Skip to main content Skip to search Skip to main navigation

Milwaukee EC59 waterproof Conductivity, TDS and Temperature Tester with replaceable probe

Article number: 895514
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Milwaukee EC59 waterproof Conductivity, TDS and Temperature Tester with replaceable probe"

Waterproof multifunction meter for measuring conductivity, TDS, and temperature. Features automatic temperature compensation, a replaceable probe, and simple calibration for various applications.

Milwaukee EC59 Waterproof Conductivity, TDS, and Temperature Meter – Precision and reliability for all water quality monitoring applications.

The Milwaukee EC59 combines conductivity (EC), TDS, and temperature measurements into a single, compact handheld device. By integrating multiple measurement parameters, it is ideal for users who need to assess water quality quickly and easily without carrying multiple instruments.

Automatic temperature compensation ensures reliable readings even when temperatures fluctuate. Additionally, automatic 1-point calibration allows for easy setup and regular accuracy checks, making the meter suitable for both beginners and experienced users.

A key advantage of the EC59 is its replaceable electrode. The electrode can be swapped out if it wears down or performance declines, thereby extending the device's service life. Its robust, waterproof housing makes it a reliable tool for use in laboratories, greenhouses, or directly in the field.

By simultaneously measuring conductivity, TDS, and temperature, the Milwaukee EC59 is suitable for a wide range of water quality monitoring and control applications.

Technical Specifications

  • Measurement parameters: Conductivity | TDS (Total Dissolved Solids) | Temperature
  • Measurement range: 0 to 3999 µS/cm | 0 to 2000 ppm TDS | 0.0 to 60.0 °C (32.0 to 140.0 °F)
  • Resolution: 1 µS/cm / 1 ppm / 0.1 °C / 0.1 °F
  • Accuracy (EC/TDS/Temp.): 2% of full scale | +/-0.5 °C (+/-1 °F)
  • Temperature compensation: Automatic

Key benefits at a glance

  • Measurement of conductivity, TDS, and temperature with a single device
  • Waterproof housing for daily use
  • Replaceable electrode for extended service life
  • Compact and user-friendly design
  • Ideal for portable and stationary measurements

Typical applications

  • Water treatment
  • Aquaculture
  • Hydroponics
  • Laboratory applications
  • Environmental analysis

Frequently Asked Questions

Yes, it is easy to use and the readings can be taken quickly.

You can check the water quality based on conductivity, TDS value and temperature.

Yes, the waterproof housing protects the device when used in damp environments.

Yes, the probe is replaceable and can be replaced if necessary.

The measurement is taken within a few seconds of immersion in water.

It is suitable for aquariums, hydroponics, swimming pools and many other water-related applications.

Yes, thanks to its handy size, it fits easily into a bag or toolbox.

Dimensions

Height 25,5 cm
Length 6,6 cm
Width 4,7 cm

Weight

Weight 120 g

Other attributes

Applications Aquaculture and Coral, Beverages, Environmental, Food, Laboratory, Schools, Water Conditioning, Water Treatment, Wine
Brand Milwaukee
Country of origin RO
Customs tariff number 90278930
Parameter Combined Multiparameter, Conductivity and TDS
Quality Advanced
Specifications
Measuring ranges
Conductivity measuring range: 0 to 3999 µS/cm
TDS measuring range: 0 to 2000 ppm
Temperature range: 0.0 to 60.0 °C (23 to 140 °F)
Measurement resolution
Conductivity Resolution: 1 µS/cm
TDS resolution: 1 ppm
Temperature resolution: 0.1 °C / 0.1 °F
Measurement accuracy (@25°C / 77°F)
Conductivity accuracy: ± 2% FS (full scale)
TDS accuracy:  ± 2% FS (full scale)
Temperature accuracy: ±0.5 °C (±1 °F)
Typical EMC deviation
±2% conductivity (full scale)
±2% TDS (full scale)
±0.5 °C / ±1 °F (full scale)
Temperature compensation
Automatic from ß=0.0 to 2.4%/ °C
Calibration
Automatic, 1 point
General
Electrode: replaceable (MI59P)
Environment: 0 to 50 °C / 32 to 122 °F; max. RH 100%
Battery type: 4 x 1.5 V alkaline (supplied)
Battery life: approx. 100 hours operating time
Dimensions: 200mm x diameter 38mm
Weight: approx. 100 g
Skip product gallery

