JUMO MIDAS C08
€230.50*
Please log in to receive your conditions.
Available in 28 days, delivery time 1-2 days
(Login for quotation) The entered number of pieces will be taken into account when creating the quotation.
Product information "JUMO MIDAS C08"
Pressure transmitter JUMO MIDAS C08 for 0 to 16 bar relative pressure at the input and 4 to 20 mA output signal with G ½ DIN EN 837 process connection
JUMO MIDAS C08 – OEM pressure transmitter Basic Type: 401002/000-460-405-504-20-601-61/000
This OEM pressure transmitter is designed for industrial relative pressure measurement in an extended pressure range. With a 4–20 mA output, robust stainless steel construction, and high stability, it is suitable for mechanical engineering, plant engineering, and mobile applications with dynamic loads.
The JUMO MIDAS C08 is an OEM pressure transmitter for measuring relative pressure in the range from 0 to 16 bar. This version is intended for applications where a higher pressure range within the MIDAS series must be monitored reliably and continuously. The output signal is provided as 4 to 20 mA in a two-wire configuration and enables direct integration into industrial control and automation systems.
Technical data
- Input: 0 to 16 bar relative pressure
- Output: 4 to 20 mA, two-wire
- Process connection: G 1/2 DIN EN 837
- Material of process connection: CrNi (stainless steel)
- Material of seal: CrNi (stainless steel)
- Electrical connection: Connector DIN EN 175301-803, Form A
Advantages and technical features
- Measuring range up to 16 bar for increased pressure requirements
- Stable long-term measurement due to < 0.2 % drift
- Suitable for gaseous and liquid media
- Robust industrial design with CrNi stainless steel
- High vibration resistance (2.5× industrial standard)
- Reliable under vibrations and dynamic loads
Inside, a ceramic-based sensor element is used, designed for stable and long-term consistent signal acquisition. The specified long-term stability below 0.2 % ensures that measurement values remain precise and reliable even over extended operating periods.
This version is suitable for use with gaseous and liquid media and therefore covers a wide range of industrial applications. Thanks to the extended temperature compensation range from -20 to +100 °C, measurement performance remains stable even under changing ambient conditions.
Mechanically, the pressure transmitter is designed for industrial applications. The G 1/2 process connection according to DIN EN 837 allows robust and standardized integration into existing systems. The wetted parts are made of CrNi stainless steel, ensuring high resistance and a long service life.
The electrical connection is made via a connector according to DIN EN 175301-803, Form A, ensuring a standardized and secure connection.
The design is intended for OEM and series applications where process reliability, easy integration, and dependable continuous operation are essential.
Typical areas of application
- Mechanical and plant engineering
- Compressors and pressure systems
- Industrial pneumatics
- Building technology and supply systems
- Commercial vehicles and mobile machinery
| Position | Code | Description | Note |
|---|---|---|---|
| (1) Basic type | |||
| Basic type | 401002/000 |
JUMO MIDAS C08 – OEM Pressure Transmitter – Basic | |
| (2) Input | |||
| Input | 455 | 0 to 1.6 bar gauge pressure | |
| Input | 456 | 0 to 2.5 bar gauge pressure | |
