900 ppm: 100 ppm
Accuracy:
± 10% of actual value
Maximum Calibration Points: 2
Temperature Display / Resolution: 0 to 50.0 ºC (0.1 ºC)

Functions
  • Automatic Standard Recognition
  • Changeable Low and High Calibration Values
  • Temperature Compensation
  • Temperature Calibration 
  • Multiplication Compensation (0.01 to 9.90)
  • Auto Hold / Auto Stable
  • Automatic Power Off (30 mins.)
  • Low Battery Indicator
  • IP67 Water / Dust Proof
  • Replaceable Sensor
Display: Custom (Monochrome) Digital LCD with Backlight
Operating Temperature / Humidity:
5 to 40 ºC / 85% or less in relative humidity (no condensation)
Battery Life: Approx. 400 hrs. continuous use without backlight
Material: ABS epoxy body / flat glass sensor
Dimensions: 164 x 29 x 20 mm(excluding projections)
Mass: Approx. 55g (including sensor and batteries)

Accessories included
  • 30 & 300 ppm Standard Solutions (14 ml each)
  • 5 pipettes
  • 3 bottles (100 ml)
  • 2 sampling spoons
  • 1 Tweezers
  • 1 Sample bottle with cap
  • Sampling Sheet B (5 pcs)
  • Sampling Sheet Holder (sample sheet is inserted here)
  • CR2032 Batteries (2)
  • Instruction & Quick Manuals
  • Storage Case
Skip product gallery

Recommended accessories

Horiba Nitrate Ion Standard Solution 30ppm, 6 bottles, for reliable water quality calibration
Horiba 30ppm Nitrate Ion Standard Solution (Y044)
Article number: 895682

To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053535

€59.00*
Horiba 300ppm Nitrate Standard Solution, 6 bottles in a row, reliable calibration for water quality
Horiba 300ppm Nitrate Ion Standard Solution (Y042)
Article number: 895680

To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: - pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester.- Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely.- NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement.- Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm).- Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm.- TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements.- ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Manufacturer Part No. 3200053514

€59.00*
Horiba LAQUAtwin Potassium Ion (K⁺) Tester with 2 Calibration Points and Temperature Measurement (K-11) Sensor Cap On, Sensor Visible, Display On Showing Measurement.
Horiba LAQUAtwin Potassium Ion (K+) Tester with 2 calibration points and temperature measurement (K-11)
Article number: 895658

Precise Potassium Ion Measurement on the Go – Mobile, Reliable, and Easy Precise potassium ion measurement with 2-point calibration and integrated temperature display The Horiba K-11 Potassium Pocket Tester was designed to determine potassium in a wide variety of samples with high precision. Thanks to the ion-selective electrode and the digital LCD screen with backlight, the tester is perfect for mobile water quality and environmental analyses. The minimal sample volume of only 0.3 ml (0.05 ml with sampling sheet) ensures reliable results even with small sample sizes. With its 2-point calibration and automatic standard recognition, the device can be flexibly adapted to different measurement conditions. The IP67 rating for dust and water protection, along with a long battery life of up to approximately 400 hours, makes the tester highly reliable for mobile use. Technical Features for Reproducible Potassium Measurements The potassium tester covers a wide measurement range from 4 to 9,900 ppm (mg/L) and additionally displays temperatures up to 50 °C with a resolution of 0.1 °C. The integrated temperature compensation ensures stable results even under changing environmental conditions. Automatic standard recognition, adjustable calibration values, and multiplication compensation guarantee high reproducibility across different sample types. This makes the K-11 suitable for both routine and demanding analytical tasks. Why Potassium Measurement Is Important – Ideal with the Horiba K-11 Hand Tester Potassium is an essential parameter in water, environmental, agricultural, and food analysis. In water bodies, potassium content affects water quality, in soils it is a key nutrient for healthy plant growth, and in food it plays an important role for nutrition and labeling requirements. A mobile potassium hand tester enables rapid on-site analysis without time-consuming laboratory testing. Changes can be detected immediately, and decisions can be made right away. The Horiba K-11 combines this flexibility with high measurement accuracy and ease of use – ideal for fieldwork, routine checks, and scientific studies. Where Can It Be Used? Environmental Monitoring: The K-11 is a fast and precise measurement tool for environmental technicians and scientists monitoring potassium concentrations in water bodies to ensure water quality and identify contamination sources. Agriculture: The K-11 allows farmers and agronomists to measure potassium in soil. This is crucial for fertilizer application and improving plant growth. Easy evaluation of soil extracts enables precise nutrient requirement determination. Food Industry: The tester is used by quality assurance personnel to check potassium content in beverages and food. These measurements are important for product development, health assessments, and compliance with nutritional labeling requirements. Teaching, Research, and Development: By deepening the understanding of potassium’s role in biological and chemical processes, the K-11 serves researchers and educators as a useful tool for experimental studies and educational purposes. Additional information We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: From January 2026 in Japan Deliveries to EMEA distribution partners: From March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period. Frequently asked questions How long is the warranty period for HORIBA pocket testers? The warranty period is two years from delivery for commercial customers. How many measurements can be taken before the sensor needs to be replaced? This varies depending on the application, use and storage of the Horiba tester. As a rule, the sensor should be replaced after one year. How long is the warranty period for replacement sensors for pocket testers? The warranty period is 12 months after delivery for commercial customers. How do you clean the pocket tester? The pocket tester can be rinsed under water. We recommend cleaning with DI water (deionised). Tissue paper is recommended for drying after cleaning. How can the pocket tester be reset to factory settings? (e.g. in the event of an incorrect measurement result) This information can be found in the operating instructions. These can be found in the download area of the shop and on the product. Is calibration necessary before each measurement? Basically, yes. Further information can be found in the operating instructions.

