Milwaukee EC60 waterproof Conductivity (High Range), TDS and Temperature Tester with replaceable probe

Article number: 895515
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee EC60 waterproof Conductivity (High Range), TDS and Temperature Tester with replaceable probe"

Waterproof multifunction meter for measuring conductivity, TDS, and temperature in high ranges. Features automatic temperature compensation, a replaceable probe, and a rugged design suitable for applications in aquaculture, industry, water treatment, and food production.

Milwaukee EC60 waterproof high-range conductivity, TDS, and temperature meter – Reliable water quality monitoring – anywhere you need it

The Milwaukee EC60 was developed for applications requiring reliable measurement of higher conductivity and TDS levels. This compact meter combines conductivity, total dissolved solids (TDS), and temperature measurements into a single device, making it suitable for a wide range of applications.

Its extended measurement range makes the EC60 particularly well-suited for samples with high salt or mineral concentrations. Automatic temperature compensation accounts for temperature fluctuations during measurement, ensuring consistent results.

Its rugged, waterproof design allows for both indoor and outdoor use. Automatic 1-point calibration ensures quick setup and easy maintenance. The replaceable probe further extends the meter's service life and helps reduce long-term costs.

By simultaneously measuring conductivity, TDS, and temperature, the Milwaukee EC60 offers a practical solution for users who need to monitor multiple water parameters with a single device.

Technical Specifications

  • Measurement parameters: Conductivity (High range) | TDS (Total Dissolved Solids) | Temperature
  • Measurement range: 0.00 to 20.00 mS/cm | 0.00 to 10.00 ppt (= 10,000 ppm) TDS | 0.0 to 60.0 °C
  • Resolution: 0.01 mS/cm / 0.01 ppt / 0.1 °C / 0.1 °F
  • Temperature compensation: Automatic

Key benefits at a glance

  • Designed for higher conductivity and TDS ranges
  • Waterproof housing for daily use
  • Automatic temperature compensation
  • Replaceable probe for extended service life
  • Compact and user-friendly design

Typical applications

  • Aquaculture and coral farming
  • Beverage industry
  • Food production
  • Swimming pool technology
  • Hydroponics
  • Water treatment

Frequently Asked Questions

Yes, this compact device is ideal for quick measurements on the go.

It is suitable for aquariums, hydroponics, swimming pools and many other areas.

No, the tester measures several key water parameters in a single device. It combines EC, TDS and temperature measurements in a waterproof unit and offers automatic temperature compensation.

Measurement parameters: Conductivity (high range) | TDS (total dissolved solids) | Temperature

Measuring range: 0.00 to 20.00 mS/cm | 0.00 to 10.00 ppt (= 10,000 ppm) TDS | 0.0 to 60.0 °C

Measurements can be taken in just a few simple steps and the display is easy to read.

The probe can be replaced without having to replace the entire device.

Yes, the waterproof housing is designed for damp working environments.

The values are shown on the display within a few seconds.

Dimensions

Height 25,5 cm
Length 6,6 cm
Width 4,7 cm

Weight

Weight 120 g

Other attributes

Applications Aquaculture and Coral, Aquariums, Beverages, Food, Hydroponics, Pools, Schools
Brand Milwaukee
Country of origin RO
Customs tariff number 90278930
Parameter Combined Multiparameter, Conductivity and TDS
Quality Advanced
Specifications
Measuring ranges
Conductivity measuring range: 0.00 to 20.00 mS/cm
TDS measuring range: 0.00 to 10.00 ppt
Temperature range: 0.0 to 60.0 °C (23 to 140 °F)
Measurement resolution
Conductivity Resolution: 0.01 mS/cm
TDS resolution: 0.01 ppt
Temperature resolution: 0.1 °C / 0.1 °F
Measurement accuracy (@25°C / 77°F)
Conductivity accuracy: ± 2% FS (full scale)
TDS accuracy: ± 2% FS (full scale)
Temperature accuracy: ±0.5 °C (±1 °F)
Typical EMC deviation
±2% conductivity (full scale)
±2% TDS (full scale)
±0.5 °C / ±1 °F (full scale)
Temperature compensation
Automatic from ß=0.0 to 2.4%/ °C
Calibration
Automatic, 1 point
General
Electrode: replaceable (MI59P)
Environment: 0 to 50 °C / 32 to 122 °F; max. RH 100%
Battery type: 4 x 1.5 V alkaline (supplied)
Battery life: approx. 100 hours operating time
Dimensions: 200mm x diameter 38mm
Weight: approx. 100 g
Skip product gallery

Ersatzelektroden und Zubehör

Milwaukee M10030B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml each, calibration solution 12880 µS/cm for conductivity measurement, practical individual bags for accurate calibration, Milwaukee calibration solution for conductivity meters
Milwaukee M10030B 12880 µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895530

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10031B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml visible, calibration solution 1413 µS/cm, practical single portions for calibration, Milwaukee solution for conductivity meters
Milwaukee M10031B 1413µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895531

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee M10032B TDS calibration solution pouch front, 25 pouches of 20 ml each, calibration solution 1382 ppm for TDS measurement, practical single portions for accurate calibration
Milwaukee M10032B 1382 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895532

Die M10032B ist eine präzise TDS-Kalibrierlösung (1382 ppm) im Einwegbeutel. Perfekt für portable und Laborgeräte, wenn eine schnelle und saubere Kalibrierung erforderlich ist. Häufige Fragen Wofür brauche ich eine Puffer- oder Kalibrierlösung? Damit stellen Sie Ihr Messgerät richtig ein und sorgen für verlässliche Messwerte. Wie oft sollte ich mein Messgerät kalibrieren? Das hängt von der Nutzung ab. Bei häufiger Nutzung empfiehlt sich eine regelmäßige Kalibrierung. Passt die Milwaukee Kalibrierlösung auch zu anderen Messgeräten? In vielen Fällen ja, wenn der gleiche Messbereich verwendet wird. Kann ich eine geöffnete Lösung mehrfach verwenden? Ja, solange sie sauber bleibt und korrekt gelagert wird. Wie lagere ich Puffer- und Kalibrierlösungen richtig? Am besten kühl, trocken und gut verschlossen lagern. Woran erkenne ich, dass ich neu kalibrieren sollte? Wenn Messwerte ungewöhnlich wirken oder diese sich deutlich verändern.

€82.59*
Milwaukee M10038B 6.44 ppt TDS calibration solution sachet front with packaging in the background, 25 individual sachets of 20 ml each, calibration solution for TDS measuring devices, practical portion sachets
Milwaukee M10038B 6.44 ppt TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895533

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€82.59*
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060) Product number: 896157
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060)
Article number: 896157
Kalibierlösung: 12880 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€63.07*
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061) Product number: 896158
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061)
Article number: 896158
Kalibierlösung: 1413 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€55.22*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€55.22*