Spare Parts for TESTOMAT 2000 / ECO / EVO / TITROMAT – Quality for Your Water Analysis Devices
For reliable and long-lasting use of your water analysis devices from the TESTOMAT 2000, ECO, EVO, and TITROMAT series, HeylNeomeris offers a comprehensive range of spare parts. Whether seals, connection components, or plug-in cards – our spare parts are specially matched to these models and ensure optimal performance and easy maintenance.
- Measuring instruments
- Chemistry
- Controls
- Electrodes and sensors
- Dosing technology
- Plant engineering
- Disinfection and Hygiene
- Laboratory & Mobile Measurement Technology
- Accessories
- Training courses
- Service & Company
Filter products
The regulator plug T2000, complete, is a spare part for Testomat 2000®.
Regulator/filter intake, complete, is a spare part for für Testomat® devices: Testomat 2000®/ Testomat® EVO TH/ Testomat ECO®/ Titromat®
Maintenance & Repair Kit for TESTOMAT® / TITROMAT® Comprehensive Maintenance and Repair Kit for Professional Servicing The maintenance and repair kit combines a wide range of spare and wear parts for Testomat® and Titromat® devices. The kit covers all components required for service work on the Testomat device family and the Titromat from Heyl. The kit includes: 10 x O-Ring 20x2 10 x O-Ring 10.82x1.78 5 x O-Ring 4.47x1.78 5 x O-Ring 18x2 EPDM 20 x Flat Gasket 24x2 5 x Inlet Filter Screen 19.5dx25 5 x Flow Regulator Core 2 x Spring for Inlet 15 x Plugs for Measuring Chamber 6 x Fuse, T 0.08A 6 x Fuse, T 0.1A 6 x Fuse, T 0.16A 6 x Fuse, T 0.2A 6 x Fuse, T 0.315A 6 x Fuse, T 1.0A 6 x Fuse M4A 20 x Sight Glass 30x3 3 x Screw Cap with T2000 Insert 4 x Screw M3x40 1 x Suction Hose 1 x Pressure Hose 6 x Various Pipes 1 x Cleaning Brush Set 2 x Plug-In Elbow Connectors 2 x Magnetic Stirring Cores Professional Maintenance and Repair of Testomat® and Titromat® Devices The maintenance and repair kit for TESTOMAT® and TITROMAT® was specifically designed for professional service use. It combines a comprehensive selection of spare and wear parts needed for regular maintenance, servicing, and repairs of the device family. Thanks to its complete equipment, the kit is ideal for service technicians, maintenance staff, and operators who want to minimize downtime and carry out maintenance efficiently on-site. Advantages of the Maintenance & Repair Kit for Service Use The repair kit covers almost all typical wear and spare parts used in the operation of Testomat® and Titromat® analysis devices. From seals and O-rings to fuses, hoses, sight glasses, and cleaning accessories, everything is organized clearly in one kit. This allows for fast troubleshooting, reduces downtime, and ensures consistently high measurement accuracy and operational reliability. At the same time, the kit simplifies spare part storage and supports an economical maintenance strategy. Frequently asked questions Are there any differences between service sets for the Testomat 808 and the Testomat 808 SiO2? Yes, as they do not automatically have the same spare parts. More detailed lists can also be found in the respective operating instructions under ‘Spare parts lists’. What are service sets for? They are designed to enable regular maintenance and minor repairs to be carried out independently. Regular servicing can significantly increase the service life of your Testomat. What does the service set or maintenance kit contain? The exact contents of the service sets and maintenance kits can be seen in the pictures or in the item descriptions listed in the shop. Can individual components also be ordered? Yes, that is possible. Please send us the item numbers or the exact item description by email: vertrieb@heylneomeris.de Can I also order a service set or maintenance kit and have the service carried out by a service partner? Yes, this is possible. Please let us know the exact location of the Testomat device so that we can find the service partner for your region. HeylNeomeris has a Germany-wide service partner network as well as service partners in Austria.
Ribbon cable 10 pole with EMI filter clamp 240 mm, 2 x 5 pol is a spare part for Testomat 2000® / Testomat ECO® / Titromat.
