| Width | 10,5 cm |
| Height | 3,5 cm |
| Length | 16,5 cm |
| Weight | 0,0 kg |
| Country of origin | DE |
| Customs tariff number | 90262020 |
| Eingangsdruck | 0 bis 2,5 bar Relativdruck |
| Prozessanschluss Verschraubung | G 1/4 |
JUMO MIDAS C08
€230.50
Please log in to receive your conditions.
Payment methods
Request individual offer (from 5 pcs.)
For larger order quantities, we will be happy to prepare an individual offer for you.
(Login for quotation) The entered number of pieces will be taken into account when creating the quotation.
Delivery & Shipping
- Standard shipping: 3–5 business days within Germany
- Express shipping available on request
- International delivery to EU and Switzerland
- No shipment of Heyl products to Spain, France and Portugal
- Dangerous goods shipping according to ADR regulations
- 3% online discount on HEYL, HORIBA, JUMO and MILWAUKEE products
Personal consultation
Our experts will be happy to advise you on water treatment, measurement technology and sterile processing.
Technical consulting for industry, laboratory and building technology — your specialist for water analysis and process water treatment.
Contact formQuick info
| Width | 10,5 cm |
| Height | 3,5 cm |
| Length | 16,5 cm |
| Weight | 0,0 kg |
| Country of origin | DE |
| Customs tariff number | 90262020 |
| Eingangsdruck | 0 bis 2,5 bar Relativdruck |
| Prozessanschluss Verschraubung | G 1/4 |
Product information "JUMO MIDAS C08"
Pressure Transmitter with Relative Pressure from 0 to 2.5 bar at the Input and 4 to 20 mA at the Output with Process Connection G ¼ DIN EN 837
JUMO MIDAS C08 – OEM Pressure Transmitter Basic Type: 401002/000-456-405-502-20-601-61/000
The JUMO MIDAS C08 is an OEM pressure transmitter for reliable measurement of 0 to 2.5 bar relative pressure. With a 4 to 20 mA two-wire output, G 1/4 process connection and robust design, this variant is particularly suitable for machinery, compressors, building services and industrial pneumatics.
The JUMO MIDAS C08 is designed for OEM applications where relative pressure must be measured reliably over the long term. This variant measures 0 to 2.5 bar relative pressure and provides the signal as 4 to 20 mA in two-wire operation. With process connection G 1/4 according to DIN EN 837 and cable socket according to DIN EN 175301-803, Form A, this version is designed for solid and practical integration into technical systems.
Technical Data
- Design: JUMO MIDAS C08 – OEM Pressure Transmitter Basic
- Input: 0 to 2.5 bar relative pressure
- Output: 4 to 20 mA, two-wire
- Process connection: G 1/4 DIN EN 837
- Material process connection: CrNi (stainless steel)
- Material seal: CrNi (stainless steel)
- Electrical connection: Cable socket DIN EN 175301-803, Form A
- Type addition: none
Advantages and Technical Features of the JUMO Pressure Transmitter
- suitable for relative pressure measurements from 0 to 2.5 bar
- high long-term stability below 0.2 %
- robust design for applications exposed to vibration
- extended temperature compensation range from -20 to +100 °C
Especially in the lower pressure range from 0 to 2.5 bar, this variant is particularly suitable for applications where smaller relative pressures must be monitored precisely and remain stable over the long term. The high long-term stability of below 0.2 % supports reliable measurement over extended operating periods. This is especially important where pressure values must not only be recorded temporarily but monitored continuously.
Another advantage is the robust design for more demanding operating conditions. The vibration resistance is 2.5 times higher than the industry standard. This makes the pressure transmitter suitable for applications with increased vibration loads, such as those found in machinery and plant engineering, compressors or commercial vehicles.
The process connection and seal are made of CrNi stainless steel, further emphasizing the durable construction. The pressure transmitter is designed for gaseous and liquid media and is therefore suitable for a wide range of technical applications. This is complemented by the extended temperature compensation range from -20 to +100 °C.
