JUMO hydroTRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct design
€348.10*
Please log in to receive your conditions.
Available in 28 days, delivery time 1-2 days
(Login for quotation) The entered number of pieces will be taken into account when creating the quotation.
Product information "JUMO hydroTRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct design"
Temperature transmitter from JUMO in duct version for measuring humidity, temperature, and CO2 concentration in ventilation systems
JUMO hydroTRANS S30 – Humidity, temperature, and CO₂ transmitter (duct version)
This version of the JUMO hydroTRANS S30 is suitable as a duct transmitter for the simultaneous measurement of temperature, humidity, and CO₂ in ventilation systems. It enables flexible transmission of measured values into building and automation technology and is particularly suitable for demanding climate and process air applications.
It is used for monitoring incoming outside air in building and process systems. The measured values are provided via flexible analog output signals for further processing in automation and building technology systems.
Technical data
- Type: 907043/12
- Basic type extension: RH-T-CO₂
- Version: Standard
- Measuring range: 0 … 95 % RH / -10 … +60 °C / 10,000 ppm CO₂
- Measured parameters: temperature, relative humidity, carbon dioxide (optional)
- Output: 4–20 mA / 0–10 V (combined output configured)
- Interfaces: USB, RS-485
- Type addition: without
Advantages
- Combined measurement of temperature, humidity, and optional CO₂
- Flexible combined output for industrial signal processing
- Easy integration into existing systems
- Optional protection through plastic sinter filter
- Multisensor technology for stable measured values
Typical areas of application
- Ventilation and air conditioning systems
- Building and facility management
- Climate monitoring in industrial plants
- Storage and logistics areas
- Weather-protected ventilation ducts
Frequently Asked Questions
Yes, both values are captured in parallel within the ventilation duct.
Yes, it is designed for easy integration into existing systems.
Via analog signals or digital interfaces such as RS-485.
Yes, it is suitable for demanding climate and process air applications.
No, the device is designed for simple duct mounting.
Yes, an optional sintered plastic filter protects the sensing element.
Other attributes
| Ausgang | 4...20 mA / 0...10 V (Kombiausgang konfiguriert) |
|---|---|
| Customs tariff number | 90258040 |
| Messbereich (Temperatur & relative Feuchte) | 0...95% rF / -10°C...+60°C |
| Messparameter | Kohlenstoffdioxid (CO2), Relative Feuchte, Temperatur |