Skip to main content Skip to search Skip to main navigation

Milwaukee MW302 PRO portable EC meter

Article number: 895566
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee MW302 PRO portable EC meter"

Portable conductivity meter for higher conductivity ranges with automatic temperature compensation.

Milwaukee MW302 PRO portable conductivity meter for high measurement ranges

The Milwaukee MW302 PRO is designed for conductivity measurements in applications involving elevated salt and nutrient concentrations. Thanks to its extended measurement range, the device is particularly well-suited for agriculture, hydroponics, and water treatment, as well as numerous other applications in laboratories and food production.

Measuring electrical conductivity provides important information regarding the concentration of dissolved salts in a solution. In hydroponic systems, the MW302 PRO aids in monitoring nutrient solutions, allowing fertilizer concentrations to be controlled and adjusted as needed. Conductivity measurement is also useful in agriculture for assessing nutrient levels and irrigation solutions.

For ease of use, the meter features automatic temperature compensation. This accounts for temperature fluctuations during measurement and improves the comparability of results. Its compact design allows for flexible use directly on-site.

The MW302 PRO comes complete with a suitable conductivity probe and calibration solution, ensuring a quick and easy start to conductivity measurement.

Technical Specifications

  • Measurement parameter: EC (Electrical Conductivity)
  • Measurement range: EC: 0.0 to 10.0 mS/cm
  • Resolution: 0.1 mS/cm
  • Accuracy: ±2% of full scale at 25°C

Key Benefits at a Glance

  • For conductivity measurements in higher ranges
  • Automatic temperature compensation
  • Compact and portable design
  • Includes conductivity probe and calibration solution
  • Long battery life for mobile applications

Typical Applications

  • Agriculture
  • Hydroponics and soilless cultivation
  • Greenhouse applications
  • Water treatment
  • Food production
  • Water analysis

Scope of Delivery

  • Milwaukee MW302 PRO meter
  • SE520 conductivity probe
  • 1413 µS/cm calibration solution
  • 9V battery
  • User manual

Frequently Asked Questions

The MW302 is a portable high-range (EC High) conductivity meter with automatic temperature compensation.

Measurement parameter: EC (Electrical Conductivity)

Measurement range: EC: 0.0 to 10.0 mS/cm

It is particularly suitable for water with higher concentrations of dissolved substances.

Yes, the device is portable and delivers quick results.

Yes, operation is straightforward and easy to understand.

The large display ensures a clear and easy-to-read readout.

No, the readings are displayed within a few seconds.

Yes, it is suitable for frequent use in both daily life and professional settings.

You gain immediate clarity and can react promptly if necessary.

This meter was developed for agricultural and hydroponic applications and is also ideally suited for use in the food industry, laboratories, and water treatment.

Dimensions

Height 67 mm
Length 21,2 cm
Width 14,5 cm

Weight

Weight 440 g

Other attributes

Applications Food, Laboratory, Water Treatment
Brand Milwaukee
Country of origin RO
Customs tariff number 38221900
Parameter Conductivity and TDS
Quality Basic
Technical specifications
Range: 0.0 to 10.0 mS/cm
Resolution: 0.1 mS/cm
Accuracy: ±2% Full Scale @ 25ºC
Temperature Compensation: Automatic, from 5 to 50ºC / 41F to 122F
Conductivity Probe: SE520 (included)
Starter Calibration Solution MI0031B, 1413 uS/cm (included)
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Battery Type: 1 x 9V alkaline (included)
Battery Life: Approx. 300 hours of continuous use
Meter Dimensions: 143 x 80 x 32 mm
Meter Weight: 0.23 kg
Packaged Dimensions: 212 x 145 x 67 mm
Packaged Weight: 0.44 kg
Skip product gallery

Ersatzteile und Zubehör

Milwaukee M10032B TDS calibration solution pouch front, 25 pouches of 20 ml each, calibration solution 1382 ppm for TDS measurement, practical single portions for accurate calibration
Milwaukee M10032B 1382 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895532

Die M10032B ist eine präzise TDS-Kalibrierlösung (1382 ppm) im Einwegbeutel. Perfekt für portable und Laborgeräte, wenn eine schnelle und saubere Kalibrierung erforderlich ist. Häufige Fragen Wofür brauche ich eine Puffer- oder Kalibrierlösung? Damit stellen Sie Ihr Messgerät richtig ein und sorgen für verlässliche Messwerte. Wie oft sollte ich mein Messgerät kalibrieren? Das hängt von der Nutzung ab. Bei häufiger Nutzung empfiehlt sich eine regelmäßige Kalibrierung. Passt die Milwaukee Kalibrierlösung auch zu anderen Messgeräten? In vielen Fällen ja, wenn der gleiche Messbereich verwendet wird. Kann ich eine geöffnete Lösung mehrfach verwenden? Ja, solange sie sauber bleibt und korrekt gelagert wird. Wie lagere ich Puffer- und Kalibrierlösungen richtig? Am besten kühl, trocken und gut verschlossen lagern. Woran erkenne ich, dass ich neu kalibrieren sollte? Wenn Messwerte ungewöhnlich wirken oder diese sich deutlich verändern.

€69.40*
Milwaukee M10031B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml visible, calibration solution 1413 µS/cm, practical single portions for calibration, Milwaukee solution for conductivity meters
Milwaukee M10031B 1413µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895531

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10038B 6.44 ppt TDS calibration solution sachet front with packaging in the background, 25 individual sachets of 20 ml each, calibration solution for TDS measuring devices, practical portion sachets
Milwaukee M10038B 6.44 ppt TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895533

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060) Product number: 896157
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060)
Article number: 896157
Kalibierlösung: 12880 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€53.00*
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061) Product number: 896158
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061)
Article number: 896158
Kalibierlösung: 1413 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee 1382 ppm TDS Calibration Solution 230ml (MA9062) Product number: 896156
Milwaukee 1382 ppm TDS Calibration Solution 230ml (MA9062)
Article number: 896156

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€53.00*