Ersatzelektroden und Zubehör

Milwaukee M10032B TDS calibration solution pouch front, 25 pouches of 20 ml each, calibration solution 1382 ppm for TDS measurement, practical single portions for accurate calibration
Milwaukee M10032B 1382 ppm TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895532

Die M10032B ist eine präzise TDS-Kalibrierlösung (1382 ppm) im Einwegbeutel. Perfekt für portable und Laborgeräte, wenn eine schnelle und saubere Kalibrierung erforderlich ist. Häufige Fragen Wofür brauche ich eine Puffer- oder Kalibrierlösung? Damit stellen Sie Ihr Messgerät richtig ein und sorgen für verlässliche Messwerte. Wie oft sollte ich mein Messgerät kalibrieren? Das hängt von der Nutzung ab. Bei häufiger Nutzung empfiehlt sich eine regelmäßige Kalibrierung. Passt die Milwaukee Kalibrierlösung auch zu anderen Messgeräten? In vielen Fällen ja, wenn der gleiche Messbereich verwendet wird. Kann ich eine geöffnete Lösung mehrfach verwenden? Ja, solange sie sauber bleibt und korrekt gelagert wird. Wie lagere ich Puffer- und Kalibrierlösungen richtig? Am besten kühl, trocken und gut verschlossen lagern. Woran erkenne ich, dass ich neu kalibrieren sollte? Wenn Messwerte ungewöhnlich wirken oder diese sich deutlich verändern.

€69.40*
Milwaukee M10030B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml each, calibration solution 12880 µS/cm for conductivity measurement, practical individual bags for accurate calibration, Milwaukee calibration solution for conductivity meters
Milwaukee M10030B 12880 µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895530

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10031B Conductivity Calibration Solution Bag Front, 25 bags of 20 ml visible, calibration solution 1413 µS/cm, practical single portions for calibration, Milwaukee solution for conductivity meters
Milwaukee M10031B 1413µS/cm conductivity calibration solution in a sachet, 25 sachets á 20ml
Article number: 895531

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee M10038B 6.44 ppt TDS calibration solution sachet front with packaging in the background, 25 individual sachets of 20 ml each, calibration solution for TDS measuring devices, practical portion sachets
Milwaukee M10038B 6.44 ppt TDS Calibration Solution in a sachet, 25 sachets á 20ml
Article number: 895533

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€69.40*
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060) Product number: 896157
Milwaukee 12880 µS/cm Conductivity Calibration Solution 230ml (MA9060)
Article number: 896157
Kalibierlösung: 12880 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€53.00*
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061) Product number: 896158
Milwaukee 1413 µS/cm Conductivity Calibration Solution 230ml (MA9061)
Article number: 896158
Kalibierlösung: 1413 μS/cm (@25°C)

Frequently Asked Questions Why do I need a buffer or calibration solution? It allows you to set up your measuring device correctly and ensures reliable readings. How often should I calibrate my measuring device? That depends on how often you use it. If used frequently, regular calibration is recommended. Is the Milwaukee calibration solution also suitable for other measuring devices? In many cases, yes, provided the same measurement range is used. Can I use an opened solution more than once? Yes, as long as it remains clean and is stored correctly. How do I store buffer and calibration solutions correctly? It is best to store them in a cool, dry place and keep them tightly sealed. How do I know when I should recalibrate? If the readings seem unusual or change significantly.

€46.40*
Milwaukee Cleaning Solution, 230ml (MA9016) Product number: 896166
Milwaukee Cleaning Solution, 230ml (MA9016)
Article number: 896166

for pH/ORP electrodes

€46.40*