JUMO T-piece DN32, PVC (incl. union nut, O-ring, glue-in bushing)

Product number: 800348
Quantity Unit price
To 4
€101.50*
To 9
€96.43*
To 14
€91.35*
To 19
€86.28*
From 20
€84.25*
Please log in to receive your conditions.

Available in 5 days, delivery time 1-2 days

Version

Product number: 800348
GTIN: 4260682389152
Our comment: For JUMO ecoLine CR-PVC 2-electrode conductivity sensor
Offer as PDF  
Login for addressed offer
The entered number of pieces will be taken into account when creating the offer.
Product information "JUMO T-piece DN32, PVC (incl. union nut, O-ring, glue-in bushing)"

Dimensions

Weight

Other attributes

Customs tariff number 90279000

Recommended accessories

JUMO ecoLine CR-PVC, K=0.1, PT100, screw-in thread G 3/4" A, PVC body, cell material stainless steel 1.4571
Product number: 800344
Basic type: ecoLine CR-PVC - Conductive 2-electrode conductivity sensor | Body material: PVC | Cell constant: C = 0.1 (measuring range 0.1 ... 1.0 mS/cm) | Cell material: Stainless steel 1.4571 | Electrical connection: Device plug according to DIN EN 175301-803 (Hierschmann plug) | Measuring resistor (temperature sensor): PT100 | Process connection: Screw-in thread G 3/4" A
2-electrode principleproven versions for industrial use measuring ranges 0 ... 1 mS/cm (K = 0.1) or 0.01 ... 15 mS/cm (K = 1.0) temperature range up to 55 °C, maximum pressure up to 6 bar at 25 °C JUMO ecoLine CR-PVC conductive 2-electrode conductivity sensorBrief description: Conductivity sensors of the 202923 series are used, for example, in general water technology, cooling and air-conditioning systems, drinking and bathing water, or in industrial rinsing and process water circuits. The body material PVC limits the application to medium temperatures up to 55 °C. Two versions with cell constants K = 0.1 or 1.0 are available. Versions with the common thread sizes G 3/4" or G 1" or a plug-in version are available for installation. The plug-in version is used, for example, with the matching PVC tees in nominal sizes DN 25, 32 and 40 and allows the sensor to be quickly dismantled for cleaning or maintenance. The electrical connection is made either via a detachable device plug or via a fixed cable connection. The overall construction and the parts in contact with the medium are physiologically harmless. The electrode material is stainless steel (K = 0.1) or special graphite (K = 1.0). The optionally integrable temperature sensor allows simultaneous recording of the medium temperature for temperature compensation in downstream measuring amplifiers.Stainless steel variant K = 0.1 The sensor has 3 metallic pin electrodes. The two outer pins are electrically connected and form one pole of the 2-electrode conductivity sensor. The counter electrode is the middle stainless steel pin. This design achieves very high measurement precision with low stray fields. A temperature sensor can be integrated in the middle pin. Graphite variant K = 1.0 For physical reasons, special graphite is used as the electrode material for higher conductance values. The two graphite electrodes are completely integrated in the electrode shaft. The optional temperature sensor is located in a stainless steel sleeve that is immersed in the measured medium. Operating principleThe sensors of the 202923 series are 2-electrode conductivity sensors. An AC voltage is applied to them by the transmitter. The current flowing across the liquid and the electrodes is determined by the conductivity of the liquid

