JUMO contact resistance thermometer with connection cable and mounting hole, stainless steel protection fitting

Article number: 802085
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "JUMO contact resistance thermometer with connection cable and mounting hole, stainless steel protection fitting "

Surface-Mounted Resistance Thermometer with Pt100 and Tolerance Class B according to DIN EN 60751 with Temperature Range -50 to +260 °C

JUMO Surface-Mounted Resistance Thermometer with PTFE Connection Cable and Mounting Hole, Stainless Steel Protection Fitting, Type: 902550/11-386-1003-1-11-2500/000

The surface-mounted resistance thermometer is suitable for indirect temperature measurement on pipes and other surfaces. Equipped with a Pt100 in a two-wire circuit, PTFE connection cable and robust stainless steel design, this version is especially suitable for quickly mounted surface measurements from -50 to +260 °C.

This version is intended for temperature measurements on surfaces where the sensor is mounted externally and the measuring point should not be mechanically modified. The surface-mounted resistance thermometer is therefore particularly suitable for closed pipe systems as well as round or flat surfaces where temperatures need to be recorded quickly and easily.

Technical Data

  • Version: Surface-mounted resistance thermometer with mounting hole
  • Protection fitting: Stainless steel
  • Sensor insert: 1 × Pt100
  • Circuit type: Two-wire circuit
  • Tolerance class: Class B according to DIN EN 60751
  • Connection cable: PTFE
  • Temperature range: -50 to +260 °C
  • Connection cable end: Ferrules according to DIN 46228 Part 4
  • Connection cable length: 2500 mm
  • Type extension: none

Advantages and Technical Features of the Surface-Mounted Resistance Thermometer

  • no mechanical processing of the measuring point required
  • well suited for closed pipe systems
  • fast and uncomplicated installation
  • indirect temperature measurement without direct contact with the medium
  • PTFE connection cable for temperatures up to +260 °C
  • practical solution for retrofittable surface measurements

Unlike insertion or screw-in solutions, the measurement is performed indirectly via the surface. This is particularly useful where no modifications to the system are desired or where the temperature needs to be recorded without contact with the medium. Installation can be carried out using tension bands or hose clamps and is therefore simple to implement.

A Pt100 in a two-wire circuit is used for temperature measurement. Combined with the PTFE connection cable, this version is designed for temperatures from -50 to +260 °C. This also makes it suitable for applications where higher temperatures occur on the surface. The 2500 mm long connection cable provides sufficient flexibility for integration into the system.

The stainless steel protection fitting makes this version particularly suitable for applications requiring a robust and durable design. At the same time, the construction ensures efficient heat transfer from the measuring point to the sensor. Due to the low thermal mass, the surface temperature can be measured quickly and reliably without flow, pressure or chemical influences from the medium directly affecting the measurement.

In the case of larger temperature differences between the measured medium and the surrounding environment, it should be noted that these may affect the measurement result. In such cases, additional insulation may be beneficial. Thermal paste can also optionally be used to further improve heat transfer at the measuring point.

Typical Applications

  • surface measurement on closed pipe systems
  • temperature measurement on round pipes
  • temperature measurement on flat components
  • retrofitting existing systems

Dimensions

Height 0,7 cm
Length 20 cm
Width 21,5 cm

Weight

Weight 18 g

Other attributes

Country of origin DE
Customs tariff number 90251900
Messeinsatz 1x Pt 100 Zweileiterschaltung
Temperaturbereich -50°C ... +260°C
Technical data
Technical specifications Description
Connection Cable ends tinned, available with ferrule terminals, plug-in sleeves or multi-pin connectors
connection cable
  • Silicone, ambient temperature -50 to +180 °C
  • PTFE, ambient temperature -190 to +260 °C
  • Kapton, ambient temperature -50 to +260 °C
Terminal box
  • Basic model 902554/41 and 902554/42: PC plastic housing, colour: silver-grey/blue
  • Basic model 902554/44: PC plastic housing, colour: white
  • Connection via screw terminals; basic model 902554/44 is available with spring-loaded terminals as an option when selected without a transducer
protective tube Stainless steel 1.4571, aluminium, plastic
Gauge insert Pt100 temperature sensor, DIN EN 60751, Class B, two-wire circuit
Transducer Optional for base model 902554/44: analogue transmitter, 4 to 20 mA or 0 to 10 V
Transmitter
Characteristic Output 4 to 20 mA Output 0 to 10 V
Input
Measuring input Pt100 (DIN EN 60751) Pt100 (DIN EN 60751)
Sensor current ≤0,5 mA ≤0,5 mA
Measuring rate Continuous measurement, due to analogue signal path. Continuous measurement, due to analogue signal path.
Measuring circuit monitoring
Underrange (measuring range underrun) decreasing down to ≤ 3,6 mA 0 V
Overrange (measuring range overrun) rising to ≥ 22 up to < 28 mA
(typically 24 mA)
rising to ≥ 11 up to < 14 V
(typically 12 V)
Sensor short circuit ≤ 3,6 mA 0 V
Sensor and cable break ≥ 22 to < 28 mA (typically 24 mA) ≥ 11 to < 14 V (typically 12 V)
Output
Output signal Pulsed direct current 4 to 20 mA DC voltage 0 to 10 V
Transfer behaviour temperature-linear temperature-linear
Transmission accuracy ≤ ±0,1 % ≤ ±0,2 %
Attenuation of the residual ripple of a 24 V power supply, amplitude 10 V / 50 Hz, load 470 Ω / 10 MΩ load 37 dB 40 dB
Load (Rb) Rb = (Ub - 7,5 V) ÷ 22 mA -
Load effect ≤ ±0,02 % / 100 Ωa -
Load / Load Influence - ≥ 10 kΩ / ≤ ±0,1 %
Settling time after temperature change ≤ 10 ms ≤ 10 ms
Calibration conditions DC 24 V / approx. 22 °C DC 24 V / approx. 22 °C
Calibration accuracy ≤ ±0,2 %a,b or ≤ ±0,2 K ≤ ±0,2 %a,b or ≤ ±0,2 K
Overall sensor accuracy/Calibration ±0,4 K (typical) at 20 °C / 24 V
Power supply
±0,4 K (typical) at 20 °C / 24 V
Power supply
Power supply
Power supply (Ub) DC 7,5 at 30 V DC 15 at 30 V
Reverse polarity protection yes yes
Power supply influence ≤ ±0,01 %/V Deviation from 24 Va ≤ ±0,01 %/V Deviation from 24 Va
Environmental influences
Operating temperature range -40 to +85 °C -40 to +85 °C
Lagertemperaturbereich -40 to +100 °C -40 to +100 °C
Temperature influence ≤ ±0,01 %/K deviation from 22 °C a ≤ ±0,01 %/K deviation from 22 °C a
Climatic resistance
similar to DIN EN 60654 class C1
relative humidity ≤ 95% annual average without condensation relative humidity ≤ 95% annual average without condensation
EMC emissions and immunity EN 61326 class B, industrial requirements EN 61326 class B, industrial requirements

a All specifications refer to the full-scale value of 20 mA.
b The higher value applies.

Approvals / certifications
Certification marks Testing body Certificate / test number Basis for audit Applies to
SIL QUALIFIED
PL QUALIFIED
Type suffix 058
in conjunction with the manufacturer's declaration