Language in the display
Performance/execution

Product number: 100131
Measurement parameters: Total chlorine | Free chlorine
Measuring range: Total chlorine: (Resolution) 0.00 – 0.99 mg/l (0.01) 1 – 2.5 mg/l (0.1) | Free chlorine: (Resolution): 0.00 – 0.99 mg/l (0.01) 1 – 2.5 mg/l (0.1)
Application: Monitoring of chlorination plants for drinking water | Monitoring of chlorination plants for swimming pools | Provision of protection for reverse osmosis membranes || Controlling of chlorine biocides and conditioning agents
Menu navigation: German, English, French,
Would you like to register the warranty for this product?
Register warranty here
A warranty extension is possible after taking out an indicator subscription.

Leasing Example

155,55 € non-binding
Monthly Rate (60 Rates)

Further rate options by choosing the payment method Leasing

Alternatives to this product

Testomat® LAB CL
Product number: 116106
Pro's
  • Messbereich 0 – 5 mg/l (T2000 hat nur 0 – 2,5 mg/l)
  • Integrierte Datenaufzeichnung (Messwerte sowie Fehlermeldungen) auf SD-Karte
  • Messfunktion als dauerhaft in festen Zeitintervallen oder Messphase*2 programmierbar
Was kann es nicht?
  • Grenzwertrelais
  • Keine Displayanzeige
  • Keine 2 Messstellen
  • Kein AUX Relais
Erforderlicher Leistungsumfang
  • Analyse für freies Chlor oder
  • Gesamtchlor (Festlegung durch
  • gewählten Reagenzsatz)
  • IST-Wert Bestimmung
  • 4-20mA Messwertübertragung
  • Grenzwertrelais
    (nur umsetzbar mittels NeoTecMaster®)
Ergänzende Funktionen
  • Displayanzeige für Messwerte
  • Schutzhaube für IP 65
  • Externe Analysenauslösung (START/STOP-Relais)
  • Parametrierung mittels PC-Software
*2 Nur während dieser Zeit werden Analysen im eingestellten Intervall durchgeführt. Außerhalb der Messphase wartet das Gerät auf ein Startsignal und gibt einen Strom von 4 mA aus. Es können Werte im Bereich von 10 Minuten bis 12 Stunden eingeben werden.

€4,949.30*
Product information "Testomat 2000® CLT"
The Testomat 2000® CLT process photometer is an online analyzer for monitoring the content of total chlorine (CLT) in the range of 0-2.5 mg / L (ppm); switchable to free chlorine in the same range.

Performance profile:
  • Analysis via automatic dosing of three reagents
  • The analysis result is displayed after a reaction time of approx. 1 min. (Measuring time without rinsing time)
  • 2 independently programmable limit contacts for monitoring and control tasks
  • Menu-driven operation and programming via plain text display
  • High-precision titration using a piston dosing pump
  • Analysis initiation:
    • Automatic interval operation
    • (Interval pause adjustable from 0–99 min)
    • External control
    • Dynamic (fatigue-dependent interval operation)
    • Quantity dependent via contact water meter
  • Two independent limits with hysteresis (1, 2 oder 3 bad analyzes) and adjustable switching functions
  • Monitoring of two measuring points (Switching by external solenoid valves)
  • programmable service address
  • Internal error documentation
  • Programmable maintenance interval for maintenance request
Breite: 27 cm
Gewicht: 10,2 kg
Länge: 43 cm, 56 cm
Ursprungsland: DE
Zolltarifnummer: 90278990
Technical specifications
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–45 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 0,3–8 bar
Weight: approx. 9,5 kg
Menu Language: German, English, French
Measuring range: Total chlorine: (Resolution) 0.00 – 0.99 mg/l (0.01) 1 – 2.5 mg/l (0.1) | Free chlorine: (Resolution): 0.00 – 0.99 mg/l (0.01) 1 – 2.5 mg/l (0.1)

We recommend the following reagents and accessories

Testomat 2000® chlorine reagent set T (total chlorine) 2 x 500 ml B & 1 x 200 ml C
Product number: 156235
The bottles of original Testomat 2000® Chlorine Reagent Set T can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content: 2 x 500 ml A, 1 x 400 ml B, 1 x 200 ml C Measuring ranges: Total chlorine: 0,00-0,99 mg/l (Resolution: 0,01 mg/l) 1,0-0-2,5 mg/l (Resolution: 0,1 mg/l)

€325.80*
Testomat 2000® Chlorine Reagent Set T 50 % (total chlorine) 1 x 500 ml A, 1 x 200 ml B, 1 x 100 ml C
Product number: 156237
The bottles of Testomat 2000® Chlorine Reagent Set T 50 % can be used immediately in the Testomat 2000®® CLT, Testomat 2000® CLT Self Clean or Testomat 2000 THCL® without cumbersome filling and refilling. Content:  1 x 500 ml CL2250A 1 x 200 ml CL2250B 1 x 100 ml CL2250C Measuring ranges: Total chlorine: 0.00 - 0.99 mg/l (Resolution: 0.01 mg/l) 1 - 2.5 mg/l (Resolution: 0.1 mg/l) Free chlorine: 0.00 - 0.99 mg/l (Resolution: 0.01 mg/l) 1 - 2.5 mg/l (Resolution: 0.1 mg/l)

€261.40*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€125.10*
Testomat 2000® Reagent CL2250A 500 ml
Product number: 156230
500 ml-bottles of original Testomat 2000® reagent CL 2250 A can be used immediately in the Testomat 2000®® CLF or CLT.    

€98.60*
Testomat 2000® Reagenz CL 2250 B 500 ml
Product number: 156231
500 ml-bottles of original Testomat 2000® reagent CL 2250 B can be used immediately in the Testomat 2000® CLF or CLT.    

€193.20*
Testomat 2000® Reagent CL 2250 C 500 ml
Product number: 156232
The 500 ml-bottles of original Testomat 2000® Reagenz CL 2250 C can be used immediately in the instrument without cumbersome filling and refilling. Measuring ranges: Total chlorine: 0,00-0,99 mg/l (Resolution: 0,01 mg/l) 1,0-0-2,5 mg/l (Resolution: 0,1 mg/l)  

€282.30*
outlet hopper cpl. T2000/ECO
Product number: 40315

€88.20*
Current Interface SK 910
Product number: 270305
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments.   Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation   Usable in following devices: Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3,  Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2  

€246.00*