HORIBA Electrodes & Sensors – Precise Measurement Technology for Reliable Analyses
High-quality sensor technology for accurate measurement of various water parameters
In this category, you will find electrodes and sensors from HORIBA for the precise determination of various water and process parameters. The components are specifically designed for reliable use in different applications and enable accurate and stable measurement results.
Reliable measurement values for demanding applications with Horiba sensor technology
The electrodes and sensors measure important parameters such as pH value, redox, conductivity, or dissolved oxygen. They form the basis for precise analysis and a reliable evaluation of water and process conditions.
Thanks to their robust design and high measurement accuracy, the sensors are suitable for continuous applications as well as for demanding operating conditions.
Why are high-quality sensors crucial?
-
Direct basis of measurement
The electrode is the central element of every measurement. Its quality determines the accuracy of the results. -
Stability and reliability
High-quality sensors provide consistent values. This is essential for safe process control. -
Adaptation to different applications
Depending on the medium and application, specific sensors are required. This ensures optimal measurement results.
Typical application areas
- Water treatment and process monitoring
- Industrial and plant control
- Laboratory and quality analyses
- Environmental analysis and water monitoring
Your added value in
- Reliable measurement technology for various parameters
- Robust designs for different applications
- Support for stable and accurate measurement results
Benefit from high-quality sensor technology and ensure the accuracy of your measurements in every application.
- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- OFFERS
- Accessories
- Training courses
- Service & Company
- Areas of Application
Thank you for your interest in our smart and individually configurable measuring instruments of the HORIBA LAQUA WQ-300 series. The high-quality digital multi-parameter handheld meters feature a large colour LCD display with LED backlight (7 cm x 5.2 cm), making them ideally suited for field use under a wide range of conditions and in direct daylight. Use our configurator to select the appropriate measuring instrument from the HORIBA WQ-300 series with 1 to 3 measuring channels, the desired measuring parameters (sensor cartridges) and the required cable length according to your individual needs. The sensor cables feature an integrated sensor receptacle and digital module. Additional measuring parameters can also be connected at a later stage using the corresponding sensor cable or carried in the measuring case as supplementary equipment. As with other HORIBA handheld meters, the devices are particularly resistant to shocks, slipping and scratches thanks to their special rubber coating. Operation requires four standard AA batteries with 2500 mAh. For greater flexibility during mobile use, the WQ-300 series can alternatively be powered by a power bank or battery pack via the integrated USB interface. An IP67 certification, which confirms dust-tightness and protection against temporary immersion for up to 30 minutes at a water depth of one metre, completes the professional overall package alongside the ergonomic design and easy operation. HORIBA offers a three-year warranty on the handheld measuring instruments of the LAQUA WQ-300 series. Functions and Features During measurements, users are supported by operating instructions displayed in the form of smiley symbols. These are complemented by an LED status indicator on the sensor to help prevent operating errors and implausible measurement results. The small number of control buttons and the absence of complex, nested menus ensure that the instruments remain easy and safe to operate, even when used intermittently or by different users. Additional Functions Electrode wear indicator Measurement stability indicator on the instrument and sensor Hold function to "save" the current measured value on the display Individual measuring point identification with up to 8 characters Automatic calibration functions Integrated sensor holders Self-diagnostic function GLP functions Fold-out stand for convenient hands-free measurements Transfer of measurement data to a computer or smartphone via USB or WiFi Measuring Case for Mobile Use All handheld meters of the WQ-300 series are supplied in a reinforced measuring case for mobile outdoor use. The case provides space for the measuring instrument, electrodes and cables, as well as up to eight 60 ml bottles of buffer solutions. An integrated holder for buffer solution bottles facilitates calibration. Automatic Sensor Recognition A particular advantage of the WQ-300 series is automatic sensor recognition through sensor cables with integrated digital sensor receptacles. Information about the sensor, calibration data and measurement settings is stored in the digital sensor module and