- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Service & Company
- Training courses
Filter products
Manufacturer number: 3200360505This refillable pH electrode with plastic housing and integrated temperature sensor is recommended for general use.
Manufacturer number: 320052411This plastic-body, refillable pH electrode with integrated temperature sensor can measure 1% hydrofluoric acid solution (at 25°C, immersed for 1min) for about 1000X. Suitable for drain water measurement after etching process.
The Horiba 9652-10D pH electrode with double diaphragm is a durable, gel-filled glass electrode in a robust plastic housing, specially developed for mobile use with handheld measuring devices from the LAQUA 200 series. It covers a measuring range from 0 to 14 pH and guarantees reliable results in a temperature range from 0 to 80 °C. The combination of a double diaphragm (double junction) and a porous, sintered polyethylene contact ensures stable measuring performance even under demanding conditions. An integrated temperature sensor enables accurate, temperature-compensated pH measurements. Thanks to its gel filling, the electrode is virtually maintenance-free and does not require refilling of the electrolyte solution. Manufacturer item number: 3200786359
The Horiba 9652-20D pH electrode with double diaphragm is a gel-filled pH glass electrode in a robust plastic housing, ideal for outdoor use in conjunction with handheld measuring devices from the LAQUA 200 series. It offers a measuring range from 0 to 14 pH and works reliably in a temperature range from 0 to 80 °C. Thanks to the double diaphragm (double junction) and the porous, sintered polyethylene liquid contact, it ensures high measurement stability. An integrated temperature sensor ensures precise, temperature-compensated measurements. The electrode is low-maintenance as it is gel-filled and does not need to be refilled. Manufacturer Part Nr. 3200786361
Manufacturer number: 3200585455This refillable pH electrode with integrated temperature sensor is ideal for testing samples in large containers and long test tubes (e.g., microbial culture fluids) due to its long, thin, glass-body.Electrode: 251mm length, 7mm diameterConstructed with responsive glass that is 10x stronger than JIS standardsWaterproof, Pb-free glass
Manufacturer number: 3200585463pH electrode with integrated temperature sensor for stable measurements of highly viscous samples. The saline bridge part is equipped with a movable sleeve that can be easily cleaned to prevent viscous samples from clogging the saline bridge and to keep measurements stable and accurate.Rapid stabilisation and reduction of aeronauticsToupH electrodes use sensitive glass, reducing the risk of damageWaterproof (IP-67), pb-free glassWhen measuring samples with high viscosity or non-aqueous solutions (e.g. paints or cosmetics), we recommend using the instrument's chart function to ensure stability.
Manufacturer's number: 3200705774Ammonia (NH3) ISE replacement membranes (3 pieces) for 5002S-10C
The Horiba LAQUA 300 BNC adapter is an intermediate piece to connect an ion selective electrode to the Smart Sensor Module with cable to an 300 series meter. After prior clarification with our company, your previous pH and redox electrodes can, if applicable, be connected to the 300 series meter after a compatibility check.Manufacturer number: 3200821465
300-2C2C, 2-cell conductivity sensor cartridge, stainless steel, K=0.1 0.01 to 500µS/cm to 2000 mS/cmManufacturer article number: 3200820579
300-4C-C, 4 cell conductivity sensor cartridge, epoxy, carbon body, 10µS/cm to 2000 mS/cmManufacturer article number: 3200780928
Conductivity/TDS/resistivity/salinity cable with digital sensor head to mount the conductivity sensors of type "300-2C2C" and "300-4C-C". Manufacturer Part Nr. : 3200784468 (2 metres 300-C-2) 3200812202 (5 metres 300-C-5)
Conductivity/TDS/resistivity/salinity cable with digital sensor head to mount the conductivity sensors of type "300-2C2C" and "300-4C-C". Manufacturer Part Nr. : 3200784468 (2 metres 300-C-2) 3200812202 (5 metres 300-C-5)
Optical dissolved oxygen sensor with hard moulded 2m or 5m cable including a membrane cap. Manufacturer Part Nr. 3200780940 (2 metres = 300-D-2) 3200780942 (5 metres = 300-D-5)
Optical dissolved oxygen sensor with hard moulded 2m or 5m cable including a membrane cap. Manufacturer Part Nr. 3200780940 (2 metres = 300-D-2) 3200780942 (5 metres = 300-D-5)
