Skip to main content Skip to search Skip to main navigation

Horiba LAQUAtwin S021 Salt Replacement Sensor for Salt-22 tester

Article number: 896061
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "Horiba LAQUAtwin S021 Salt Replacement Sensor for Salt-22 tester "

The HORIBA LAQUAtwin Pocket Tester series provides a comprehensive solution for fast and precise measurement of water quality parameters directly in the field. To ensure these measurements remain reliable and accurate, regular monitoring of the sensors and, if necessary, replacement with spare sensors is crucial.

These replacement sensors are tailor-made for the HORIBA LAQUAtwin series and cover a wide range of types for various measurements: pH, conductivity, salinity, redox (ORP), as well as ion-selective sensors for sodium, potassium, nitrate, calcium, and fluoride. Each sensor is designed to maximize user-friendliness and accuracy, which HORIBA is renowned for in water quality testing worldwide. HORIBA replacement sensors guarantee users that their devices consistently deliver optimal performance and precise measurements.

Advantages of HORIBA Replacement Sensors

  • Easy Replacement: Sensors can be exchanged quickly, allowing uninterrupted measurement.
  • High Accuracy: Replacement sensors ensure precise and reliable results.
  • Wide Measurement Range: Various sensor types are available to capture a broad spectrum of water quality parameters.
  • Durability: Sensors are designed for long service life, even under challenging conditions.

Sensor Replacement Instructions

Follow these steps to replace the sensor and maintain the longevity and accuracy of your HORIBA LAQUAtwin Pocket Tester:

Removing the Sensor
  1. Turn off the tester.
  2. Lift the sensor tip slightly and pull the sensor away from the device.
  3. Completely detach the sensor from the tester.
Installing the Sensor
  1. Make sure the tester is turned off.
  2. Ensure the waterproof gasket is intact and clean.
  3. Attach the sensor to the tester so that hook “A” on the back of the device fits into hole “a” on the sensor tip.
  4. Make sure the waterproof gasket is not twisted.

Important:

After replacing the sensor, follow the instructions in the user manual of the respective tester to make the device ready for accurate measurements. This typically includes calibration and, if necessary, conditioning.

How can I tell if my sensor is worn out?

Check the sensor condition as follows:

Perform a 2-point calibration. If an error occurs during calibration, this indicates that the sensor has deteriorated. In this case, the sensor should be replaced.

Regular checks and timely replacement of sensors ensure the high quality and reliability of your water quality measurements with HORIBA LAQUAtwin Pocket Testers.

Please note: The salt exchange sensors, both old and new, are not compatible with each other. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants.

How can you tell if you have an older or a new device?

If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for older models.

Manufacturer Part Nr. 3200459866

Dimensions

Height 2,2 cm
Length 14,2 cm
Width 4,5 cm

Weight

Weight 35 g

Other attributes

Brand Horiba
Country of origin JP
Customs tariff number 90279000
Parameter Combined Multiparameter, Salinity
Skip product gallery

We recommend the following

LAQUAtwin salt content tester angled, green and white
Horiba LAQUAtwin Salinity Tester with 2 calibration points and temperature measurement (Salt-22)
Article number: 896060