From €267.09*
JUMO ecoLine CR-PVC, K=0.1, PT100, step collar PVC Ø32/DN25, PVC body, cell material stainless steel 1.4571
Product number: 800345
Basic type: ecoLine CR-PVC - Conductive 2-electrode conductivity sensor | Body material: PVC | Cell constant: C = 0.1 (measuring range 0.1 ... 1.0 mS/cm) | Cell material: Stainless steel 1.4571 | Electrical connection: Device plug according to DIN EN 175301-803 (Hierschmann plug) | Measuring resistor (temperature sensor): PT100 | Process connection: PVC step collar Ø 32/DN25 (supplied without union nut)
2-electrode principleproven versions for industrial use measuring ranges 0 ... 1 mS/cm (K = 0.1) or 0.01 ... 15 mS/cm (K = 1.0) temperature range up to 55 °C, maximum pressure up to 6 bar at 25 °C JUMO ecoLine CR-PVC conductive 2-electrode conductivity sensorBrief description: Conductivity sensors of the 202923 series are used, for example, in general water technology, cooling and air-conditioning systems, drinking and bathing water, or in industrial rinsing and process water circuits. The body material PVC limits the application to medium temperatures up to 55 °C. Two versions with cell constants K = 0.1 or 1.0 are available. Versions with the common thread sizes G 3/4" or G 1" or a plug-in version are available for installation. The plug-in version is used, for example, with the matching PVC tees in nominal sizes DN 25, 32 and 40 and allows the sensor to be quickly dismantled for cleaning or maintenance. The electrical connection is made either via a detachable device plug or via a fixed cable connection. The overall construction and the parts in contact with the medium are physiologically harmless. The electrode material is stainless steel (K = 0.1) or special graphite (K = 1.0). The optionally integrable temperature sensor allows simultaneous recording of the medium temperature for temperature compensation in downstream measuring amplifiers.Stainless steel variant K = 0.1 The sensor has 3 metallic pin electrodes. The two outer pins are electrically connected and form one pole of the 2-electrode conductivity sensor. The counter electrode is the middle stainless steel pin. This design achieves very high measurement precision with low stray fields. A temperature sensor can be integrated in the middle pin. Graphite variant K = 1.0 For physical reasons, special graphite is used as the electrode material for higher conductance values. The two graphite electrodes are completely integrated in the electrode shaft. The optional temperature sensor is located in a stainless steel sleeve that is immersed in the measured medium. Operating principleThe sensors of the 202923 series are 2-electrode conductivity sensors. An AC voltage is applied to them by the transmitter. The current flowing across the liquid and the electrodes is determined by the conductivity of the liquid

From €283.78*
JUMO ecoLine CR-PVC, K=1.0, PT100, step collar PVC Ø32/DN25, PVC body, cell material graphite
Product number: 800346
Basic type: ecoLine CR-PVC - Conductive 2-electrode conductivity sensor | Body material: PVC | Cell constant: C = 1.0 (measuring range 0.01 ... 15 mS/cm) | Cell material: Graphite | Electrical connection: Device plug according to DIN EN 175301-803 (Hierschmann plug) | Measuring resistor (temperature sensor): PT100 | Process connection: PVC step collar Ø 32/DN25 (supplied without union nut)
2-electrode principleproven versions for industrial use measuring ranges 0 ... 1 mS/cm (K = 0.1) or 0.01 ... 15 mS/cm (K = 1.0) temperature range up to 55 °C, maximum pressure up to 6 bar at 25 °C JUMO ecoLine CR-PVC conductive 2-electrode conductivity sensorBrief description: Conductivity sensors of the 202923 series are used, for example, in general water technology, cooling and air-conditioning systems, drinking and bathing water, or in industrial rinsing and process water circuits. The body material PVC limits the application to medium temperatures up to 55 °C. Two versions with cell constants K = 0.1 or 1.0 are available. Versions with the common thread sizes G 3/4" or G 1" or a plug-in version are available for installation. The plug-in version is used, for example, with the matching PVC tees in nominal sizes DN 25, 32 and 40 and allows the sensor to be quickly dismantled for cleaning or maintenance. The electrical connection is made either via a detachable device plug or via a fixed cable connection. The overall construction and the parts in contact with the medium are physiologically harmless. The electrode material is stainless steel (K = 0.1) or special graphite (K = 1.0). The optionally integrable temperature sensor allows simultaneous recording of the medium temperature for temperature compensation in downstream measuring amplifiers.Stainless steel variant K = 0.1 The sensor has 3 metallic pin electrodes. The two outer pins are electrically connected and form one pole of the 2-electrode conductivity sensor. The counter electrode is the middle stainless steel pin. This design achieves very high measurement precision with low stray fields. A temperature sensor can be integrated in the middle pin. Graphite variant K = 1.0 For physical reasons, special graphite is used as the electrode material for higher conductance values. The two graphite electrodes are completely integrated in the electrode shaft. The optional temperature sensor is located in a stainless steel sleeve that is immersed in the measured medium. Operating principleThe sensors of the 202923 series are 2-electrode conductivity sensors. An AC voltage is applied to them by the transmitter. The current flowing across the liquid and the electrodes is determined by the conductivity of the liquid

From €292.08*
JUMO 25 meter connection cable (4-wire + shield)
Product number: 800351
Cable length: 25 Meter

From €100.43*
JUMO 50 meter connection cable (4-wire + shield)
Product number: 800352
Cable length: 50 Meter

From €191.48*