Skip to main content Skip to search Skip to main navigation

Testomat® EVO TH CAL

Product number: 100712
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Testomat® EVO TH CAL"

Features and Equipment

Optical water detection when filling the measuring chamber ensures precise dosing. Additionally, the device features automatic venting of the indicator line, an integrated self-test, and a multilingual menu. Measurement data and messages/alarms are logged via an integrated SD card or optional SDHC card. Recorded values and alarms can be transmitted for external processing via an analog 0/4–20 mA output or the RS232 interface.

Applications of the Testomat EVO TH CAL

  • Monitoring hardness in water treatment systems
  • Water hardness measurement in drinking water systems
  • Fully automatic hardness measurement in industrial boilers
  • Process water monitoring

Continuous monitoring of water hardness enables reliable process control in water treatment, drinking water, and industrial systems. Scale deposits, corrosion, and energy losses are reduced, legal limits are safely maintained, and equipment lifespan is extended. Deviations in water hardness are detected early, improving operational safety, product quality, and efficiency.

Benefits of the Testomat EVO TH CAL in Daily Operation

The Testomat EVO TH CAL features minimal water and indicator consumption as well as simple data management. With a freely programmable password, external reset and acknowledgment inputs, and the ability to adapt to temporarily low water pressure, the device is suitable for demanding environments.

Dimensions

Height 48 cm
Length 28 cm
Width 38 cm

Weight

Weight 9,12 kg

Other attributes

Country of origin EU
Customs tariff number 90278990
Technical specifications
Supply voltage: switching power supply 100-240 VAC, 100-353 VDC
Power consumption: max. 30 VA
Protection class: I
Protection: IP 44
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa (after removal of the valve body)
Weight: approx. 9,0 kg
Menu Language: German, English, French, Dutch, Spanish, Turkish, Chinese, Czech, Russian (others on request)
Measuring range: Water hardness: 0.89 - 448 ppm

Skip product gallery

We recommend our indicators, as well as the following accessories

Testomat® Indicator TH2005 500ml, bottle with product label and measuring range 0.05–0.50 °dH, water quality test
Testomat® indicator TH 2005, 500ml
Product number: 152005

Testomat Indicator TH2005 – Residual Hardness Measurement Original indicator for precise determination of residual hardness in water The Testomat Indicator TH2005 from Heyl, 500 ml, is an original measurement solution for determining residual hardness in water. The indicator ensures high measurement accuracy and reliability for daily use. Measurements are provided in standardized units (°dH, °f, ppm CaCO₃, and mmol/l). Order online now and benefit from a 3% discount in the online shop on Heyl products. The indicator is specifically designed for residual hardness monitoring in water treatment. It is suitable for continuous process control and stable water quality. Advantages of the Original Testomat TH2005 Indicator The Testomat Indicator TH2005 offers a wide range of benefits for reliable residual hardness monitoring in demanding applications: High accuracy in the low range: Specifically designed for precise determination of very low residual hardness from 0.05 to 0.50 °dH. Reliable color reaction: Clear and reproducible color changes allow secure monitoring of residual hardness. Versatile display units: Measurement in °dH, °f, ppm CaCO₃, and mmol/l – ideal for international and industrial applications. Optimal device compatibility: Precisely calibrated for the Testomat 2000 series, the new Testomat Limit from Heyl, and other compatible Testomat devices. Suitable for continuous operation: Designed for ongoing process control in water treatment, industry, and supply technology. Heyl original quality: Ensures proper device operation and retention of warranty and guarantee claims. Where can the TH2005 indicator be used? It is suitable for water treatment, industry, and supply technology. Compatible with the following devices: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomat EVO TH Testomat Limit Which measurement ranges does the TH2005 indicator cover? 0.05–0.50 °dH with 0.01 resolution 0.09–0.89 °f 0.89–8.93 ppm CaCO₃ 0.01–0.09 mmol/l