| Input | 457 | 0 to 4 bar gauge pressure | |
| Input | 458 | 0 to 6 bar gauge pressure | |
| Input | 459 | 0 to 10 bar gauge pressure | |
| Input | 460 | 0 to 16 bar gauge pressure | |
| Input | 461 | 0 to 25 bar gauge pressure | |
| Input | 462 | 0 to 40 bar gauge pressure | |
| Input | 463 | 0 to 60 bar gauge pressure | |
| Input | 479 | -1 to +0.6 bar gauge pressure | |
| Input | 480 | -1 to +1.5 bar gauge pressure | |
| Input | 481 | -1 to +3 bar gauge pressure | |
| Input | 482 | -1 to +5 bar gauge pressure | |
| Input | 483 | -1 to +9 bar gauge pressure | |
| Input | 484 | -1 to +15 bar gauge pressure | |
| Input | 485 | -1 to +24 bar gauge pressure | |
| Input | 999 | Special measuring range, gauge pressure | |
| (3) Output | |||
| Output | 405 | 4 to 20 mA, two-wire | |
| Output | 412 | 0.5 to 4.5 V, three-wire | |
| Output | 415 | 0 to 10 V, three-wire | |
| Output | 418 | 1 to 5 V, three-wire | |
| Output | 420 | 1 to 6 V, three-wire | |
| (4) Process connection | |||
| Process connection | 502 | G 1/4 DIN EN 837 | |
| Process connection | 504 | G 1/2 DIN EN 837 | |
| Process connection | 511 | 1/4-18 NPT DIN EN 837 | |
| Process connection | 521 | G 1/4 DIN 3852-11 | |
| Process connection | 562 | 7/16-20 UNF | |
| (5) Process connection material | |||
| Material | 20 | CrNi (stainless steel) | |
| (6) Seal material | |||
| Seal | 600 | EPDM | |
| Seal | 601 | FKM (standard) | |
| Seal | 602 | CR | |
| Seal | 604 | FFKM | |
| Seal | 609 | NBR | |
| (7) Electrical connection | |||
| Electrical connection | 11 |
Fixed cable | Standard length 2 m, other lengths available on request |
| Electrical connection | 23 | Quickon | |
| Electrical connection | 36 | M12 × 1 circular connector | |
| Electrical connection | 53 | Bayonet connector DIN 72585 | |
| Electrical connection | 61 | DIN EN 175301-803 cable socket, Form A | |
| (8) Type extras | |||
| Type extra | 000 | none | |
| Type extra | 061 | UL approval | |
| Type extra | 591 | Restrictor in pressure channel | |
| Type extra | 624 | Oil- and grease-free | |
| Type extra | 630 | Enlarged pressure channel | See footnote |
| Type extra | 876 | Test report | |
| Type extra | 954 | Technical passport | |
Note:
Type extra 630 (enlarged pressure channel Ø 8 mm)
is only available in combination with the process connections
1/4-18 NPT and G 1/4 as well as the
FKM seal (code 601).
|
|||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | |
|---|---|---|---|---|---|---|---|---|
| Ordering code | 401002/000 |
- |
- |
- |
- |
- |
- |
/ , ...a |
| Ordering example | 401002/000 |
460 |
412 |
504 |
20 |
600 |
36 |
591 |
a Multiple type extras are specified consecutively and
separated by commas, e.g.
/591,624,876.
|
||||||||
Frequently Asked Questions
It is suitable for pressure measurement in machinery, plant systems, compressors, and building services engineering.
The sensor outputs a 4–20 mA signal in two-wire mode.
Yes. Quickon rapid-clamping technology makes installation significantly easier.
Yes. It is designed for stable, long-term measurement during continuous operation.
It is highly vibration-resistant and suitable for demanding industrial environments.
Yes, it is versatile and suitable for many standard applications.
No, installation is quick and easy.
No, it operates reliably and requires minimal maintenance.
It responds rapidly and quickly provides current measured values.
It offers good value for money and is easy to use.