€385.00*
Horiba LAQUAtwin Calcium Ion (Ca²⁺) Tester with 2 Calibration Points and Temperature Measurement (Ca-11), sensor cap on, sensor visible, display on showing measurement.
Horiba LAQUAtwin Calcium Ion (Ca2+) Tester with 2 calibration points and temperature measurement (Ca-11)
Article number: 895660

Mobile Calcium Ion Tester from Horiba with Temperature Measurement – precise, compact, robust Handheld Ca²⁺ pocket tester with 2-point calibration and temperature display – ideal for water and environmental applications The mobile Horiba LAQUAtwin calcium ion tester measures both the Ca²⁺ concentration and the temperature of a sample. Equipped with an ion-selective sensor, a digital LCD display, and a minimal sample volume of only 0.3 ml (0.05 ml when using the sampling sheet), it delivers fast and reliable measurement results. Thanks to the integrated temperature display and automatic temperature compensation, calcium values can be measured accurately even under changing environmental conditions – making the device ideal for mobile applications. Mobile calcium ion tester for precise on-site measurements With two calibration points and automatic standard recognition (150 and 2000 ppm), the device can be flexibly adapted to different measurement situations. Temperature-compensated measurement, multiplicative compensation, automatic stability and hold modes, as well as automatic shut-off ensure easy and reliable operation. The tester is dustproof and waterproof according to IP67 and offers a long battery life of approximately 400 hours. It is supplied complete with standard solutions, sampling sheets, pipette, and batteries. Why calcium measurement is important – optimal results with the Horiba handheld tester Calcium is a key parameter in water, environmental, aquaculture, and food analysis. Calcium concentration influences water hardness, biological processes, coral growth, and product quality in beverages and food. Deviations can lead to ecological, technical, or quality-related impacts. A mobile calcium handheld tester allows fast analysis directly at the point of use without complex laboratory procedures. This makes it possible to detect changes immediately and take timely action. The Horiba LAQUAtwin calcium tester combines this flexibility with high measurement accuracy, simple operation, and a robust design. Typical applications of the Horiba LAQUAtwin calcium tester Aquaculture and corals Laboratories and schools Water treatment Beverages and food Additional information We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: From January 2026 in Japan Deliveries to EMEA distribution partners: From March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period. Frequently asked questions How long is the warranty period for HORIBA pocket testers? The warranty period is two years from delivery for commercial customers. How many measurements can be taken before the sensor needs to be replaced? This varies depending on the application, use and storage of the Horiba tester. As a rule, the sensor should be replaced after one year. How long is the warranty period for replacement sensors for pocket testers? The warranty period is 12 months after delivery for commercial customers. How do you clean the pocket tester? The pocket tester can be rinsed under water. We recommend cleaning with DI water (deionised). Tissue paper is recommended for drying after cleaning. How can the pocket tester be reset to factory settings? (e.g. in the event of an incorrect measurement result) This information can be found in the operating instructions. These can be found in the download area of the shop and on the product. Is calibration necessary before each measurement? Basically, yes. Further information can be found in the operating instructions.

