Glass electrodes
- Water Analyzers
- Liquid chemistry
- Controls
-
Electrodes and sensors
- Manufacturer
- Parameter
-
Typical application (selection guide for pH / ORP)
- Water and process measurement technology
- Waste water, heavily contaminated media, chemical industry, suspensions, lacquers
- High temperature and sterilisation applications
- Swimming bath and pool
- Cooling tower
- Power plants, waste incineration plants, galvanisation
- Aquaristics, marine aquaristics
- Rainwater, pond and surface water, greenhouse
- Drinking water monitoring and treatment
- Accessories
- Hand-held measuring instruments and analysis cases
- Laboratory Benchtop Meters
- NeoTec World
- Permeate
- Clinical Solutions
- Seminars & Webinars
- Ozone and UV technology
- Dosing pumps
- Gas Measuring Instruments
- Hygiene and Disinfection
- Water Meters
- Accessories
- Blog
Filter products
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values low maintenance and robustextended service lifeSelected version:without temperature sensorS8 N-srew head Pg13,5, PPS materialPTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)Hole diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-11-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values low maintenance and robustextended service lifeSelected version:PT100 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/840Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
High-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature probedifferent installation lengthsspecial types on request
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivitySelected version:Basic type: Glass shaftActive part: Platinum capDiaphragm: PTFE ringElectrical connection to electrode: screw head Pg13.5 (S8)Insertion length: 120mm (standard)Extra codes: Salt reserveOrder code: 201025/51-22-04-22-120/837