Skip to main content Skip to search Skip to main navigation

Milwaukee MW106 MAX Waterproof pH / ORP / Temp Portable Meter

Article number: 895558
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee MW106 MAX Waterproof pH / ORP / Temp Portable Meter"

The MW106 MAX meter combines all the features of a benchtop meter in an IP67 portable meter.
The meter is equipped with a range of new diagnostic functions that improve the reliability of pH measurement.

Hand carrying case
Each meter is supplied in a hard carrying case, ideal for on-site measurements.

Dimensions

Height 11,5 cm
Length 30,5 cm
Width 28 cm

Weight

Weight 1,22 kg

Other attributes

Brand Milwaukee
Country of origin RO
Customs tariff number 38221900
Parameter Combined Multiparameter, ORP, Thermometers (°C), pH
Quality Advanced
Technical specifications
pH Meter Range*: -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Electrode Range: 0 to 12 pH 
ORP Range: ±2000.0mV 
Temp. Range Meter: -20.0 to 120.00°C (-4.0 to 248.0°F)
Temp. Range Electrode: -5 to 70°C (23 to 158°F)
Resolution: 0.01 pH / .001 pH 
Resolution: 0.1mV
Resolution: 0.1°C / 0.1°F
Accuracy*: ±0.01 pH / ±0.002 pH @ 25°C / 77°F
Accuracy Electrode*: ±0.02 pH (0 to 12 pH range) 
Accuracy: ±1mV
Accuracy: ±0.5°C (±1°C outside) | ±1°F (±2°F outside)
pH Calibration: up to 5 point automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and 2 custom buffers 
Temperature Compensation*: Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual (without probe)
pH electrode: MA906BR/1 amplified pH/temperature probe (supplied)
Temperature probe: Built-in temperature sensor
Logging: Maximum 1,000 samples / on demand, 200 samples on stability 200 samples / interval logging, 1000
PC Connectivity: 1 micro USB port
Impedance: 10 Ohm
Battery type: 3 X 1.5V alkaline AA (included)
Battery life: Approx. 200 hours of use
Auto-off: Selectable 5, 10, 30, 60 min. or off
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions: 200 x 85 x 50 mm (7.9 x 3.3 x 2.0 inches)
Casing: IP67
Weight: .26 kg / 0.58 lbs (with battery)
Warranty: 2 years 

*Limits will be reduced to actual sensor limits
Skip product gallery

Spare parts and accessories

Milwaukee M10004B pH 4.01 calibration solution, front of bag with product name and volume
Milwaukee M10004B pH 4.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895526

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10007B pH 7.01 calibration solution bag front, 25 bags of 20 ml visible, calibration solution pH 7.01 for accurate measurements
Milwaukee M10007B pH 7.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895527

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10010B pH 10.01 calibration solution bag front, 25 bags of 20 ml each, calibration solution pH 10.01 for precise pH measurement, Milwaukee pH 10 calibration solution in a practical bag, pH 10 reference solution for calibrating measuring devices
Milwaukee M10010B pH 10.01 calibration solution in a sachet, 25 sachets á 20ml
Article number: 895528

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004) Product number: 896151
Milwaukee pH 4.01 Calibration Buffer Solution 230ml (MA9004)
Article number: 896151
pH buffer: pH 4.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007) Product number: 896153
Milwaukee pH 7.01 Calibration Buffer Solution 230ml (MA9007)
Article number: 896153
pH buffer: pH 7.01 (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€43.40*
Milwaukee storage solution, 230ml (MA9015) Product number: 896165
Milwaukee storage solution, 230ml (MA9015)
Article number: 896165

for pH/ORP electrodes

€43.40*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€46.40*