Typical Applications
- machinery and plant engineering
- compressors
- building services
- industrial pneumatics
- commercial vehicles
| Position | Code | Description | Note |
|---|---|---|---|
| (1) Basic type | |||
| Basic type | 401002/000 |
JUMO MIDAS C08 – OEM Pressure Transmitter – Basic | |
| (2) Input | |||
| Input | 455 | 0 to 1.6 bar gauge pressure | |
| Input | 456 | 0 to 2.5 bar gauge pressure | |
| Input | 457 | 0 to 4 bar gauge pressure | |
| Input | 458 | 0 to 6 bar gauge pressure | |
| Input | 459 | 0 to 10 bar gauge pressure | |
| Input | 460 | 0 to 16 bar gauge pressure | |
| Input | 461 | 0 to 25 bar gauge pressure | |
| Input | 462 | 0 to 40 bar gauge pressure | |
| Input | 463 | 0 to 60 bar gauge pressure | |
| Input | 479 | -1 to +0.6 bar gauge pressure | |
| Input | 480 | -1 to +1.5 bar gauge pressure | |
| Input | 481 | -1 to +3 bar gauge pressure | |
| Input | 482 | -1 to +5 bar gauge pressure | |
| Input | 483 | -1 to +9 bar gauge pressure | |
| Input | 484 | -1 to +15 bar gauge pressure | |
| Input | 485 | -1 to +24 bar gauge pressure | |
| Input | 999 | Special measuring range, gauge pressure | |
| (3) Output | |||
| Output | 405 | 4 to 20 mA, two-wire | |
| Output | 412 | 0.5 to 4.5 V, three-wire | |
| Output | 415 | 0 to 10 V, three-wire | |
| Output | 418 | 1 to 5 V, three-wire | |
| Output | 420 | 1 to 6 V, three-wire | |
| (4) Process connection | |||
| Process connection | 502 | G 1/4 DIN EN 837 | |
| Process connection | 504 | G 1/2 DIN EN 837 | |
| Process connection | 511 | 1/4-18 NPT DIN EN 837 | |
| Process connection | 521 | G 1/4 DIN 3852-11 | |
| Process connection | 562 | 7/16-20 UNF | |
| (5) Process connection material | |||
| Material | 20 | CrNi (stainless steel) | |
| (6) Seal material | |||
| Seal | 600 | EPDM | |
| Seal | 601 | FKM (standard) | |
| Seal | 602 | CR | |
| Seal | 604 | FFKM | |
| Seal | 609 | NBR | |
| (7) Electrical connection | |||
| Electrical connection | 11 |
Fixed cable | Standard length 2 m, other lengths available on request |
| Electrical connection | 23 | Quickon | |
| Electrical connection | 36 | M12 × 1 circular connector | |
| Electrical connection | 53 | Bayonet connector DIN 72585 | |
| Electrical connection | 61 | DIN EN 175301-803 cable socket, Form A | |
| (8) Type extras | |||
| Type extra | 000 | none | |
| Type extra | 061 | UL approval | |
| Type extra | 591 | Restrictor in pressure channel | |
| Type extra | 624 | Oil- and grease-free | |
| Type extra | 630 | Enlarged pressure channel | See footnote |
| Type extra | 876 | Test report | |
| Type extra | 954 | Technical passport | |
Note:
Type extra 630 (enlarged pressure channel Ø 8 mm)
is only available in combination with the process connections
1/4-18 NPT and G 1/4 as well as the
FKM seal (code 601).
|
|||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | |
|---|---|---|---|---|---|---|---|---|
| Ordering code | 401002/000 |
- |
- |
- |
- |
- |
- |
/ , ...a |
| Ordering example | 401002/000 |
460 |
412 |
504 |
20 |
600 |
36 |
591 |
a Multiple type extras are specified consecutively and
separated by commas, e.g.
/591,624,876.
|
||||||||
Frequently Asked Questions
It is suitable for pressure measurement in machinery, plant systems, compressors, and building services engineering.
The sensor outputs a 4–20 mA signal in two-wire mode.
Yes. Quickon rapid-clamping technology makes installation significantly easier.
Yes. It is designed for stable, long-term measurement during continuous operation.