transmitted to the measuring instrument. In addition, all connected sensors can be calibrated simultaneously, as each sensor module independently stores measurement and calibration data and transmits them to the WQ-300 series measuring instrument. Analogue sensors can optionally be connected using the HORIBA BNC sensor adapter. Please contact us for further information. Available Languages German English French Spanish Portuguese Chinese Scope of Delivery WQ-300 series handheld meter in a carrying case Selected digital electrode, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptacle Instruction manual Manufacturer Article Number WQ-310-K (1 channel): 3200832605 Calibrating the Instrument pH Measurement To obtain accurate results, a two-point calibration must be carried out. The following buffer solutions are recommended: pH 7.00 and 4.01 for acidic samples pH 7.00 and 10.01 for alkaline samples If the expected pH value of the sample is unknown, a three-point calibration using pH 7.00, 4.01 and 10.01 is recommended. It is recommended to begin calibration with pH 7.00. Conductivity Measurement For conductivity measurements, a single-point calibration is sufficient, for example at 1413 µS/cm. For greater accuracy, a multi-point calibration can also be performed. Important Note on the Chloride Sensor Note: If a chloride sensor is selected, it is supplied without chloride ionic strength adjuster and chloride electrode filling solution. These solutions must be purchased separately by the customer. The chloride sensor cannot be used without the required filling solution. Why We Use These Measuring Devices in Water Treatment Precise calcium control is an important element of efficient water treatment, from drinking water purification and process water management to environmental analysis. Elevated calcium concentrations can contribute to scale formation, pipe damage, increased energy consumption and disruptions in chemical processes. For these applications, we offer configurable solutions from the HORIBA LAQUA WQ series in our online shop. Available Measuring Instruments WQ310-K: Single-channel solution for targeted measurements. WQ320-K: Simultaneous measurement of two parameters, such as calcium and conductivity. WQ330-K: Three-channel measurement for complex multi-parameter analyses. Benefits for Water Treatment Reliable measurement data for monitoring and optimising water treatment systems. Digital evaluation, documented measurement results and interfaces for data transfer. Robust design and practical measuring case for mobile on-site use. Flexible combination of calcium measurements with other parameters such as pH, conductivity or redox potential. Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required.
Thank you for your interest in our smart and individually configurable measuring instruments of the HORIBA LAQUA WQ-300 series. The high-quality digital multi-parameter handheld meters feature a large colour LCD display with LED backlight (7 cm x 5.2 cm), making them ideally suited for field use under a wide range of conditions and in direct daylight. Use our configurator to select the appropriate measuring instrument from the HORIBA WQ-300 series with 1 to 3 measuring channels, the desired measuring parameters (sensor cartridges) and the required cable length according to your individual needs. The sensor cables feature an integrated sensor receptacle and digital module. Additional measuring parameters can also be connected at a later stage using the corresponding sensor cable or carried in the measuring case as supplementary equipment. As with other HORIBA handheld meters, the devices are particularly resistant to shocks, slipping and scratches thanks to their special rubber coating. Operation requires four standard AA batteries with 2500 mAh. For greater flexibility during mobile use, the WQ-300 series can alternatively be powered by a power bank or battery pack via the integrated USB interface. An IP67 certification, which confirms dust-tightness and protection against temporary immersion for up to 30 minutes at a water depth of one metre, completes the professional overall package alongside the ergonomic design and easy operation. HORIBA offers a three-year warranty on the handheld measuring instruments of the LAQUA WQ-300 series. Functions and Features During measurements, users are supported by operating instructions displayed in the form of smiley symbols. These are complemented by an LED status indicator on the sensor to help prevent operating errors and implausible measurement results. The small number of control buttons and the absence of complex, nested menus ensure that the instruments remain easy and safe to operate, even when used intermittently or by different users. Additional Functions Electrode wear indicator Measurement stability indicator on the instrument and sensor Hold function to "save" the current measured value on the display Individual measuring point identification with up to 8 characters Automatic calibration functions Integrated sensor