HORIBA Electrodes & Sensors – Precise Measurement Technology for Reliable Analyses
High-quality sensor technology for accurate measurement of various water parameters
In this category, you will find electrodes and sensors from HORIBA for the precise determination of various water and process parameters. The components are specifically designed for reliable use in different applications and enable accurate and stable measurement results.
Reliable measurement values for demanding applications with Horiba sensor technology
The electrodes and sensors measure important parameters such as pH value, redox, conductivity, or dissolved oxygen. They form the basis for precise analysis and a reliable evaluation of water and process conditions.
Thanks to their robust design and high measurement accuracy, the sensors are suitable for continuous applications as well as for demanding operating conditions.
Why are high-quality sensors crucial?
-
Direct basis of measurement
The electrode is the central element of every measurement. Its quality determines the accuracy of the results. -
Stability and reliability
High-quality sensors provide consistent values. This is essential for safe process control. -
Adaptation to different applications
Depending on the medium and application, specific sensors are required. This ensures optimal measurement results.
Typical application areas
- Water treatment and process monitoring
- Industrial and plant control
- Laboratory and quality analyses
- Environmental analysis and water monitoring
Your added value in
- Reliable measurement technology for various parameters
- Robust designs for different applications
- Support for stable and accurate measurement results
Benefit from high-quality sensor technology and ensure the accuracy of your measurements in every application.
Filter products
Manufacturer's number: 3014046709For general use Plastic housing, titanium/platinum black, k=1, conductivity cell with integrated temperature sensorWaterproofunder water measurements up to a depth of 1 meter
Manufacturer number: 3200611623This glass-body, refillable pH electrode is recommended for a wide range of applications, including pH buffers and aqueous test solutions.Offers quick stability and drift reductionConstructed with responsive glass that is 10x stronger than JIS standardsThe dome-shaped tip provides strength in all directions, reducing damage concernsWaterproof, Pb-free glass
Manufacturer number: 3200611627This glass-body, refillable pH electrode can measure samples as low as 50µL.Compatible with extremely small sample containers (e.g., microtubes)Temperature sensor is placed beside the bulb for quick responseWaterproof
Manufacturer number: 3200611625This plastic-body, refillable pH electrode is recommended for general-purpose use.
Horiba 9521-10D DO ElectrodeGalvanic DO Electrode for DO and BOD measurements in laboratories Ideal for laboratory useIntegrated with built-in temperature sensorComes with replaceable 7544 DO Electrode Tip, detachable BOD bottle adapter and stirrer Use magnetic stir plate during measurementWaterproof Dissolved Oxygen Range: 0 to 20.00 mg/LTemperature Range: 0 to 50 °CResponse Time: 20 seconds (90% response time at constant temperature)Connectors: BNC, phono jackCable Length: 1 mOverall Length: 183 mmDiameter: 15.6 mmReplacement DO Tip: 7544Manufacturer article number: 3200891722
The Horiba 9600-10D PUREIL pH electrode can perform pH measurements in water within five minutes without affecting its conductivity thanks to its gel ion liquid salt bridge. This pH electrode allows pH values in water with low conductivity to be measured accurately and quickly. An innovative pH electrode that does not release KCl Accurate readings through quick and easy measurement This pH electrode is used to determine pH values in water in order to reliably determine pH values. It supports measurements in the pH range 0-14 and is ideal for water with low conductivity (<100 µS/cm) such as ultrapure water samples (e.g., distilled water, rainwater, reverse osmosis water, and boiler water). KCl is usually diffused in pH electrodes, but the use of a newly developed ionic liquid salt bridge now makes it possible to stabilize the potential difference at the liquid interface. When measuring with the 9600-10D PUREIL pH electrode, no potassium chloride is released that could influence the measurement or the pH value in samples with low ionic strength or special solutions. Advantages: Maintenance-free and waterproof Built-in temperature sensor for automatic temperature compensation Minimal dissolution of the ionic liquid during the measurement process Precise and fast measurement even with samples with low electrical conductivity The impact on the sample is a maximum of 1/10,000 compared to conventional methods Measurements are also possible with samples that react with KCl Waterproof construction Suitable for: Can be used for water with low electrical conductivity (pure water, rainwater, river water) and medical solutions (injections). Solutions that react with KCl (potassium chloride) or contain ions, such as injection solutions. Not suitable for: Since the Pure IL pH electrode uses an ionic liquid as a salt bridge as a reference electrode, it is not suitable for measuring samples containing surfactants, heavy metal ions, or organic solvents. For acidic samples, citrate buffer (pH 3.776 at 25 °C) is recommended for calibration instead of phthalate buffer (pH 4.01 at 25 °C) in order to achieve a more accurate measurement. Why should I use this electrode? The 9600-10D PUREIL is a very good and stable pH electrode. If you value speed and accuracy, this electrode is the right choice. Choose the winner of the 2012 Super Monozukuri Parts Award in the “Healthcare and Medical Equipment Parts” category.
