Measurement parameters: Carbonate hardness
Measuring range: 89,5 – 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)
Application: Alkalinity of open cooling circuits
Menu navigation: German, English, French
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.

Leasing Example

196,03 € non-binding
Monthly Rate (60 Rates)
Prices excl. VAT

Further rate options by choosing the payment method Leasing

Product information "Titromat® KH"
The Titromat® KH is used for the automatic determination and monitoring of the carbonate hardness at high hardness measuring ranges.

The Titromat®-Geräte KH, M1, M2 und TH are based on the technology, the performance profile and technical basic data of the Testomat 2000®.
Application:
  • alkalinity of open cooling circuits

Dimensions

Height 29 cm
Length 56 cm
Width 44 cm

Weight

Weight 11 kg

Other attributes

Country of origin DE
Customs tariff number 90278990
Technical specifications
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Dimensions (W x H x D):     380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa 
Weight: approx. 9,5 kg
Menu Language: German, English, French
Measuring range:Carbonate hardness: 89,5 – 2685 ppm (Resolution: 89,5 ppm) | 35,8 - 1074 ppm (Resolution: 35,8 ppm) 

We recommend our reagents, as well as the following accessories

Titromat® TC 2060 Reagent A 500 ml
Product number: 155176
The 500 ml-bottle of original Titromat® TC 2060 Reagent A can be used immediately in the Titromat® KH without cumbersome filling and refilling. resolution: 2 °dH Measuring range: Carbonate hardness: 89,5 - 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)

€390.56*
Titromat® TC 2060 Reagent B 500 ml
Product number: 155177
The 500 ml-bottle of original Titromat® TC 2060 Reagent B can be used immediately in the Titromat® KH without cumbersome filling and refilling.   resolution: 2 °dH   Measuring range:   Carbonate hardness: 89,5 - 2685 ppm (resolution: 8,9 ppm) 35,8 - 1074 ppm (resolution: 35,8 ppm)  

€390.56*
Titromat TC 2150 reagent A, 500 ml
Product number: 155178
The 500 ml bottles of the original Titromat TC2150 Reagent A can be used immediately without cumbersome decanting into the Titromat KH.

€408.77*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€160.17*
outlet hopper cpl. T2000/ECO
Product number: 40315

€110.19*
Current Interface SK 910
Product number: 270305
Plug-in card for a current interface, suitable for Testomat 2000® and Titromat® instruments.   Technical Data output current: 0-20mA or 4-20mA maximum load: 500 Ohm galvanic isolation   Usable in following devices: Testomat 2000®, Testomat 2000® CAL, Testomat 2000® CLF, Testomat 2000® CLT, Testomat 2000® CrVI, Testomat 2000® DUO, Testomat 2000® Fe, Testomat 2000® SO3,  Testomat 2000® Self clean, Testomat 2000 THCL®, Testomat 2000® CLO2, Testomat 2000® Br2  

€305.95*