holders Self-diagnostic function GLP functions Fold-out stand for convenient hands-free measurements Transfer of measurement data to a computer or smartphone via USB or WiFi Measuring Case for Mobile Use All handheld meters of the WQ-300 series are supplied in a reinforced measuring case for mobile outdoor use. The case provides space for the measuring instrument, electrodes and cables, as well as up to eight 60 ml bottles of buffer solutions. An integrated holder for buffer solution bottles facilitates calibration. Automatic Sensor Recognition A particular advantage of the WQ-300 series is automatic sensor recognition through sensor cables with integrated digital sensor receptacles. Information about the sensor, calibration data and measurement settings is stored in the digital sensor module and transmitted to the measuring instrument. In addition, all connected sensors can be calibrated simultaneously, as each sensor module independently stores measurement and calibration data and transmits them to the WQ-300 series measuring instrument. Analogue sensors can optionally be connected using the HORIBA BNC sensor adapter. Please contact us for further information. Available Languages German English French Spanish Portuguese Chinese Scope of Delivery WQ-300 series handheld meter in a carrying case Selected digital electrode, if applicable, and the corresponding sensor-specific cable with integrated digital sensor receptacle Instruction manual Manufacturer Article Number WQ-320-K (2 channels): 3200832606 Calibrating the Instrument pH Measurement To obtain accurate results, a two-point calibration must be carried out. The following buffer solutions are recommended: pH 7.00 and 4.01 for acidic samples pH 7.00 and 10.01 for alkaline samples If the expected pH value of the sample is unknown, a three-point calibration using pH 7.00, 4.01 and 10.01 is recommended. It is recommended to begin calibration with pH 7.00. Conductivity Measurement For conductivity measurements, a single-point calibration is sufficient, for example at 1413 µS/cm. For greater accuracy, a multi-point calibration can also be performed. Important Note on the Chloride Sensor Note: If a chloride sensor is selected, it is supplied without chloride ionic strength adjuster and chloride electrode filling solution. These solutions must be purchased separately by the customer. The chloride sensor cannot be used without the required filling solution. Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required.
Horiba WQ330-K – Your Professional 3-Channel Water Quality Meter Expandable multi-parameter system for simultaneous measurement of pH, conductivity, redox, and other water parameters The Horiba LAQUA WQ330-K is a powerful multi-channel device for advanced water analysis, both on-site and in the laboratory. With three freely configurable measurement channels, it can simultaneously record parameters such as pH, conductivity, redox potential, TDS, temperature, oxygen, ammonia, calcium, chloride, nitrate, fluoride, and potassium. Intuitive operation, automatic sensor recognition, and digital calibration ensure accurate, fast, and reproducible measurements. Flexible Multi-Parameter System for Field and Laboratory Applications The analysis kit with the Horiba WQ330-K is ideal for environmental and water body monitoring, research and teaching, as well as drinking and process water control. The large LCD display with LED backlight ensures excellent readability even in direct sunlight. Measurement data can be exported and documented via USB or wirelessly, greatly simplifying traceability and analysis. The modular system allows the device to be quickly and precisely adapted to any measurement task. It is ideal for users who need to efficiently and reliably monitor multiple water parameters. Technical Features and Key Advantages of the WQ330-K The three measurement channels of the Horiba WQ330-K enable simultaneous recording of different water parameters, reducing measurement time and allowing better evaluation of relationships between parameters. The modular sensor concept allows flexible use of digital sensors, which are automatically recognized and store their calibration history. Notably, the combination of high measurement precision, user-friendliness, and mobility makes this device stand out. Quick deployment without complicated setup, along with easy data transfer for documentation and analysis, makes the Horiba LAQUA WQ330-K an ideal solution for professional water analytics. Calibrating the instrument: pH measurement To obtain accurate results, a two-point calibration must be carried out. It is recommended that the following solutions be used: pH 7.00 and 4.01 for acidic samples pH 7.00 and 10.01 for alkaline samples Carry out a three-point calibration using pH 7.00, 4.01 and 10.01 if you do not know the expected pH value of the sample. It is recommended that you calibrate using pH 7.00 first. Conductivity measurement For a conductivity measurement, a single-point calibration is sufficient, for example at 1413 μS/cm. For