€385.00*
Horiba LAQUAtwin Sodium Ion (Na⁺) Tester with 2 Calibration Points and Temperature Measurement (Na-11) Close-up View, Sensor in Focus, Display Turned On Showing Readings.
Horiba LAQUAtwin Sodium Ion Tester (Na+) with 2 calibration points and temperature measurement (Na-11)
Article number: 895657

Mobile Sodium Ion Tester from Horiba with Temperature Measurement – precise and robust High-precision sodium ion tester with 2-point calibration – ideal for water and environmental analysis The Horiba LAQUAtwin Na-11 sodium ion tester was specifically designed for accurate measurement of sodium concentrations in a wide range of samples. The device enables direct on-site measurements. Its clear display shows both the Na⁺ concentration and the sample temperature in a single step, making field, laboratory, and greenhouse work significantly more efficient. Mobile sodium ion tester for precise on-site measurements Featuring 2-point calibration and automatic standard recognition (150 and 2000 ppm), the instrument can be easily adapted to different measurement requirements. The integrated temperature display and automatic temperature compensation ensure accurate results even under fluctuating environmental conditions. The robust IP67 housing is dustproof and waterproof, making the tester suitable for demanding daily use. With a battery life of approximately 400 hours, reliable long-term operation is ensured. The tester is supplied with standard solutions, sampling sheets, batteries, and matching pipettes for immediate use. Why sodium measurement matters – and why a handheld tester is the ideal solution Measuring sodium ions plays a crucial role in water, environmental, food, and agricultural analysis. Excessively high or low sodium concentrations can significantly affect water quality, soil structure, plant growth, and the quality of food products and drinking water. Regulatory limits and quality standards further require regular monitoring. A mobile sodium ion handheld tester enables fast and precise analysis directly at the point of use, without time-consuming sampling or laboratory analysis. The Horiba LAQUAtwin Na-11 combines this flexibility with high measurement accuracy and ease of use, making it ideal for routine monitoring, quality control, and research applications. Typical applications for the Horiba sodium ion tester Environmental monitoring: Measurement of sodium concentrations in surface and groundwater to assess water quality and ensure compliance with environmental standards. Food and beverage production: Testing sodium levels in food and beverages for quality assurance, product development, and regulatory compliance. Agriculture: Monitoring sodium content in irrigation water and soils to support plant health and optimize water management. Research & development: Use in laboratories for experimental studies on sodium ion behavior under varying conditions. Education: Utilized in schools and universities to demonstrate the use of ion-selective electrodes in analytical chemistry. Additional information We would like to inform you of an upcoming product update for the LAQUAtwin handheld analysers. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: From January 2026 in Japan Deliveries to EMEA distribution partners: From March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition period. Frequently asked questions How long is the warranty period for HORIBA pocket testers? The warranty period is two years from delivery for commercial customers. How many measurements can be taken before the sensor needs to be replaced? This varies depending on the application, use and storage of the Horiba tester. As a rule, the sensor should be replaced after one year. How long is the warranty period for replacement sensors for pocket testers? The warranty period is 12 months after delivery for commercial customers. How do you clean the pocket tester? The pocket tester can be rinsed under water. We recommend cleaning with DI water (deionised). Tissue paper is recommended for drying after cleaning. How can the pocket tester be reset to factory settings? (e.g. in the event of an incorrect measurement result) This information can be found in the operating instructions. These can be found in the download area of the shop and on the product. Is calibration necessary before each measurement? Basically, yes. Further information can be found in the operating instructions.

€385.00*