The HORIBA Dissolved Oxygen Sensor Cap (300-D-M) is an essential component for performing precise and reliable dissolved oxygen measurements in aqueous environments. This replacement cap is designed for use with HORIBA DO sensors models 300-D-2 and 300-D-5. It is the ideal solution for ensuring the measurement accuracy and longevity of your oxygen meter. Advantages of the HORIBA Dissolved Oxygen Sensor Cap Extended Measurement Range: The sensor cap allows for comprehensive dissolved oxygen measurements, making it suitable for a wide variety of applications, from environmental monitoring to industrial processes. Adaptability to Environmental Conditions: With its operating temperature range, it can be used for measurements in diverse aqueous environments, from cool natural waters to warmer industrial process waters. Durable Material: Made from PVC and PMMA, the sensor cap offers high resistance to chemical exposure and mechanical stress, ensuring durability in challenging measurement conditions. Easy Installation: The sensor cap can be replaced quickly and easily, reducing maintenance time and improving operational efficiency. Quick Guide to Replacing the Sensor Cap Remove the old cap: Detach the existing sensor cap from the DO sensor to make room for the new one. Attach the new cap: Secure the new sensor cap to the DO sensor so it can be quickly put back into service. Set the parameters: Enter the specific membrane parameters of the new cap into the meter to optimize measurement accuracy. Calibration process: Use the dedicated calibration function (“CAL in cap replacement”) to fine-tune the measurements with the new cap. Note: The detailed procedure for setting the membrane parameters and performing calibration is described in the device’s user manual. Following these steps ensures your meter is promptly and efficiently configured for the new sensor cap, maintaining accurate measurements over time. For anyone who depends on precise dissolved oxygen measurements, the HORIBA Dissolved Oxygen Sensor Cap (300-D-M) is indispensable. With its robust design, extended measurement range, and ease of use, it greatly enhances the reliability and service life of your HORIBA oxygen meter. Replacement DO cap for 300-D-2 and 300-D-5Manufacturer article number: 3200781554
Cable with digital sensor head to accommodate the ion selective sensors. Manufacturer Part Nr. :3200812203 (2 metres 300-I-2) 3200923560 (5 metres 300-I-5) Note: To use the ion selective sensors, the respective adapters are required.
Cable with digital sensor head to accommodate the ion selective sensors. Manufacturer Part Nr. :3200812203 (2 metres 300-I-2) 3200923560 (5 metres 300-I-5) Note: To use the ion selective sensors, the respective adapters are required.
ORP cable with digital sensor head to mount the "300-O-C ORP electrode". Manufacturer Part Nr. : 3200812204 (2 metres 300-O-2) 3200923561 (5 metres 300-O-5)
ORP cable with digital sensor head to mount the "300-O-C ORP electrode". Manufacturer Part Nr. : 3200812204 (2 metres 300-O-2) 3200923561 (5 metres 300-O-5)
300-P-C pH sensor cartridgeManufacturer article number: 3200786363
pH cable with digital sensor head to mount the "300-P-C pH electrode". Manufacturer Part Nr. : 3200812206 (2 metres 300-PH-2) 3200812207 (5 metres 300-PH-5)
pH cable with digital sensor head to mount the "300-P-C pH electrode". Manufacturer Part Nr. : 3200812206 (2 metres 300-PH-2) 3200812207 (5 metres 300-PH-5)
Manufacturer Part Nr. 3200459834
The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for immediate and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, regular monitoring of the sensors and, if necessary, replacement with spare sensors is essential. The replacement sensors are specifically designed for the HORIBA LAQUAtwin series and cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is engineered to maximize user-friendliness and accuracy, qualities for which HORIBA is globally recognized in water quality testing. HORIBA replacement sensors ensure that users’ devices consistently deliver optimal performance and precise measurements. Advantages of HORIBA Replacement Sensors: Easy Replacement: The sensors can be replaced quickly, allowing measurements to continue without delay. High Precision: Replacement sensors ensure that results are accurate and reliable. Wide Measurement Range: Various sensor types are available to cover a broad spectrum of water quality parameters. Durability: The sensors are designed for long service life, even under challenging conditions. Sensor Replacement Instructions: Follow these steps when replacing the sensor to ensure the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester: Removing the Sensor: Turn off the tester. Lift the sensor tip slightly and pull the sensor a short distance away from the device. Completely detach the sensor from the tester. Installing the Sensor: Ensure the tester is turned off. Check that the waterproof gasket is intact and clean. Place the sensor onto the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip. Make sure the waterproof gasket is not twisted. Important: After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurement. These manuals are available with the products and typically require calibration and, if necessary, conditioning. How can I tell if my sensor is worn out? Check the sensor condition as follows: Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, the sensor should be replaced. Regular checks and timely sensor replacement ensure that water quality measurements with HORIBA LAQUAtwin Pocket Testers remain accurate and reliable. Manufacturer Part Nr. 3200459869