€124.00*
Testomat Indicator TH2025 500ml Front view with white label, 500 ml bottle for measuring residual hardness in water
Testomat® indicator TH 2025 500ml
Product number: 152025

Testomat Indicator TH2025 – for Determining Residual Hardness Precise Residual Hardness Measurement with the TH 2025 for Testomat 2000 and Testomat Limit The Testomat Indicator TH2025 from Heyl is a chemical reagent solution for precise determination of residual hardness. It measures in various units (°dH, °f, ppm CaCO₃, and mmoI/I). Enjoy a 3% discount on Heyl products when ordering online in our HeylNeomeris Shop. With the TH2025 indicator, you can determine residual hardness in the range of 0.25 to 2.50 °dH. The 500 ml bottle provides a convenient dosing solution that can be used directly in the measuring device without any complex preparation. Where can the TH2025 Indicator be used? The indicator is suitable for: Testomat 2000 Testomat 2000 CAL Testomat 2000 DUO Testomat 2000 V Testomat 2000 self clean Testomat ECO Testomat ECO-PLUS Testomar EVO TH Testomat Limit What are the measurement ranges? 0.25–2.50 °dH, with a resolution of 0.05 0.45–4.48 °f, with a resolution of 0.10 4.48–44.8 ppm CaCO₃, with a resolution of 0.9 0.04–0.45 mmoI/I, with a resolution of 0.01

€124.00*
Testomat® Indicator TH2050 500 ml for testing water hardness
Testomat® indicator TH2050 500ml
Product number: 152050

The 500 ml bottle of original Testomat® indicator TH 2050 for the limit value 0.5 - 5.0 °dH only for Testomat® EVO TH and Testomat® LAB TH.

€128.16*
500ml bottle of Testomat® TH2100 with product label
Testomat® indicator TH 2100 500ml
Product number: 152100

Testomat Indicator TH2100 for Determining Elevated Residual Hardness Indicator solution for precise monitoring of residual hardness in the higher limit range 1.00–10.00 °dH The Testomat Indicator TH2100 from Heyl, 500 ml bottle, is an original indicator solution for determining residual hardness in the higher hardness range of 1.00–10.00 °dH in water treatment systems. The bottles are designed for use in Testomat devices and enable continuous and reliable monitoring. The TH2100 indicator is specifically designed for higher residual hardness levels. It supports safe process control in industrial and commercial water treatment systems. What measurement ranges does the TH2100 indicator cover? 1.00–10.00 °dH, resolution 0.20 1.79–17.9 °f, resolution 0.40 17.9–179 ppm CaCO₃, resolution 3.8 0.18–1.79 mmoI/I, resolution 0.04 Which Heyl Testomat devices is the indicator suitable for? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit

€128.16*
Testomat® indicator TH2250 500 ml bottle for measuring water hardness, clearly legible label
Testomat® indicator TH 2250 500ml
Product number: 152250

Original Indicator Testomat Indicator TH2250 in the 500 ml Bottle from Heyl Precise Residual Hardness Measurement for Testomats The Testomat Indicator TH2250, 500 ml bottle, measures residual hardness in water samples and is suitable for use in our measuring devices Testomat 2000, Testomat EVO, and the new limit measuring device Testomat Limit. The measuring range is 2.50–25.00 °dH with a resolution of 0.50. Thanks to precise measurements, it supports compliance with quality standards in industrial water treatment. It is designed for long service life, minimizing maintenance and downtime. The TH2250 indicator allows reliable, automatic determination of residual hardness in water. What limit values can be measured with the TH2250? 2.50–25.00 °dH, resolution 0.50 4.48–44.8 °f, resolution 0.40 44.8–448 ppm CaCO₃, resolution 3.8 0.45–4.48 mmoI/I, resolution 0.04 Where can the indicator be used? The indicators are suitable for: Testomat 2000® Testomat 2000® CAL Testomat 2000® DUO Testomat 2000® V Testomat 2000® self clean Testomat ECO® Testomat ECO®-Plus Testomat® EVO TH Testomat Limit

€128.16*