Skip to main content Skip to search Skip to main navigation

Milwaukee T76 waterproof high range Total Dissolved Solids Pen (TDS) with automatic temperature compensation (ATC) and replaceable probe

Article number: 895511
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee T76 waterproof high range Total Dissolved Solids Pen (TDS) with automatic temperature compensation (ATC) and replaceable probe"

Waterproof TDS meter for measuring dissolved solids in the high range. The Milwaukee T76 features automatic temperature compensation, a replaceable probe, and simple single-point calibration.

Milwaukee T76 waterproof TDS meter for dissolved solids with automatic temperature compensation and replaceable probe

The Milwaukee T76 is a waterproof TDS meter designed to measure Total Dissolved Solids (TDS) in water samples. Unlike meters designed for lower TDS ranges, the T76 is particularly well-suited for applications involving higher concentrations of dissolved substances, offering reliable water quality monitoring in demanding environments.

Automatic temperature compensation (ATC) automatically adjusts for temperature-related fluctuations during measurement. This ensures consistent and reliable results, even amidst changing ambient conditions or varying sample temperatures.

A key advantage of the Milwaukee T76 is its replaceable probe. If the sensor wears out or performance declines, the electrode can be replaced without needing to discard the entire unit. This significantly reduces maintenance costs and extends the device's service life.

Manual single-point calibration allows for easy adjustment to specific measurement requirements. Its compact design ensures a comfortable grip, making the device suitable for both portable use and regular operation in technical facilities or laboratory settings.

The waterproof housing protects the meter during use in damp environments, ensuring reliable operation under challenging conditions. Ease of use and robust construction make the Milwaukee T76 a practical solution for users who need to precisely monitor higher TDS levels.

Technical Specifications

  • Measurement parameter: Total Dissolved Solids (TDS)
  • Measurement range: 0 to 9990 ppm (mg/L)
  • Resolution: 10 ppm (mg/L)
  • Accuracy: EC: ±2% of full scale
  • Temperature compensation: Automatic, 0 to 50°C (32 to 122°F)

Advantages

  • Waterproof housing
  • Suitable for high-range TDS measurements
  • Replaceable probe
  • Rugged design for demanding operating conditions

Typical Applications

  • Water treatment
  • Process water monitoring
  • Aquariums
  • Environmental analysis
  • Laboratory applications

Scope of Delivery

  • Milwaukee T76 TDS meter
  • Batteries
  • User manual

Frequently Asked Questions

Yes, it displays the amount of dissolved substances in the water directly.

Yes, it is ideal for aquariums, pools, water treatment, and similar applications.

No, automatic temperature compensation ensures stable results.

A simple 1-point calibration—performed occasionally depending on usage—is sufficient.

It can be easily cleaned or replaced if necessary.

Yes, it is waterproof and suitable for outdoor use.

Yes—simply dip it in, read the result, and you're done; it’s very straightforward.

Dimensions

Height 25,5 cm
Length 6,6 cm
Width 4,7 cm

Weight

Weight 100 g

Other attributes

Applications Aquaculture and Coral, Laboratory, Pools, Schools, Water Conditioning
Brand Milwaukee
Country of origin RO
Customs tariff number 90278930
Parameter Conductivity and TDS
Quality Basic
Specifications
Measuring range
TDS measuring range: 0 to 9990 ppm (mg/l)
Measurement resolution
TDS Resolution: 10 ppm (mg/l)
Measurement accuracy (@20°C / 68°F)
TDS Accuracy: ± 2% FS (full scale)
Typical EMC deviation
±2% TDS (full scale)
Temperature compensation
Automatic from 0 to 50 °C with ß=2%/ °C
TDS Factor
0.5
Calibration
Manual, 1 point through trimmer
General
Electrode: replaceable (MA73076)
Environment: 0 to 50 °C / 32 to 122 °F; max. RH 100%
Battery type: 3 x 1.5 V alkaline (supplied)
Battery life: approx. 250 hours operating time
Dimensions: 165mm x diameter 30mm
Weight: approx. 80 g
Skip product gallery

Ersatzteile und Zubehör

Milwaukee M10030B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml each, calibration solution 12880 µS/cm for conductivity measurement, practical individual bags for accurate calibration, Milwaukee calibration solution for conductivity meters
Milwaukee M10030B 12880 µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895530

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10031B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml visible, calibration solution 1413 µS/cm, practical single portions for calibration, Milwaukee solution for conductivity meters
Milwaukee M10031B 1413µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895531

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10032B TDS calibration solution pouch front, 25 pouches of 20 ml each, calibration solution 1382 ppm for TDS measurement, practical single portions for accurate calibration
Milwaukee M10032B 1382 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895532

Die M10032B ist eine präzise TDS-Kalibrierlösung (1382 ppm) im Einwegbeutel. Perfekt für portable und Laborgeräte, wenn eine schnelle und saubere Kalibrierung erforderlich ist. Häufige Fragen Wofür brauche ich eine Puffer- oder Kalibrierlösung? Damit stellen Sie Ihr Messgerät richtig ein und sorgen für verlässliche Messwerte. Wie oft sollte ich mein Messgerät kalibrieren? Das hängt von der Nutzung ab. Bei häufiger Nutzung empfiehlt sich eine regelmäßige Kalibrierung. Passt die Milwaukee Kalibrierlösung auch zu anderen Messgeräten? In vielen Fällen ja, wenn der gleiche Messbereich verwendet wird. Kann ich eine geöffnete Lösung mehrfach verwenden? Ja, solange sie sauber bleibt und korrekt gelagert wird. Wie lagere ich Puffer- und Kalibrierlösungen richtig? Am besten kühl, trocken und gut verschlossen lagern. Woran erkenne ich, dass ich neu kalibrieren sollte? Wenn Messwerte ungewöhnlich wirken oder diese sich deutlich verändern.

€69.40*
Milwaukee M10038B 6.44 ppt TDS calibration solution sachet front with packaging in the background, 25 individual sachets of 20 ml each, calibration solution for TDS measuring devices, practical portion sachets
Milwaukee M10038B 6.44 ppt TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895533

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10080B TDS calibration solution bags, front view, 25 bags, 20 ml each, visible, calibration solution 800 ppm for TDS measurement, practical single portions, Milwaukee calibration solution for TDS measuring devices
Milwaukee M10080B 800 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895534

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*