Skip to main content Skip to search Skip to main navigation

Milwaukee MW803 waterproof low range pH / EC / TDS /Temperature Tester with replaceable probe

Article number: 895518
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee MW803 waterproof low range pH / EC / TDS /Temperature Tester with replaceable probe"

Das Milwaukee MW803 ist ein kompaktes, wasserdichtes All-in-One-Messgerät für pH, Leitfähigkeit, TDS und Temperatur. Speziell für Messungen im niedrigen Leitfähigkeitsbereich entwickelt, eignet es sich optimal für Hydroponik, Trinkwasseranalysen und Anwendungen mit geringer Salzkonzentration. Dank automatischer Temperaturkompensation, austauschbarer Sonde und einfacher Handhabung bietet der MW803 höchste Zuverlässigkeit auch im mobilen Einsatz.

Dimensions

Height 25,5 cm
Length 6,6 cm
Width 4,7 cm

Weight

Weight 120 g

Other attributes

Applications Aquariums, Beverages, Food, Horticulture, Laboratory, Wine
Brand Milwaukee
Country of origin RO
Customs tariff number 90278930
Parameter Combined Multiparameter, Conductivity and TDS, pH
Quality Advanced
Specifications
Measuring ranges
pH measuring range: 0.00 to 14.00 pH 
Conductivity measuring range: 0 to 3999 µS/cm
TDS measuring range: 0 to 2000 ppm
Temperature range: 0.0 to 50.0 °C (32.0 to 122.0 °F)
Measurement resolution
pH Resolution: 0.01 pH
Conductivity Resolution: 1 µS/cm
TDS resolution: 1 ppm
Temperature resolution: 0.1 °C / 0.1 °F
Measurement accuracy (@25°C / 77°F)
pH accuracy: 0.05 pH
Conductivity accuracy: ± 2% FS (full scale)
TDS accuracy: ± 2% FS (full scale)
Temperature accuracy: ±0.5 °C (±1 °F)
TDS factor
0.45 to 1.00 (CONV)
Temperature compensation
Automatic from ß=0.0 to 2.4%/ °C
Calibration
Automatic, 1 point for conductivity and 1 or 2 points for pH
General
Electrode: replaceable (MI60P)
Environment: 0 to 50 °C / 32 to 122 °F; max. RH 100%
Battery type: 4 x 1.5 V alkaline (supplied)
Battery life: approx. 100 hours operating time
Dimensions: 200mm x diameter 38mm
Weight: approx. 100 g
Skip product gallery

Ersatzelektroden und Zubehör

Milwaukee M10004B pH 4.01 calibration solution, front of bag with product name and volume
Milwaukee M10004B pH 4.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895526

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10007B pH 7.01 calibration solution bag front, 25 bags of 20 ml visible, calibration solution pH 7.01 for accurate measurements
Milwaukee M10007B pH 7.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895527

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10010B pH 10.01 calibration solution bag front, 25 bags of 20 ml each, calibration solution pH 10.01 for precise pH measurement, Milwaukee pH 10 calibration solution in a practical bag, pH 10 reference solution for calibrating measuring devices
Milwaukee M10010B pH 10.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895528

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10016B Electrode Cleaning Solution Bag Front, 25 bags of 20 ml each, cleaning solution for pH electrodes, practical single-dose bags, Milwaukee cleaning solution for electrode maintenance
Milwaukee M10016B Electrode Cleaning Solution in a sachet, 25 sachets á 20ml
Article number: 895529

Die M10016B Reinigungslösung von Milwaukee sorgt für eine gründliche Pflege von Elektroden. Jeder Beutel enthält 20 ml und bietet eine hygienische, frische Anwendung, um die Lebensdauer und Genauigkeit der Messgeräte zu erhalten.

€76.52*
Milwaukee M10030B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml each, calibration solution 12880 µS/cm for conductivity measurement, practical individual bags for accurate calibration, Milwaukee calibration solution for conductivity meters
Milwaukee M10030B 12880 µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895530

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10031B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml visible, calibration solution 1413 µS/cm, practical single portions for calibration, Milwaukee solution for conductivity meters
Milwaukee M10031B 1413µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895531

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10032B TDS calibration solution pouch front, 25 pouches of 20 ml each, calibration solution 1382 ppm for TDS measurement, practical single portions for accurate calibration
Milwaukee M10032B 1382 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895532

Die M10032B ist eine präzise TDS-Kalibrierlösung (1382 ppm) im Einwegbeutel. Perfekt für portable und Laborgeräte, wenn eine schnelle und saubere Kalibrierung erforderlich ist. Häufige Fragen Wofür brauche ich eine Puffer- oder Kalibrierlösung? Damit stellen Sie Ihr Messgerät richtig ein und sorgen für verlässliche Messwerte. Wie oft sollte ich mein Messgerät kalibrieren? Das hängt von der Nutzung ab. Bei häufiger Nutzung empfiehlt sich eine regelmäßige Kalibrierung. Passt die Milwaukee Kalibrierlösung auch zu anderen Messgeräten? In vielen Fällen ja, wenn der gleiche Messbereich verwendet wird. Kann ich eine geöffnete Lösung mehrfach verwenden? Ja, solange sie sauber bleibt und korrekt gelagert wird. Wie lagere ich Puffer- und Kalibrierlösungen richtig? Am besten kühl, trocken und gut verschlossen lagern. Woran erkenne ich, dass ich neu kalibrieren sollte? Wenn Messwerte ungewöhnlich wirken oder diese sich deutlich verändern.

€82.59*
Milwaukee M10038B 6.44 ppt TDS calibration solution sachet front with packaging in the background, 25 individual sachets of 20 ml each, calibration solution for TDS measuring devices, practical portion sachets
Milwaukee M10038B 6.44 ppt TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895533

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004) Product number: 896151
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004)
Article number: 896151
pH buffer: pH 4.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006) Product number: 896152
Milwaukee pH 6.86 Calibration Buffer Solution 230ml (MA9006)
Article number: 896152
pH buffer: pH 6.86 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007) Product number: 896153
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007)
Article number: 896153
pH buffer: pH 7.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€51.65*
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009) Product number: 896154
Milwaukee pH 9.18 Calibration Buffer Solution 230ml (MA9009)
Article number: 896154
pH buffer: pH 9.18 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010) Product number: 896155
Milwaukee pH 10.01 Calibration Buffer Solution 230ml (MA9010)
Article number: 896155
pH buffer: pH 10.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee storage solution, 230ml (MA9015) Product number: 896165
Milwaukee storage solution, 230ml (MA9015)
Article number: 896165

for pH/ORP electrodes

€51.65*
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060) Product number: 896157
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060)
Article number: 896157
Kalibierlösung: 12880 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€63.07*
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061) Product number: 896158
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061)
Article number: 896158
Kalibierlösung: 1413 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee 1382 ppm TDS Calibration Solution 230ml (MA9062) Product number: 896156
Milwaukee 1382 ppm TDS Calibration Solution 230ml (MA9062)
Article number: 896156

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€63.07*