Ribbon cable 26 pol. with ferrite,250 mm, 2 x 13 pol. socket plug, is a spare part for Testomat 2000® / Testomat ECO® / Titromat
Device Screw cap GL32 - with hole is a spare part for 100ml and 500 ml bottles of Testomat 2000® / Testomat ECO® / Testomat® EVO TH / T808 and Titromat.
Screw cap with insert and suction tube for 500 ml bottle complete - T2000/ECO/EVO/Titromat
Screw connector G1/8´´-6 is a spare part for Testomat 2000® / ECO® and Titromat®.
Screw connector T 3/8´´-10 is a spare part for Testomat 2000® / ECO® and Titromat®.
Content: 2 x 40170 sight glass 30x33 x 33777 flat gasket 24x2 EPDM 602 x 33776 O-Ring 18x2 EPDM3 x 11210 Protection plug to measuring chamber T2000 / ECO / EVO TH / EVO TH CAL1 x 40050 Magnetic stirring core
This special service set is designed for the Testomat 2000® PO4. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000 gasket kit 2 30x3 sight glass 1 flow regulator cores 3 stoppers for m. chamber 2 x pump head 1 filter screen for intake 3 different pipes 1 cleaning brush set 2 x tube connection 2 x seal for tube connection 1 x screw cap with insert for 500 ml bottle 1 x screw cap with insert for 100 ml bottle
This special service set is designed for the Testomat 2000® Polymer. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head. The service set includes the following spare parts: 1 T2000 gasket kit 2 30x3 sight glass 1 flow regulator cores 3 stoppers for m. chamber 2 x pump head 1 filter screen for intake 3 different pipes 1 cleaning brush set 2 x tube connection 2 x seal for tube connection 2 x screw cap with insert
Annual Service Set for Testomat® EVO TH, 2000 & ECO / Titromat® Annual Recommended Maintenance Package for High Operational Reliability The annual service set for Testomat 2000®, Testomat ECO®, Titromat®, and Testomat® EVO TH includes all essential wear parts required for yearly maintenance. The set includes: 1 x Seal Kit T2000 2 x Sight Glass 30x3 3 x Disc Plugs 5.3dx5 PE natural 1 x Valve Set for Injection Pump 1 x Inlet Filter 19.5dx25 Recommended Maintenance Package for Annual Service of Your Water Analysis Devices The annual service set for Testomat® EVO TH, Testomat® 2000, Testomat® ECO, and Titromat® contains all essential wear parts that should be replaced as part of the yearly recommended maintenance. It ensures reliable operation and helps maintain measurement accuracy at a consistently high level. Regular replacement of the included components prevents unplanned downtime, allows efficient planning of maintenance intervals, and sustainably increases the operational reliability of the devices. Advantages of the Annual Service Set for Testomat® & Titromat® Devices The annual service set offers a practical, all-in-one solution with all relevant spare parts for yearly maintenance. Wear parts such as seals, sight glasses, disc plugs, and valve components can be replaced quickly without the need for additional spare parts. This reduces downtime, simplifies on-site maintenance processes, and ensures consistently high measurement quality in industrial and commercial water treatment. At the same time, the set supports economical and preventive maintenance of Heyl Testomat® and Titromat® devices. Frequently asked questions Are there any differences between service sets for the Testomat 808 and the Testomat 808 SiO2? Yes, as they do not automatically have the same spare parts. More detailed lists can also be found in the respective operating instructions under ‘Spare parts lists’. What are service sets for? They are designed to enable regular maintenance and minor repairs to be carried out independently. Regular servicing can significantly increase the service life of your Testomat. What does the service set or maintenance kit contain? The exact contents of the service sets and maintenance kits can be seen in the pictures or in the item descriptions listed in the shop. Can individual components also be ordered? Yes, that is possible. Please send us the item numbers or the exact item description by email: vertrieb@heylneomeris.de Can I also order a service set or maintenance kit and have the service carried out by a service partner? Yes, this is possible. Please let us know the exact location of the Testomat device so that we can find the service partner for your region. HeylNeomeris has a Germany-wide service partner network as well as service partners in Austria.