It is highly vibration-resistant and suitable for demanding industrial environments.
Yes, it is versatile and suitable for many standard applications.
No, installation is quick and easy.
No, it operates reliably and requires minimal maintenance.
It responds rapidly and quickly provides current measured values.
It offers good value for money and is easy to use.
|
General Reference conditions |
DIN 16086 and DIN EN 60770 |
|
Sensor Measuring principle Permissible load changes |
Thick film on ceramic body (piezoresistiv) > 10 Millionen, 0 until 100 % Measuring range |
|
Mounting position Calibrationslage |
any Device standing vertically, process connection at the bottom |
Measuring range and accuracy
|
Measuring range |
Linearity
% MSPf |
Accuracy at |
Long-term stability % MSP per annum |
Overload capability bar |
Burst pressure bar |
||
|
20 °Cd % MSP |
-10 to +85 °Ce % MSP |
-20 to +100 °Ce % MSP |
|||||
|
0 to 1.6 bar relative pressure |
0,25 |
0,5 |
0,65 |
1 |
0,2 |
6 |
12 |
|
0 to 2.5 bar relative pressure |
6 |
12 |
|||||
|
0 to 4 bar relative pressure |
0,35 |
0,5 |
12 |
25 |
|||
|
0 to 6 bar relative pressure |
12 |
25 |
|||||
|
0 to 10 bar relative pressure |
20 |
38 |
|||||
|
0 to 16 bar relative pressure |
50 |
75 |
|||||
|
0 to 25 bar relative pressure |
50 |
75 |
|||||
|
0 to 40 bar relative pressure |
120 |
200 |
|||||
|
0 to 60 bar relative pressure |
120 |
200 |
|||||
|
-1 to +0.6 bar relative pressure |
0,5 |
0,65 |
6 |
12 |
|||
|
-1 to +1.5 bar relative pressure |
6 |
12 |
|||||
|
-1 to +3 bar relative pressure |
0,35 |
0,5 |
12 |
25 |
|||
|
-1 to +5 bar relative pressure |
12 |
25 |
|||||
|
-1 to +9 bar relative pressure |
20 |
38 |
|||||
|
-1 to +15 bar relative pressure |
50 |
75 |
|||||
|
-1 to +24 bar relative pressure |
50 |
75 |
|||||
a Linearity after limit point setting
b Reference conditions EN 61298-1
c All pressure transmitters are vacuum-proof.
d Includes: linearity, hysteresis, repeatability, deviation from initial and full scale
e Includes: linearity, hysteresis, repeatability, deviation of initial and full scale range, thermal influence on starting range and span
f MSP = Span
Exit
|
Analog |
Other outputs are available on request. |
|
Current |
4 to 20 mA, Two-wire |
|
Voltage |
DC 0,5 to 4,5 V, Three-wire, ratiometric 10 to 90 % of the power supply |
|
|
DC 0 to 10 V, Three-wire |
|
|
DC 1 bis 5 V, Three-wire |
|
|
DC 1 bis 6 V, Three-wire |
|
Jump Response T90 |
£ 2 ms |
|
Burde Current Voltage (Load connected against "0 V/S-") |
RL £ (UB - 8 V) ÷ 0,02 A (W) at 4 to 20 mA, two-wire RL ³ 5 kW at DC 0.5 to 4.5 V, three-wire RL ³ 10 kW at DC 0 to 10 V, three-wire RL ³ 10 kW at DC 1 to 5 V, three-wire RL ³ 10 kW at DC 1 to 6 V, three-wire |
|
|
|
Mechanical Properties
|
Materials |
|
|
Process connection |
Stainless Steel 304 |
|
Gasket 600 (internal) |
EPDM |
|
Gasket 601 (internal) |
FKM, standard |
|
Gasket 602 (internal) |
CR |
|
Gasket 604 (internal) |
FFKM |
|
Gasket 609 (internal) |
NBR |
|
Process connection G 1/4 (externa) |
FKM |
|
Sensor Case |
Ceramics Al2O3 96 % Stainless steel 304 |
|
fixed cable |
PBT-GF30, PVC |
|
QUICKON |
PBT-GF30 |
|
Round plug M12 × 1 |
PBT-GF30, Edelstahl 303 L |
|
Bayonet stecker |
PBT-GF30 |
|
Electrical connector |
PBT-GF30, PA, Silikon |
|
Gewicht |
70 g with process connection G 1/4 |
a Pay attention to the resistance of the selected sealing material!
