Skip to main content Skip to search Skip to main navigation

JUMO ecoLine glass shaft pH electrode with salt reserve, S8 Pg13.5 screw head

Article number: 800192
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "JUMO ecoLine glass shaft pH electrode with salt reserve, S8 Pg13.5 screw head"

This electrode is particularly suitable wherever a cost-efficient, proven, and long-life-oriented electrode is required for general aqueous media.

JUMO ecoLine glass shaft pH electrode with salt reservoir, S8 Pg13.5 screw head (type key: 201005/51-18-22-0000-00-120/837, part no.: 00447837)

This JUMO ecoLine glass shaft pH electrode is a reliable choice for pH measurements in general aqueous media. It is designed for users who are looking for an economical, practical, and robust electrode suitable for many standard water applications. The version with salt reservoir is particularly advantageous when the electrode is used under conditions where extended service life is beneficial.

Technical data

  • Design: glass shaft pH electrode
  • Measuring range: pH 0 to 12, short-term up to pH 14
  • Temperature sensor: none
  • Active element: JUMO UW glass
  • Diaphragm: ceramic
  • Electrolyte: polymerized KCl solid electrolyte
  • Reference system: JUMO cartridge reference system
  • Electrical connection: S8 Pg13.5 screw head
  • Immersion length: 120 mm (standard)
  • Type extension: salt reservoir

Advantages and special features

The electrode measures in the pH range from 0 to 12, and for short periods up to pH 14. It is equipped with low-ohmic JUMO UW glass, enabling fast and stable measurement results. The ceramic diaphragm and polymerized KCl solid electrolyte make it suitable for many standard applications in water analysis.

The proven JUMO cartridge reference system ensures that the electrolyte remains free of silver ions over its service life and is less susceptible to certain electrode poisons.

Why choose this electrode?

This version is particularly suitable when a pH electrode for general water applications is required that offers more than a basic standard model. The salt reservoir is especially beneficial in low-ion media or higher flow conditions, as it can extend the electrode’s service life.

For this reason, it is ideal for users seeking a more durable solution for regular operation rather than a basic version without additional type extensions.

With the S8 Pg13.5 screw head and 120 mm immersion length, the electrode fits many common installation situations. An integrated temperature sensor is not available in this series, keeping the focus entirely on reliable pH measurement.

Typical applications

  • drinking water monitoring and water treatment, swimming pools
  • aquarium applications
  • greenhouse and horticulture applications
  • slightly polluted service, process, and wastewater
  • rainwater, pond, and surface water
  • use in portable measuring devices

Not recommended for

  • electroplating wastewater treatment
  • industrial process and wastewater
  • ultrapure water
  • therapy pools
  • biotechnology and sterile processes

Other attributes

Applications Aquaculture and Coral, Aquariums, Beer, Beverages, Environmental, Food, Horticulture, Hydroponics, Pools, Schools, Water Conditioning, Water Treatment, Wine
Technical specifications
Technical specifications Glass-shaft version Model with plastic shaft and clip-on protective cage JUMO BlackLine – version with plastic shaft and fixed protective cage
Shaft material Glass PEI* PPO**
Diaphragm Ceramics glass silk Ceramics
Drainage system plastic cartridge
Temperature range 0 up to 60 °C
Print range*** 0 up to 6 bar
Installation length 120 mm
Electrode head
  • socket head
  • Plug-in head with fixed cable
  • screw head Pg13,5
  • PG13.5 screw-in fitting with fixed cable
In models with a fixed cable, the connection cable is fitted with a kink protector.
Models with a fixed cable have an IP68 rating.
Active component pH Underwater glass (pH 0 to 12, briefly up to pH 14)
Active component: Redox Platinum dome (±2000 mV)
electrolyte Polymerised solid electrolyte
Recommended minimum conductivity of the measured medium Without a salt cellar: 100 µS/cm
With a salt dish: 50 µS/cm
Without a salt cellar: 150 µS/cm
With a salt dish: 100 µS/cm
Without a salt cellar: 100 µS/cm
With a salt dish: 50 µS/cm

* is equivalent to polyetherimide

** corresponds to polyphenylene ether

*** The pressure specifications apply to constant conditions at the installation site; severe pressure surges and fluctuations should be avoided.

Type suffixes

Type suffix Description
KCl container (quiver), model code 052

The base of the KCl container can also be used as a mounting wrench for pH or redox electrodes with a Pg13.5 thread. The recesses on the removable container base fit onto the hexagon of the electrode head. When storing the electrodes, the container must be filled with KCl (not with buffer solution or similar).

Salt reservoir, model code 837

Optionally, the electrode can be fitted with a salt reservoir in the form of four salt rings. This is recommended when using the electrode in media with low ion concentrations or at high flow rates. The salt reservoir serves to extend the service life of the electrode. The rings do not constitute a manufacturing defect (crystallisation).

You can find further pH and redox electrodes in the relevant data sheets in the downloads section.