Dimensions
| Height | 3,5 cm |
|---|---|
| Length | 11 cm |
| Width | 5,5 cm |
Weight
| Weight | 145 g |
|---|
Other attributes
| Country of origin | DE |
|---|---|
| Customs tariff number | 90262020 |
| Eingangsdruck | 0 bis 16 bar Relativdruck |
| Prozessanschluss Verschraubung | G 1/2 |
|
General Reference conditions |
DIN 16086 and DIN EN 60770 |
|
Sensor Measuring principle Permissible load changes |
Thick film on ceramic body (piezoresistiv) > 10 Millionen, 0 until 100 % Measuring range |
|
Mounting position Calibrationslage |
any Device standing vertically, process connection at the bottom |
Measuring range and accuracy
|
Measuring range |
Linearity
% MSPf |
Accuracy at |
Long-term stability % MSP per annum |
Overload capability bar |
Burst pressure bar |
||
|
20 °Cd % MSP |
-10 to +85 °Ce % MSP |
-20 to +100 °Ce % MSP |
|||||
|
0 to 1.6 bar relative pressure |
0,25 |
0,5 |
0,65 |
1 |
0,2 |
6 |
12 |
|
0 to 2.5 bar relative pressure |
6 |
12 |
|||||
|
0 to 4 bar relative pressure |
0,35 |
0,5 |
12 |
25 |
|||
|
0 to 6 bar relative pressure |
12 |
25 |
|||||
|
0 to 10 bar relative pressure |
20 |
38 |
|||||
|
0 to 16 bar relative pressure |
50 |
75 |
|||||
|
0 to 25 bar relative pressure |
50 |
75 |
|||||
|
0 to 40 bar relative pressure |
120 |
200 |
|||||
|
0 to 60 bar relative pressure |
120 |
200 |
|||||
|
-1 to +0.6 bar relative pressure |
0,5 |
0,65 |
6 |
12 |
|||
|
-1 to +1.5 bar relative pressure |
6 |
12 |
|||||
|
-1 to +3 bar relative pressure |
0,35 |
0,5 |
12 |
25 |
|||
|
-1 to +5 bar relative pressure |
12 |
25 |
|||||
|
-1 to +9 bar relative pressure |
20 |
38 |
|||||
|
-1 to +15 bar relative pressure |
50 |
75 |
|||||
|
-1 to +24 bar relative pressure |
50 |
75 |
|||||
a Linearity after limit point setting
b Reference conditions EN 61298-1
c All pressure transmitters are vacuum-proof.
d Includes: linearity, hysteresis, repeatability, deviation from initial and full scale
e Includes: linearity, hysteresis, repeatability, deviation of initial and full scale range, thermal influence on starting range and span
f MSP = Span
Exit
|
Analog |
Other outputs are available on request. |
|
Current |
4 to 20 mA, Two-wire |
|
Voltage |
DC 0,5 to 4,5 V, Three-wire, ratiometric 10 to 90 % of the power supply |
|
|
DC 0 to 10 V, Three-wire |
|
|
DC 1 bis 5 V, Three-wire |
|
|
DC 1 bis 6 V, Three-wire |
|
Jump Response T90 |
£ 2 ms |
|
Burde Current Voltage (Load connected against "0 V/S-") |
RL £ (UB - 8 V) ÷ 0,02 A (W) at 4 to 20 mA, two-wire RL ³ 5 kW at DC 0.5 to 4.5 V, three-wire RL ³ 10 kW at DC 0 to 10 V, three-wire RL ³ 10 kW at DC 1 to 5 V, three-wire RL ³ 10 kW at DC 1 to 6 V, three-wire |
|
|
|
Mechanical Properties
|
Materials |
|
|
Process connection |
Stainless Steel 304 |
|
Gasket 600 (internal) |
EPDM |
|
Gasket 601 (internal) |
FKM, standard |
|
Gasket 602 (internal) |
CR |
|
Gasket 604 (internal) |
FFKM |
|
Gasket 609 (internal) |
NBR |
|
Process connection G 1/4 (externa) |
FKM |
|
Sensor Case |
Ceramics Al2O3 96 % Stainless steel 304 |
|
fixed cable |
PBT-GF30, PVC |
|
QUICKON |
PBT-GF30 |
|
Round plug M12 × 1 |
PBT-GF30, Edelstahl 303 L |
|
Bayonet stecker |
PBT-GF30 |
|
Electrical connector |
PBT-GF30, PA, Silikon |
|
Gewicht |
70 g with process connection G 1/4 |
a Pay attention to the resistance of the selected sealing material!