greater accuracy, a multi-point calibration can also be carried out. Note: During the promotional period, the discount on accessories will be automatically deducted at the shop’s checkout when purchased together with the HORIBA WQ330 device. Note on Scope of Delivery: From November 2026, HORIBA products will be supplied without batteries. Existing stock may still include batteries. Batteries are no longer included with newly manufactured products and must be purchased separately if required. Frequently asked questions How long is the warranty period for HORIBA analysers? The warranty period is 2 years for the 300 (WQ) series and 1 year for the F series after delivery. Where can I find suitable replacement electrodes or buffer solutions? You can find the appropriate replacement electrodes and buffer solutions in the shop under the main item at the bottom of the cross-selling section. How do I clean the probe before calibration? The sensors should be cleaned with DI water (deionised). After cleaning, wipe them with tissue paper if possible. Frequently asked questions about the promotion How long does the promotion run for? The promotion runs from 1 September 2026 to 31 December 2026. How do I get the discount on the accessories? The discount will be automatically deducted at the shop’s checkout when you purchase the HORIBA WQ330 unit at the same time.
Manufacturer Part Nr. 3200459834
The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, regular monitoring of the sensors and, if necessary, replacement with spare sensors is essential. The replacement sensors are specifically designed for the HORIBA LAQUAtwin series and cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is engineered to maximize user-friendliness and accuracy, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and precise measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: The sensors can be replaced quickly, allowing measurements to continue without delay. High Precision: Replacement sensors ensure that results are accurate and reliable. Wide Measurement Range: Various sensor types are available to cover a broad spectrum of water quality parameters. Durability: The sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions: Follow these steps when replacing the sensor to ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester: Removing the Sensor: Turn off the tester. Lift the sensor tip slightly and pull the sensor a short distance away from the device. Completely detach the sensor from the tester. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is intact and clean. Place the sensor onto the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurement. These manuals are available with the products and typically require calibration and, if necessary, conditioning. How can I tell if my sensor is worn out? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, the sensor should be replaced. Regular checks and timely sensor replacement ensure that water quality measurements with HORIBA LAQUAtwin Pocket Testers remain accurate and reliable. Manufacturer Part Nr. 3200459869
The HORIBA LAQUAtwin Pocket Tester series allows water quality parameters to be measured quickly and accurately directly on site. To ensure that these measurements are reliable and accurate, it is essential to check the sensors regularly and replace them with replacement sensors where necessary. These replacement sensors have been specifically developed for the HORIBA LAQUAtwin series and offer a wide range of variants for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium and fluoride. Each of these sensors has been developed with the aim of maximising the user-friendliness and accuracy for which HORIBA is renowned worldwide in the field of water quality testing. The advantages of HORIBA replacement sensors are: Easy replacement: The sensors are easy to replace, allowing measurements to resume quickly. Highest accuracy: The replacement sensors ensure that measurement results are precise and reliable. Wide range of measurements: Various types of sensors are available for different water quality parameters. Durability: The sensors are designed to have a long service life, even under challenging conditions. Instructions for sensor replacement: To ensure that your HORIBA LAQUAtwin Pocket Tester remains durable and accurate, please follow these steps when replacing the sensor: Removing the sensor Switch off the meter. Lift the tip of the sensor. Then slide the sensor slightly away from the meter. Remove the sensor completely from the meter (by pulling). Fitting the sensor Switch off the meter. Ensure that the water-resistant seal is clean and undamaged. Press the sensor onto the meter so that the hook ‘A’ on the back of the meter fits into the hole ‘a’ on the sensor tab. Make sure that the waterproof seal is not twisted. Important: To get the measuring device back up and running for accurate measurements, follow the steps in the user manual for the relevant tester after replacing the sensor. (Our products include such manuals. In