LAQUAtwin SALT-22: The world’s first pocket-sized salinity meter. Your mobile laboratory – for on-site use: Ideal for water quality testing in aquariums, foodstuffs and many other applications. HORIBAs unique compact meter integrates the electrode, display and sample chamber to enable simple, effective on-site testing through direct measurement with a single drop. Minimum sample volume: 0.3 ml (0.05 ml with sample sheet B) Display of salinity, mV and temperature Up to 2 calibration points Automatic calibration Automatic standard recognition: 0.5 & 5.0% NaCl (standard) Adjustable high and low calibration values Temperature calibration: 5 to 40.0 ºC Automatic stabilisation / automatic hold measurement Automatic switch-off: 30 mins Low battery indicator IP67 rated dust and waterproof Replaceable sensor 400-hour battery life: continuous operation without backlight Material: ABS-epoxy Display: custom (monochrome) digital LCD with backlight Operating conditions: 5 to 40 ºC, 85% or less relative humidity Warranty: 2 years – meter; 6 months – sensor Packaged in a handy carrying case Manufacturer’s item number: 3200689158 Supplied with 0.5% and 5.0% NaCl standards (14 ml each), 5 x Sample Form B, 2 x CR2032 batteries, pipette, instructions and quick guide Additional information We would like to inform you of an upcoming product update for the LAQUAtwin pocket meters. To enhance product safety and prevent infants and young children from accidentally swallowing the batteries, HORIBA will be introducing a new battery cover on all LAQUAtwin pocket-sized analysers. Overview of the product change Change: Battery cover for enhanced safety. Reason: To prevent accidental swallowing of batteries. Production date: from January 2026 in Japan Deliveries to EMEA distribution partners: from March 2026 As this change is currently being rolled out, mixed deliveries of the current and updated versions may occur during the transition phase. Please note: The salt exchange sensors, both old and new, are not compatible with each other. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device variants. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for older models.

€385.00*
Horiba 0.5 % NaCl standard solution, six individual blue bottles
Horiba 0.5% NaCl Standard Solution (514-05)
Article number: 895672

To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No. 3999960112

€48.00*
Horiba 5% NaCl Standard Solution bottle front view with dropper tip, calibration signal clearly visible
Horiba 5.0% NaCl Standard Solution (514-50)
Article number: 895673

To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No. 3999960113

€48.00*
The photo shows 6 bottles of conditioning solution. The bottles are blue with labels.
Horiba Conditioning Solution for Conductivity and Salt Sensors (514-20)
Article number: 895674

To accurately calibrate and maintain the HORIBA LAQUAtwin Pocket Testers, HORIBA provides a special selection of buffer, calibration and standard solutions. A convenient pack size of 6 x 14 ml of these solutions meets the requirements of the pocket testers as only a few drops are needed for calibration. This specific pack size helps to reduce waste and optimize efficiency during regular calibrations. The solutions available cover a variety of measurement ranges, allowing users to select the appropriate solution to suit their individual analysis or measurement needs: pH buffer solutions: Solutions with pH values of 4.01 or 7.00 are available to calibrate the pH measurement. With these buffers it is possible to precisely regulate and control the pH measurement function of the LAQUAtwin Pocket Tester. Conductivity standard solutions: 1413 μS/cm standard solutions ensure that the conductivity measurement of your devices is carried out precisely. NaCl standard solutions: 0.5% or 5.0% NaCl solutions are available for the calibration of salinity measurement. Ion standard solutions: HORIBA provides standard solutions to calibrate ion selective measurements. HORIBA provides standard solutions for sodium, potassium, nitrate and calcium, available in different concentrations: from low (e.g. 150 ppm) to high concentrations (e.g. 5000 ppm). Fluoride ion standard solutions: For the calibration of fluoride measurements, HORIBA offers standard solutions with concentrations of 1 ppm and 10 ppm. TISAB solution: A special solution for use with fluoride ion standard solutions to adjust the ionic strength of the sample for precise fluoride measurements. ORP standard solution: For the calibration of redox measurements (ORP), HORIBA offers a solution with a redox potential of 225 mV. With these special solutions, the HORIBA LAQUAtwin pocket testers always provide accurate and reliable measurement results. The integrity of their measurement data and the lifetime of their devices can be ensured by regular calibration with these specifically formulated solutions. It is of great importance to select the appropriate calibration solution and standard solution to maintain the accuracy of measurements and ensure the reliability of water quality measurements in various applications. Important note regarding compatibility Please note: The replacement sensors, both old and new, are not compatible with one another. Similarly, the conditioning solutions for the old and new versions are not compatible with the respective device models. How can you tell if you have an older or a new device? If your Pocket Tester is marked ‘4-cell’, you have the latest version of this device. In this case, you will need the replacement sensors listed in the cross-selling section, as well as the standard and conditioning solutions. These have been specially optimised for the new Pocket Testers and are not suitable for the older models. Manufacturer Part No.: 3999960114

€48.00*