Manufacturer Part Number: 3200585428This glass-body, refillable pH electrode with integrated temperature sensor is recommended for a wide range of applications, including pH buffers and aqueous test solutions. Offers quick stability and drift reductionConstructed with responsive glass that is 10x stronger than JIS standardsThe dome-shaped tip provides strength in all directions, reducing damage concernsWaterproof, Pb-free glass
Manufacturer number: 3200585447This refillable glass-body pH electrode with temperature sensor can measure samples as low as 50µL.Compatible with extremely small sample containers (e.g., microtubes)Temperature sensor is placed beside the bulb for quick responseWaterproof
Manufacturer number: 3200360505This refillable pH electrode with plastic housing and integrated temperature sensor is recommended for general use.
Manufacturer number: 320052411This plastic-body, refillable pH electrode with integrated temperature sensor can measure 1% hydrofluoric acid solution (at 25°C, immersed for 1min) for about 1000X. Suitable for drain water measurement after etching process.
The Horiba 9652-10D pH electrode with double diaphragm is a durable, gel-filled glass electrode in a robust plastic housing, specially developed for mobile use with handheld measuring devices from the LAQUA 200 series. It covers a measuring range from 0 to 14 pH and guarantees reliable results in a temperature range from 0 to 80 °C. The combination of a double diaphragm (double junction) and a porous, sintered polyethylene contact ensures stable measuring performance even under demanding conditions. An integrated temperature sensor enables accurate, temperature-compensated pH measurements. Thanks to its gel filling, the electrode is virtually maintenance-free and does not require refilling of the electrolyte solution. Manufacturer item number: 3200786359
The Horiba 9652-20D pH electrode with double diaphragm is a gel-filled pH glass electrode in a robust plastic housing, ideal for outdoor use in conjunction with handheld measuring devices from the LAQUA 200 series. It offers a measuring range from 0 to 14 pH and works reliably in a temperature range from 0 to 80 °C. Thanks to the double diaphragm (double junction) and the porous, sintered polyethylene liquid contact, it ensures high measurement stability. An integrated temperature sensor ensures precise, temperature-compensated measurements. The electrode is low-maintenance as it is gel-filled and does not need to be refilled. Manufacturer Part Nr. 3200786361
Manufacturer number: 3200585455This refillable pH electrode with integrated temperature sensor is ideal for testing samples in large containers and long test tubes (e.g., microbial culture fluids) due to its long, thin, glass-body.Electrode: 251mm length, 7mm diameterConstructed with responsive glass that is 10x stronger than JIS standardsWaterproof, Pb-free glass
Manufacturer number: 3200585463pH electrode with integrated temperature sensor for stable measurements of highly viscous samples. The saline bridge part is equipped with a movable sleeve that can be easily cleaned to prevent viscous samples from clogging the saline bridge and to keep measurements stable and accurate.Rapid stabilisation and reduction of aeronauticsToupH electrodes use sensitive glass, reducing the risk of damageWaterproof (IP-67), pb-free glassWhen measuring samples with high viscosity or non-aqueous solutions (e.g. paints or cosmetics), we recommend using the instrument's chart function to ensure stability.