Environmental impact
|
Medium temperature with electrical connection |
|
|
fixed cable |
-20 to +125 °C |
|
Round plugs M12 × 1 |
-20 to +125 °C |
|
Bayonet stecker |
-20 to +125 °C |
|
Electrical connector |
-20 to +125 °C |
|
Ambient temperature with electrical connection |
|
|
fixed cable |
-20 to +100 °C limited operation at ambient temperature -30 °C; Use only stationary, Kabelbruchgefahr |
|
Round plugs M12 × 1 |
-20 to +100 °C |
|
Bayonet stecker |
-20 to +100 °C |
|
Electrical connector |
-20 to +100 °C |
|
Storage temperature with electrical connection |
|
|
fixed cable |
-30 to +100 °C |
|
Round plugs M12 × 1 |
-40 to +100 °C |
|
Bayonet stecker |
-40 to +100 °C |
|
Electrical connector |
-40 to +100 °C |
|
zulässige Luftfeuchtigkeit Betrieb Lagerung |
100 % relative humidity incl. condensation on the outer shell of the device 90 % relative humidity without condensation |
|
Permissible mechanical stress Vibration Resistance Shock Resistance |
50 g at 10 to 2000 Hz, according to IEC 60068-2-6 50 g for 3 ms, 100 g for 2 ms, according to IEC 60068-2-27 |
|
electromagnetic compatibility (EMV) Emission Stability |
nach EN 61326-2-3 Class Ba Industrial Requirement |
|
Protection |
after EN 60529 |
|
for electrical connection |
|
|
fixed cable |
IP67 |
|
QUICKONb |
IP67 |
|
Round plugs M12 × 1c |
IP67 |
|
Baonet steckerc |
IP67 |
|
Cable boxec, d |
IP65 |
a The product is suitable for industrial use as well as for household and small businesses.
b Connecting cable diameter minimum 3.5 mm, maximum 6 mm
c The degree of protection can only be achieved with a suitable, mounted counterpart.
d Connecting cable diameter minimum 6 mm, maximum 8 mm
Electric Dating
|
Power supply UB |
Ripple: The voltage peaks must not exceed or fall below the specified values of the power supply! |
|
4 to 20 mA, Two-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
DC 0,5 to 4,5 V, Three-wire |
DC 3 to 5,25 V, Nominal power supply DC 5 V, ratiometric output 10 to 90 % of the power supply |
|
DC 0 to 10 V, Three-wire |
DC 11,5 to 30 V, Nominal power supply DC 24 V |
|
DC 1 to 5 V, Three-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
DC 1 to 6 V, Three-wire |
DC 8 to 30 V, Nominal power supply DC 24 V |
|
Current consumption incl. load |
£ 25 mA £ 3 mA £ 3 mA £ 3 mA £ 3 mA |
|
4 to 20 mA, Two-wire |
|
|
DC 0,5 to 4,5 V, Three-wire |
|
|
DC 0 to 10 V, Three-wire |
|
|
DC 1 to 5 V, Three-wire |
|
|
DC 1 to 6 V, Three-wire |
|
|
Reverse polarity protection |
yes |
|
Circuit Requirement |
SELV The device must be supplied with an electrical circuit that meets the requirements for "energy-limited circuits" of EN 61010-1. |
Approvals and test marks
|
EAC Testing Laboratory Certificates/Inspection Numbers Test Basis applies to: |
«Промтехконтроль» ЕАЭС N RU Д-DE.PA01.В.80830/21 TR TS 020/2011 Typ 401002 |
|
UL |
|
|
Checkpoint |
Underwriter Laboratories |
|
Certificates/Verification Numbers |
E201387 |
|
Test basis |
UL 61010-1 (3. Ed.), CAN/CSA-22.2 No. 61010-1 (3. Ed.) |
|
applies to: |
Type Suffix 061 |