most cases, calibration and, if necessary, conditioning are required.) Question: How can I check if my sensor is worn out? Answer: By checking the condition of the sensor as follows: To check the sensor condition, perform a 2-point calibration. If a calibration error occurs, this suggests that the sensor is deteriorating. The sensor should therefore be replaced. By carrying out regular checks and replacing sensors in good time, you can ensure the high quality and reliability of your water quality measurements using the HORIBA LAQUAtwin Pocket Testers. Important note on compatibility Please note: The Horiba LAQUAtwin conductivity, TDS and temperature multi-parameter testers, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell whether you have an older or a newer device? If your pocket tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new pocket testers and are not suitable for the older models. Manufacturer’s item number: 3200459672
The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, it is essential to regularly check the sensors and, if necessary, replace them with spare sensors. The replacement sensors, specifically designed for the HORIBA LAQUAtwin series, cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is engineered to maximize user-friendliness and accuracy, for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and precise measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be quickly replaced, allowing measurements to continue without delay. High Accuracy: Replacement sensors ensure that results are exact and reliable. Comprehensive Measurement Range: Various sensor types are available to cover a wide range of water quality parameters. Durability: Sensors are designed for long service life under challenging conditions. Sensor Replacement Instructions: Follow these steps when replacing the sensor to maintain the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester: Removing the Sensor: Turn off the tester. Move the sensor slightly away from the device and lift the sensor tip. Detach the sensor completely from the tester. Installing the Sensor: Ensure the tester is turned off. Make sure the waterproof gasket is clean and intact. Mount the sensor onto the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip. Ensure the waterproof gasket is not twisted. Important: After replacing the sensor, follow the steps in the user manual of the respective tester to make the device ready for accurate measurement. (These manuals are available with the products. Calibration and, if necessary, conditioning are usually required.) How can I check if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, it is advisable to replace the sensor. Regular checks and timely sensor replacement ensure that water quality measurements performed with the HORIBA LAQUAtwin Pocket Testers remain highly accurate and reliable. Manufacturer Part Nr. 3200997083
To ensure measurements remain reliable and accurate, it is important to regularly check the sensor and replace it with a spare sensor if necessary. The replacement sensor is specifically designed for the HORIBA LAQUAtwin Ca-11C for animal blood. This sensor is engineered to optimize user-friendliness and accuracy. With HORIBA replacement sensors, users can be confident that their devices consistently deliver optimal performance and precise results. Advantages of HORIBA Replacement Sensors: Easy Replacement: Sensors can be quickly replaced, allowing measurements to continue without delay. High Accuracy: Replacement sensors ensure that results are precise and reliable. Comprehensive Measurement Range: Various sensor types are available to measure a wide range of parameters. Durability: Sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions: To ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester, please follow these instructions when replacing a sensor: Removing the Sensor: Turn off the tester. Carefully detach the sensor from the device and lift the sensor tip. Completely separate the sensor from the tester so that the two components are no longer connected. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is clean and intact. Attach the sensor to the tester by inserting hook “A” on the back of the device into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, it is essential to follow the steps in the user manual of the respective tester to make the device ready for accurate measurements. These manuals are available with the products. Calibration and, if necessary, conditioning are usually required. How can I tell if my sensor shows signs of wear? Check the sensor condition as follows: Perform a 2-point calibration to assess the sensor’s condition. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, replacing the sensor is recommended. Regular checks and timely replacement of sensors are essential to maintain the high standards and reliability of water quality measurements performed with HORIBA LAQUAtwin Pocket Testers. S051 Calcium replacement sensor for Ca-11C Manufacturer article number: 3200772945