Manufacturer's number: 3200705774Ammonia (NH3) ISE replacement membranes (3 pieces) for 5002S-10C
Nitrate (NO3-) ion selective electrode for 300 seriesThe new electrode is suitable for the LAQUA WQ-300 series from Horiba and offers precise and reliable measurements for ions in aqueous solutions. It is characterised by its user-friendly handling and environmentally friendly design and can be used for a wide range of applications.Features:Measurement parameters: Nitrate (NO3-) Solid-state electrodes that do not require refillingDouble junction made of porous sintered polyethyleneIntegrated temperature sensor Environmentally friendly design made from bio-based plasticSupplied with calibration and ionic strength adjustment solutionsRobust housing made of polycarbonate and PVCLow maintenance, simply rinse and sealWaterproof according to IP67Linearity in measurement range:The range where the calibration curve has linearity is called the measurement range. When lower concentration is measured where the linearity is not established, perform calibration at two points in the lower concentration range.Influence of pH:The impact of the pH may cause a decrease in the slope of the ion selective electrode, or parallel shifting of the calibration curve. To prevent these effects, set the pH to an appropriate value in advance and keep it constant.Interfering ions:Ion selective electrodes have good selectivity with respect to the ions to be measured, but they may react to the other ions. When using the ion electrode method, it is important to know the effects of coexistent ions and take measures to avoid them. Interfering ions may form compounds with poor solubility or may form complex salts with the structure material of the ion selective membrane, these may to have a significant impact on the measured value.Conditioning:An electrode is conditioned by soaking it in a standard solution for 1 hour or longer. Use a standard solution whose concentration is 100 mg/L or more.In the following cases, perform conditioning of the electrode before calibration.• Before the first use.• Before use after storage for 2 weeks or longer.• If the electrode is less responsive.Calibration:Always calibrate with at least 2 calibration solutions which are 1 decade apart and bracket the expected measurement value.Use fresh calibration solutions and do not re-use them.• Below 10 ppm (mg/L)First solution between 1 and 10ppmSecond solution between 10 and 50 ppm• Between 10 and 100 ppm (mg/L)First solution between 10 and 100ppmSecond solution between 100 and 1000 ppm• Above 100 ppm (mg/L)First solution between 100 and 1000ppmSecond solution above 1000 ppmFurther information can be found in the data sheets in the download area of the store Manufacturer article number: 3200986784 (300-NO3-C)
The Horiba LAQUA 300 BNC adapter is designed to act as an adapter for connecting an ion-selective electrode to the corresponding Smart Sensor module, which is fitted with a cable for connection to a HORIBA Laqua 300 series analyser. HORIBA BNC Adapter 300-BNC – Maximum flexibility for your HORIBA Laqua WQ300 analysers The HORIBA BNC Adapter 300-BNC is the ideal solution if you wish to flexibly expand your HORIBA Laqua WQ300 analysers and easily connect a wide variety of electrodes for immediate use. Whether in the laboratory, in water analysis or in industrial quality control – with this adapter, you can create a universal connection between the measuring instrument and the electrode, significantly expanding the range of applications for your measurement technology. Universal compatibility – Greater freedom in electrode selection With the HORIBA 300-BNC Adapter, you are no longer restricted to manufacturer-specific sensors. The adapter stands out because it can connect not only HORIBA-specific electrodes but also electrodes from other manufacturers, provided they have a BNC connector. The inclusion of a second input in the form of a RCA connector also enables the transmission of temperature data, supporting temperature-compensated measurement and display. Compatibility includes: 3-in-1 / combination pH electrodes and the pH sensor heads 300PH-2 / 300PH-5 3-in-1 / combination ORP electrodes and the ORP sensor head 300-O-2 Combination ion-selective electrodes (ISEs) and the ion sensor head 300-I-2 Thanks to an additional phono/RCA connector, temperature data can also be transmitted – for precise, temperature-compensated measurements. Which Horiba ion-selective electrodes is the adapter compatible with? 895882 Horiba 6560S-10C, chloride ion (Cl-) electrode 895883 Horiba 6561S-10C, fluoride ion (F-) electrode 895880 Horiba 5002S-10C, Ammonia (NH3) ion electrode with 3x membrane cap Your benefits at a glance Extended measurement capabilities: Use a wide variety of electrodes and measure a multitude of parameters – from pH and redox to specific ions. Manufacturer-independent