Environmental impact
|
Medium temperature with electrical connection |
|
|
fixed cable |
-20 to +125 °C |
|
Round plugs M12 × 1 |
-20 to +125 °C |
|
Bayonet stecker |
-20 to +125 °C |
|
Electrical connector |
-20 to +125 °C |
|
Ambient temperature with electrical connection |
|
|
fixed cable |
-20 to +100 °C limited operation at ambient temperature -30 °C; Use only stationary, Kabelbruchgefahr |
|
Round plugs M12 × 1 |
-20 to +100 °C |
|
Bayonet stecker |
-20 to +100 °C |
|
Electrical connector |
-20 to +100 °C |
|
Storage temperature with electrical connection |
|
|
fixed cable |
-30 to +100 °C |
|
Round plugs M12 × 1 |
-40 to +100 °C |
|
Bayonet stecker |
-40 to +100 °C |
|
Electrical connector |
-40 to +100 °C |
|
zulässige Luftfeuchtigkeit Betrieb Lagerung |
100 % relative humidity incl. condensation on the outer shell of the device 90 % relative humidity without condensation |
|
Permissible mechanical stress Vibration Resistance Shock Resistance |
50 g at 10 to 2000 Hz, according to IEC 60068-2-6 50 g for 3 ms, 100 g for 2 ms, according to IEC 60068-2-27 |
|
electromagnetic compatibility (EMV) Emission Stability |
nach EN 61326-2-3 Class Ba Industrial Requirement |
|
Protection |
after EN 60529 |
|
for electrical connection |
|
|
fixed cable |
IP67 |
|
QUICKONb |
IP67 |
|
Round plugs M12 × 1c |
IP67 |
|
Baonet steckerc |
IP67 |
|
Cable boxec, d |
IP65 |
a The product is suitable for industrial use as well as for household and small businesses.
b Connecting cable diameter minimum 3.5 mm, maximum 6 mm
c The degree of protection can only be achieved with a suitable, mounted counterpart.
d Connecting cable diameter minimum 6 mm, maximum 8 mm
Electric Dating
|
Power supply UB |
Ripple: The voltage peaks must not exceed or fall below the specified values of the power supply! |
|
4 to 20 mA, Two-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
DC 0,5 to 4,5 V, Three-wire |
DC 3 to 5,25 V, Nominal power supply DC 5 V, ratiometric output 10 to 90 % of the power supply |
|
DC 0 to 10 V, Three-wire |
DC 11,5 to 30 V, Nominal power supply DC 24 V |
|
DC 1 to 5 V, Three-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
DC 1 to 6 V, Three-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
Current consumption incl. load |
£ 25 mA £ 3 mA £ 3 mA £ 3 mA £ 3 mA |
|
4 to 20 mA, Two-wire |
|
|
DC 0,5 to 4,5 V, Three-wire |
|
|
DC 0 to 10 V, Three-wire |
|
|
DC 1 to 5 V, Three-wire |
|
|
DC 1 to 6 V, Three-wire |
|
|
Reverse polarity protection |
yes |
|
Circuit Requirement |
SELV The device must be supplied with an electrical circuit that meets the requirements for "energy-limited circuits" of EN 61010-1. |
Approvals and test marks
|
EAC Testing Laboratory Certificates/Inspection Numbers Test Basis applies to: |
«Промтехконтроль» ЕАЭС N RU Д-DE.PA01.В.80830/21 TR TS 020/2011 Typ 401002 |
|
UL |
|
|
Checkpoint |
Underwriter Laboratories |
|
Certificates/Verification Numbers |
E201387 |
|
Test basis |
UL 61010-1 (3. Ed.), CAN/CSA-22.2 No. 61010-1 (3. Ed.) |
|
applies to: |
Type Suffix 061 |