Service Set for Testomat® EVO TH, Testomat® 2000®, Testomat® ECO® & Titromat® Complete Service Set for Regular Professional Maintenance of Your Water Analysis Devices The service set contains all essential spare parts and wear components required for the regular maintenance of your Testomat 2000®, Testomat ECO®, Titromat®, or Testomat® EVO TH devices. The service set includes: 1 x T2000 Seal Kit 2 x Sight Glasses 30x3 1 x Complete Flow Regulator Core 3 x Plugs for Measuring Chamber 1 x Valve Set for Injection Pump 1 x Inlet Filter Screen 19.5dx25 3 x Various Pipes 1 x Cleaning Brush Set Why is Regular Maintenance of Water Analysis Devices Important? Regular maintenance is essential for measurement accuracy, operational reliability, and the lifespan of water analysis devices. Wear parts such as seals, sight glasses, or valves naturally degrade over time due to water, chemicals, and mechanical stress. With a professional service set, you ensure that your Testomat® EVO TH, Testomat® 2000®, Testomat® ECO®, or Titromat® consistently delivers reliable measurement results, prevents unplanned downtime, and allows maintenance intervals to be followed efficiently. Advantages of the Service Set for Testomat® & Titromat® Devices The service set contains all essential spare and wear parts required for comprehensive maintenance. Replacing components on a planned maintenance cycle helps prevent measurement deviations early and maintains the functional reliability of the analysis devices. Additionally, the set reduces organizational effort because all relevant parts are included in a single package. This saves time on procurement, minimizes downtime, and supports economical and safe operation in industrial and commercial water treatment systems. Frequently asked questions Are there any differences between service sets for the Testomat 808 and the Testomat 808 SiO2? Yes, as they do not automatically have the same spare parts. More detailed lists can also be found in the respective operating instructions under ‘Spare parts lists’. What are service sets for? They are designed to enable regular maintenance and minor repairs to be carried out independently. Regular servicing can significantly increase the service life of your Testomat. What does the service set or maintenance kit contain? The exact contents of the service sets and maintenance kits can be seen in the pictures or in the item descriptions listed in the shop. Can individual components also be ordered? Yes, that is possible. Please send us the item numbers or the exact item description by email: vertrieb@heylneomeris.de Can I also order a service set or maintenance kit and have the service carried out by a service partner? Yes, this is possible. Please let us know the exact location of the Testomat device so that we can find the service partner for your region. HeylNeomeris has a Germany-wide service partner network as well as service partners in Austria.
There is a separate service set especially for Testomat® LAB TH, which contains important spare parts. The service set includes the following spare parts: 1 T2000 gasket kit 2 sight glasses 30x3 1 flow regulator core 3 measuring chamber plugs 1 filter screen for intake 5 different pipes 1 cleaning brush set 2 x screw cap with insert for 500 ml bottle
Content: 1 x 40121 inlet connector1 x 40122 outlet connector,PVC1 x 11225 Flow regulator core (1-8 bar)2 x 11216 O-Ring 20x2 (NBR) 1 x 11217 filter strainer for feed 19,5dx251 x 33777 flat gasket 24x2 EPDM 601 x 40153 screw connector G1/4"-61 x 40129 controller plug T2000,cpl.
Content: 1 x #40011 suction hose, cpl.1 x #40016 pressure hose, cpl.1 x #40040 valve set for jet pump
Spare part: Set of valves for Pump DOSIClip®
The sight glass set contains two sight glasses made of Plexiglas and the corresponding seals. Can be used for the Testomat ECO®/ 2000.
Spare part: Sight glass windows 30×3 for measuring chamber of Testomat ECO®, Testomat 2000®, Testomat® 808.
Solenoid valve, 2/2-way for chamber holder of TESTOMAT®2000
Plug-in card for a voltage interface, suitable for Testomat 2000® and Titromat® instruments. Technical Data output voltage: 0/2-10V galvanic isolation: Frequently asked questions What do I need the UK 910 voltage interface for? To pass on measured values as a voltage signal to other systems. What devices is the interface compatible with? Suitable for Testomat 2000® and Titramat® devices. E.g. suitable for Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3, Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2. What signals can the interface output? Tension signals in the range of 0/2 to 10 volts. What does galvanic isolation mean? The connection is electrically disconnected and protects against interference or damage. Is the installation complicated? No, the plug-in card can be easily inserted into the device. What can I use the output signal for? For further processing in control systems or for monitoring measurement values. What advantage does the interface offer in everyday life? It allows for easy integration into existing Testomat devices.