flexibility: Choose the best electrode for your application – regardless of the manufacturer. Precise measurement results: Thanks to temperature compensation, you obtain reliable and reproducible results, even under changing conditions. Easy to use: The adapter allows electrodes to be connected quickly and easily to the WQ300 series measuring instruments. This saves time and optimises use in the laboratory and in the field. Quick connection, secure fit and ready for immediate use – ideal for laboratory and field use. Typical applications The HORIBA BNC Adapter 300-BNC is perfect for: Water analysis & environmental monitoring Research & development laboratories Food and beverage industry Chemical and pharmaceutical industry Quality assurance & production control Whether you are measuring pH values, determining redox potentials or analysing ion concentrations – this adapter turns your measuring instrument into a universal analysis platform. It is particularly useful for users who need a flexible solution to carry out a wide range of measurements with their existing HORIBA WQ300 measuring instruments. The 300-BNC adapter significantly expands the range of applications for the WQ300 series and enables cross-manufacturer compatibility in the field of electrochemical measurements. Why buy the HORIBA 300-BNC adapter? If you already own a HORIBA Laqua WQ300 meter, this adapter is an essential accessory for: continuing to use your existing electrodes saving on the cost of new sensor systems significantly expanding your measurement capabilities The HORIBA 300-BNC adapter transforms your HORIBA Laqua WQ300 series analysers into an open and flexible measurement system for a wide range of applications. Benefit from maximum compatibility, precise measurement results and easy integration into existing measurement processes.
300-2C2C, 2-cell conductivity sensor cartridge, stainless steel, K=0.1 0.01 to 500µS/cm to 2000 mS/cmManufacturer article number: 3200820579
300-4C-C, 4 cell conductivity sensor cartridge, epoxy, carbon body, 10µS/cm to 2000 mS/cmManufacturer article number: 3200780928
Optical dissolved oxygen sensor with hard moulded 2m or 5m cable including a membrane cap. Manufacturer Part Nr. 3200780940 (2 metres = 300-D-2) 3200780942 (5 metres = 300-D-5)
Optical dissolved oxygen sensor with hard moulded 2m or 5m cable including a membrane cap. Manufacturer Part Nr. 3200780940 (2 metres = 300-D-2) 3200780942 (5 metres = 300-D-5)
The HORIBA Dissolved Oxygen Sensor Cap (300-D-M) is an essential component for performing precise and reliable dissolved oxygen measurements in aqueous environments. This replacement cap is designed for use with HORIBA DO sensors models 300-D-2 and 300-D-5. It is the ideal solution for ensuring the measurement accuracy and longevity of your oxygen meter. Advantages of the HORIBA Dissolved Oxygen Sensor Cap Extended Measurement Range: The sensor cap allows for comprehensive dissolved oxygen measurements, making it suitable for a wide variety of applications, from environmental monitoring to industrial processes. Adaptability to Environmental Conditions: With its operating temperature range, it can be used for measurements in diverse aqueous environments, from cool natural waters to warmer industrial process waters. Durable Material: Made from PVC and PMMA, the sensor cap offers high resistance to chemical exposure and mechanical stress, ensuring durability in challenging measurement conditions. Easy Installation: The sensor cap can be replaced quickly and easily, reducing maintenance time and improving operational efficiency. Quick Guide to Replacing the Sensor Cap Remove the old cap: Detach the existing sensor cap from the DO sensor to make room for the new one. Attach the new cap: Secure the new sensor cap to the DO sensor so it can be quickly put back into service. Set the parameters: Enter the specific membrane parameters of the new cap into the meter to optimize measurement accuracy. Calibration process: Use the dedicated calibration function (“CAL in cap replacement”) to fine-tune the measurements with the new cap. Note: The detailed procedure for setting the membrane parameters and performing calibration is described in the device’s user manual. Following these steps ensures your meter is promptly and efficiently configured for the new sensor cap, maintaining accurate measurements over time. For anyone who depends on precise dissolved oxygen measurements, the HORIBA Dissolved Oxygen Sensor Cap (300-D-M) is indispensable. With its robust design, extended measurement range, and ease of use, it greatly enhances the reliability and service life of your HORIBA oxygen meter. Replacement DO cap for 300-D-2 and 300-D-5Manufacturer article number: 3200781554
300-O-C ORP sensor cartridge Manufacturer article number: 3200922104
300-P-C pH sensor cartridgeManufacturer article number: 3200786363